Permit Application Status

PRRES20131165


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20131165
Building Permit - Residential
Certificate of Occupancy
JOHN KNOX VILLAGE
NEW 3 OR 4 FAMILY
NEW 3PLEX - REPLACING 2 DUPLEX
06/11/2013
11/15/2013
05/01/2015
Locations
Contacts
LARRY HARKRADER CONSTRUCTION, Address:401 NW MURRAY RD, Phone:(816) 607-7191  
AFC HEATING AND COOLING, Address:824 NW MAIN ST , Phone:(816) 347-8388  
S & L ELECTRIC INC, Address:1301 S POWELL, Phone:(816) 796-6859  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
JOHN KNOX VILLAGE, Address:400 NW MURRAY RD  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 06/13/2013 07/02/2013
Gene Williams, P.E.
Corrective Action Required
06/13/2013

encroachment into an existing easement
Plot Plan Review (P&D) Approved 06/17/2013 07/01/2013
Jennifer Thompson
Residential Plan Review Approved 06/13/2013 06/21/2013
Codes Admin
Plot Plan Review (P&D) Rejected 06/13/2013 06/13/2013
Jennifer Thompson
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New 3 or 4 Family $1,465.52 $1,465.52 Paid 11/15/2013
$1,465.52
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/21/2014 (11:30) 3/21/2014 at 12:00 AM 03/21/2014
Water Service Inspection - R Partial 4/11/2014 (11:15) 4/11/2014 at 12:00 AM 04/11/2014
Misc
Partial Correction
04/11/2014
OK TO COVER WHEN READY WATER SERVICE LINE INSTALLATION FROM BUILDING ENTRY TO: STUB @ UNIT C METER LOCATION;
Sewer Service Inspection - R Passed 4/11/2014 (11:15) 4/11/2014 at 12:00 AM 04/11/2014
Water Service Inspection - R Passed 4/11/2014 (1:45) 4/11/2014 at 12:00 AM 04/11/2014
Misc
Resolved
04/11/2014
OK TO COVER WHEN READY WATER SERVICE LINE INSTALLATION FROM BUILDING ENTRY TO: STUB @ UNIT C METER LOCATION;
Underslab Plumbing Inspection - Residential Passed 4/14/2014 4/14/2014 at 12:00 AM 04/14/2014
Miscellaneous Inspection Passed 4/14/2014 at 12:00 AM 04/14/2014
All Rough Inspection - Residential Failed 7/1/2014 7/1/2014 at 12:00 AM 07/01/2014
Misc
Corrective Action Required
07/01/2014
IPC 305.8; IRC P2603 PROTECTION FROM PENETRATION OF PVC / ABS / PEX / COPPER PLUMBING PIPE LESS THAN 1-1/2" FROM FACE OF FRAMING TO RECEIVE SCREWED OR NAILED COVERING: PROTECT PIPE WITH MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES. CHECK ALL.
Misc
Corrective Action Required
07/01/2014
IRC E3702 PROTECTION OF NM ELECT CABLE AND SERVICE ENTRANCE CABLE BORED THROUGH FRAMING WITH EDGE OF HOLE <1-1/4" FROM FACE OF STUD/PLATE: INSTALL MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES TO PROTECT NON-METALLIC CABLE. EXAMPLES: MECHANICAL ROOM; SW CLOSET
Misc
Corrective Action Required
07/01/2014
NEC 334 SECURING OF NM ELECTRICAL CABLE: SECURE WITHIN 12" OF ENTRY TO SERVICE PANEL
All Rough Inspection - Residential Partial 7/2/2014 at 12:00 AM 07/02/2014
Misc
Resolved
07/02/2014
IPC 305.8; IRC P2603 PROTECTION FROM PENETRATION OF PVC / ABS / PEX / COPPER PLUMBING PIPE LESS THAN 1-1/2" FROM FACE OF FRAMING TO RECEIVE SCREWED OR NAILED COVERING: PROTECT PIPE WITH MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES. CHECK ALL.
