Permit Application Status

PRCOM20251416


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20251416
Building Permit - Commercial
Issued
NEW MULTI-FAMILY
THE REUNION AT BLACKWELL - BUILDING 1, TYPE A 4PLEX PLAN REVIEW COMPLETED UNDER PRCOM20250089
04/09/2025
06/30/2025
Locations
Contacts
Avital Homes, LLC, Address:7500 W 151st Street, #23100, Phone:(816) 914-7128  
RED DOG ELECTRIC SERVICES, Address:PO BOX 1, Phone:(913) 208-4816  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
COLLINS WEBB ARCHITECTURE LLC, Address:307 SW MARKET ST, Unit A, Phone:(816) 249-2270  
Doug Jenson - Avital Homes, Phone:(816) 266-0685  
Reviews
Review Type Outcome Est. Completion Date Completed
Final Development Plan Review Approved 04/23/2025 04/09/2025
Mike Weisenborn
Building Plan Review Approved with Conditions 04/14/2025 03/31/2025
Mike Weisenborn
Miscellaneous Correction
Corrective Action Required
04/03/2025

Foundation and underlsab plumbing only released at this time. Substantial completion on the santiary and water before private connections can be made. Full access and live hydrants required prior to release of vertical construction.
Licensed Contractors Approved 04/14/2025 03/31/2025
Mike Weisenborn
Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $10,595.00 $10,595.00 Paid 06/30/2025
Water Meter Fee $1,066.76 $1,066.76 Paid 06/30/2025
Residential Excise Tax Fee $2,480.64 $2,480.64 Paid 06/30/2025
Valuation Fee for New 3 or 4 Family $4,009.46 $4,009.46 Paid 06/30/2025
Sanitary Sewer Development Fee $6,101.00 $6,101.00 Paid 06/30/2025
Right of Way Permit Fee $85.00 $85.00 Paid 06/30/2025
Outstanding Fees Amount Paid Owing Date Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid


$225.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Piers/Caissons Inspection - Commercial Pending
Sidewalk Inspection Pending
Water Service Inspection Pending
Misc
Corrective Action Required
01/22/2026
10-16-25 Pex is to shallow. Will need lowered 1-22-26 Dustin A, Water line was buried without an inspection
Erosion Control Inspection Pending
Misc
Corrective Action Required
03/02/2026
-provide gravel entrance and maintain down silt fence around lot.
All Rough Inspection - Commercial Pending 4/3/2026 4/3/2026
Misc
Corrective Action Required
03/18/2026
623 - fireproof roof sheathing must extend 4’ at all separation walls - 623/625, F3 truss calls for lateral bracing , address with engineer , need letter uploaded to permit
Footing Inspection - Commercial Partial 9/3/2025 9/3/2025 09/03/2025
Misc
Corrective Action Required
09/03/2025
-this is a partial footing inspection -Aa/Ak A1-A2 is ok
Footing Inspection - Commercial Partial 9/10/2025 9/10/2025 09/10/2025
Misc
Informational
09/10/2025
Footings okay to pour
Footing Inspection - Commercial Partial 9/16/2025 9/16/2025 09/16/2025
Misc
Informational
09/10/2025
Footings okay to pour -stem walls okay to pour
Sewer Service Inspection Partial 10/1/2025 10/1/2025 10/01/2025
Misc
Informational
10/01/2025
10-1-25 Dustin A, Sewers are ran out to to about 10ft away from stub < asked for a partial so they can backfill to get a bigger machine. Will call back in when Thery dig it back up
Underslab Plumbing Inspection - Commercial Passed 10/2/2025 10/2/2025 10/02/2025
Footing Inspection - Commercial Failed 10/10/2025 10/10/2025 10/10/2025
Misc
Informational
09/16/2025
Footings okay to pour -stem walls okay to pour
Misc
Corrective Action Required
10/10/2025
Inspection denied, see erosion control
Erosion Control Inspection Failed 10/10/2025 10/10/2025 10/10/2025
Misc
Corrective Action Required
10/10/2025
Erosion control not in compliance -dirt and rock in street -silt fence downed around lot -lot access shall be maintained to allow parking and unloading that prevents tracking of mud and materials onto street
Footing Inspection - Commercial Passed 10/14/2025 10/14/2025 10/14/2025
Misc
Resolved
10/14/2025
Footings okay to pour -stem walls okay to pour
Misc
Resolved
10/14/2025
Inspection denied, see erosion control
Rated Assembly Inspection Not Ready 1/6/2026 1/6/2026 01/06/2026
Misc
Corrective Action Required
01/06/2026
Inspection denied due to erosion control not in compliance
Rated Assembly Inspection Passed 1/8/2026 1/8/2026 01/08/2026
Misc
Corrective Action Required
01/06/2026
Inspection denied due to erosion control not in compliance
Sewer Service Inspection Passed 1/20/2026 1/20/2026 01/20/2026
Misc
Informational
10/01/2025
10-1-25 Dustin A, Sewers are ran out to to about 10ft away from stub < asked for a partial so they can backfill to get a bigger machine. Will call back in when They dig it back up 1-20-26 Dustin A. Sewer installed to city spec.
Water Service Inspection Failed 01/22/2026
Misc
Corrective Action Required
01/22/2026
10-16-25 Pex is to shallow. Will need lowered 1-22-26 Dustin A, Water line was buried without an inspection
All Rough Inspection - Commercial Not Ready 3/2/2026 3/2/2026 03/02/2026
Misc
Corrective Action Required
03/02/2026
-Provide complete set of city stamped plans on site for inspection including truss plans -provide gravel entrance and maintain down silt fence around lot.
Erosion Control Inspection Failed 3/2/2026 3/2/2026 03/02/2026
Misc
Corrective