Misc
Resolved
07/02/2014
IRC E3702 PROTECTION OF NM ELECT CABLE AND SERVICE ENTRANCE CABLE BORED THROUGH FRAMING WITH EDGE OF HOLE <1-1/4" FROM FACE OF STUD/PLATE: INSTALL MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES TO PROTECT NON-METALLIC CABLE. EXAMPLES: MECHANICAL ROOM; SW CLOSET
Misc
Resolved
07/02/2014
NEC 334 SECURING OF NM ELECTRICAL CABLE: SECURE WITHIN 12" OF ENTRY TO SERVICE PANEL
Misc
Corrective Action Required
07/02/2014
OK TO COVER IN-WALL AND ABOVE-CEILING AT UNIT(S): "A";
All Rough Inspection - Residential Partial 7/17/2014 7/17/2014 at 12:00 AM 07/17/2014
Misc
Partial Correction
07/17/2014
OK TO COVER IN-WALL AND ABOVE-CEILING AT UNIT(S): A; B
All Rough Inspection - Residential Partial 7/23/2014 7/23/2014 at 12:00 AM 07/23/2014
Misc
Partial Correction
07/17/2014
OK TO COVER IN-WALL AND ABOVE-CEILING AT UNIT(S): A; B; C AFTER BA VENT FAN IS DUCTED CRAWL SPACES TO BE INSPECTED AT OR BEFORE FINAL INSPECTION.
Gas Piping Inspection - Residential Partial 8/14/2014 8/14/2014 at 12:00 AM 08/14/2014
Misc
Partial Correction
08/14/2014
PRESSURE TEST OF GAS FEEDER PIPING TO UNITS: A: NOT MAINTAINING PRESSURE B: APPEARS TO BE LOSING PRESSURE - CHECK C: HELD >10 PSI PRESSURE STEADY FOR >10 MIN
Gas Piping Inspection - Residential Partial 8/19/2014 8/19/2014 at 12:00 AM 08/19/2014
Misc
Partial Correction
08/14/2014
PRESSURE TEST OF GAS FEEDER PIPING TO UNITS: A: HELD >10 PSI PRESSURE STEADY FOR >10 MIN B: SHOWING ONLY 2PSI PRESSURE C: HELD >10 PSI PRESSURE STEADY FOR >10 MIN
Gas Piping Inspection - Residential Passed 8/21/2014 8/21/2014 at 12:00 AM 08/21/2014
Misc
Resolved
08/21/2014
PRESSURE TEST OF GAS FEEDER PIPING TO UNITS: A: HELD >10 PSI PRESSURE STEADY FOR >10 MIN B: HELD >10 PSI PRESSURE STEADY FOR >10 MIN C: HELD >10 PSI PRESSURE STEADY FOR >10 MIN
Electrical Service Inspection Failed 8/21/2014 at 12:00 AM 08/21/2014
Misc
Corrective Action Required
08/21/2014
NEC 250.92B; IRC E3510.1. BONDING OF SERVICE ENCLOSURES & EQUIPMENT: NON-METTALIC NIPPLE AT METER ENCLOSURE PRODUCES DISONTINUITY. MAY RUN SEPARATE BONDING CONDUCTOR LUGGED INSIDE METER ENCLOSURE AND WIRING TROUGH.
Electrical Service Inspection Passed 8/22/2014 8/22/2014 at 12:00 AM 08/22/2014
Misc
Resolved
08/22/2014
NEC 250.92B; IRC E3510.1. BONDING OF SERVICE ENCLOSURES & EQUIPMENT: NON-METTALIC NIPPLE AT METER ENCLOSURE PRODUCES DISONTINUITY. MAY RUN SEPARATE BONDING CONDUCTOR LUGGED INSIDE METER ENCLOSURE AND WIRING TROUGH.
Occupancy Inspection - Codes Residential Failed 9/26/2014 9/26/2014 at 12:00 AM 09/26/2014
Misc
Corrective Action Required
09/26/2014
SECURE PEX TUBING TERMINATIONS AGAINST TORQUE WHEREVER CENTER OF VALVE IS >3" FROM PENETRATION THROUGH CABINET BASE OR BACK.
Misc
Corrective Action Required
09/26/2014
APPARENT HOT-NEUTRAL REVERSE AT DISPOSAL RECEPTACLE AT UNIT "C"
Misc
Corrective Action Required
09/26/2014
UNIT B: INTERNAL BEND DIAMETER OF GAS CONNECTOR UNDER FIREPLACE IS SMALLER THAN MINIMUM 1-1/2" ALLOWED BY MANUFACTURER (SEE YELLOW TAG THEREON). REPLACE -- DO NOT RE-BEND
Occupancy Inspection - Codes Residential Temporary C of O 9/29/2014 9/29/2014 at 12:00 AM 09/29/2014
Misc
Resolved
09/29/2014
SECURE PEX TUBING TERMINATIONS AGAINST TORQUE WHEREVER CENTER OF VALVE IS >3" FROM PENETRATION THROUGH CABINET BASE OR BACK.
Misc
Resolved
09/29/2014
APPARENT HOT-NEUTRAL REVERSE AT DISPOSAL RECEPTACLE AT UNIT "C"
Misc
Resolved
09/29/2014
UNIT B: INTERNAL BEND DIAMETER OF GAS CONNECTOR UNDER FIREPLACE IS SMALLER THAN MINIMUM 1-1/2" ALLOWED BY MANUFACTURER (SEE YELLOW TAG THEREON). REPLACE -- DO NOT RE-BEND
Occupancy Inspection - Codes Residential Temporary C of O 9/29/2014 at 12:00 AM 09/29/2014
All Rough Inspection - Residential Passed 7/23/2014 at 12:00 AM 09/29/2014
Misc
Resolved
09/29/2014
OK TO COVER IN-WALL AND ABOVE-CEILING AT UNIT(S): A; B; C AFTER BA VENT FAN IS DUCTED CRAWL SPACES TO BE INSPECTED AT OR BEFORE FINAL INSPECTION.
Occupancy Inspection - Codes Residential Temporary C of O 9/30/2014 at 12:00 AM 09/30/2014
Misc
Partial Correction
09/30/2014
EXTERIOR AND FINISH SITEWORK SUBJECT TO APPROVAL WHEN COMPLETED.
Misc
Corrective Action Required
09/30/2014
CRAWL SPACES YET TO BE INSPECTED
Occupancy Inspection - Codes Residential Temporary C of O 10/9/2014 at 12:00 AM 10/09/2014
Misc
Partial Correction
09/30/2014
EXTERIOR AND FINISH SITEWORK SUBJECT TO APPROVAL WHEN COMPLETED.
Plot Plan Inspection Passed 10/16/2014 at 12:00 AM 10/16/2014
Occupancy Inspection - Codes Residential Not Ready 10/16/2014 at 12:00 AM 10/16/2014
Misc
Partial Correction
10/09/2014
EXTERIOR AND FINISH SITEWORK SUBJECT TO APPROVAL WHEN COMPLETED.
Misc
Corrective Action Required
10/16/2014
CRAWL SPACES: SOME PEDESTAL COLUMN BASE PLATES NOT SECURED TO FOOTING. CHECK ALL.
Misc
Corrective Action Required
10/16/2014
CRAWL SPACES: FLOOR INSULATION FALLING OUT OF JOIST CAVITIES AT SOME LOCATIONS. CHECK ALL.
Misc
Corrective Action Required
10/16/2014
CRAWL SPACES: CONDENSATE DRAIN PIPE BOTTOMS NOT SECURED TO DRAIN GRATES. CHECK ALL.
Misc
Corrective Action Required
10/16/2014
CRAWL SPACE @ UNIT "C": SOUTH END OF WEST WIDE FLANGE BEAM NOT BEARING ON SHIM. 3/16" GAP BETWEEN.
Misc
Corrective Action Required
10/16/2014
CRAWL SPACE @ UNIT "B": TAPE AT HVAC DUCT INSULATION JOINTS IS FALLING OFF AT SEVERAL LOCATIONS. SEAL ALL JOINTS AND GAPS.
Occupancy Inspection - Codes Residential Temporary C of O 10/20/2014 at 12:00 AM 10/20/2014
Misc
Partial Correction
10/16/2014
EXTERIOR AND FINISH SITEWORK SUBJECT TO APPROVAL WHEN COMPLETED.
Misc
Corrective Action Required
10/16/2014
CRAWL SPACES: SOME PEDESTAL COLUMN BASE PLATES NOT SECURED TO FOOTING. CHECK ALL.
Misc
Corrective Action Required
10/16/2014
CRAWL SPACES: FLOOR INSULATION FALLING OUT OF JOIST CAVITIES AT SOME LOCATIONS. CHECK ALL.
Misc
Corrective Action Required
10/16/2014
CRAWL SPACES: CONDENSATE DRAIN PIPE BOTTOMS NOT SECURED TO DRAIN GRATES. CHECK ALL.
Misc
Corrective Action Required
10/16/2014
CRAWL SPACE @ UNIT "C": SOUTH END OF WEST WIDE FLANGE BEAM NOT BEARING ON SHIM. 3/16" GAP BETWEEN.
Misc
Corrective Action Required
10/16/2014
CRAWL SPACE @ UNIT "B": TAPE AT HVAC DUCT INSULATION JOINTS IS FALLING OFF AT SEVERAL LOCATIONS. SEAL ALL JOINTS AND GAPS.
Occupancy Inspection - Codes Residential Temporary C of O 12/3/2014 12/3/2014 at 12:00 AM 12/03/2014
Misc
Partial Correction
10/20/2014
FINISH SITEWORK AT WEST SIDE AND NORTH END SUBJECT TO APPROVAL WHEN COMPLETED. VEGETATION YET TO BE ESTABLISHED. THROUGHOUT TEMPORARY OCCUPANCY PERIOD ENSURE NO EROSION TO ADJACENT PROPERTY OR TO STREET/STORM INLETS.
Misc
Resolved
12/03/2014
CRAWL SPACES: SOME PEDESTAL COLUMN BASE PLATES NOT SECURED TO FOOTING. CHECK ALL.
Misc
Resolved
12/03/2014
CRAWL SPACES: FLOOR INSULATION FALLING OUT OF JOIST CAVITIES AT SOME LOCATIONS. CHECK ALL.
Misc
Resolved
12/03/2014
CRAWL SPACES: CONDENSATE DRAIN PIPE BOTTOMS NOT SECURED TO DRAIN GRATES. CHECK ALL.
Misc
Resolved
12/03/2014
CRAWL SPACE @ UNIT "C": SOUTH END OF WEST WIDE FLANGE BEAM NOT BEARING ON SHIM. 3/16" GAP BETWEEN.
Misc
Resolved
12/03/2014
CRAWL SPACE @ UNIT "B": TAPE AT HVAC DUCT INSULATION JOINTS IS FALLING OFF AT SEVERAL LOCATIONS. SEAL ALL JOINTS AND GAPS.
Occupancy Inspection - Codes Residential Temporary C of O 2/19/2015 at 12:00 AM 02/19/2015
Misc
Partial Correction
02/11/2015
VEGETATION YET TO BE ESTABLISHED AT WEST SIDE AND NORTH END OF LOT WHERE GRADES HAVE BEEN MODIFIED FOR DRAINAGE. THROUGHOUT TEMPORARY OCCUPANCY PERIOD ENSURE NO EROSION TO ADJACENT PROPERTY OR TO STREET/STORM INLETS.
Occupancy Inspection - Codes Residential Full C of O 5/1/2015 5/1/2015 at 12:00 AM 05/01/2015
Misc
Resolved
05/01/2015
VEGETATION YET TO BE ESTABLISHED AT WEST SIDE AND NORTH END OF LOT WHERE GRADES HAVE BEEN MODIFIED FOR DRAINAGE. THROUGHOUT TEMPORARY OCCUPANCY PERIOD ENSURE NO EROSION TO ADJACENT PROPERTY OR TO STREET/STORM INLETS.
Documents & Images
Date Uploaded File Type Document Name
11/15/2013 Letter Codes Building Permit
03/21/2014 Letter Inspection Summary
04/11/2014 Letter Inspection Summary
04/11/2014 Letter Inspection Summary
04/14/2014 Letter Inspection Summary
07/01/2014 Letter Inspection Summary
07/02/2014 Letter Inspection Summary
07/17/2014 Letter Inspection Summary
07/23/2014 Letter Inspection Summary
08/14/2014 Letter Inspection Summary
08/19/2014 Letter Inspection Summary
08/21/2014 Letter Inspection Summary
08/22/2014 Letter Inspection Summary
09/26/2014 Letter Inspection Summary
09/29/2014 Letter Codes Temporary Certificate of Occupancy
09/29/2014 Letter Codes Temporary Certificate of Occupancy
09/30/2014 Letter Codes Temporary Certificate of Occupancy
10/09/2014 Letter Codes Temporary Certificate of Occupancy
10/16/2014 Letter Inspection Summary
10/20/2014 Letter Codes Temporary Certificate of Occupancy
12/03/2014 Letter Codes Temporary Certificate of Occupancy
02/19/2015 Letter Codes Temporary Certificate of Occupancy
03/24/2015 Letter Inspection Summary
05/01/2015 Letter Field Certificate of Occupancy
05/04/2015 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home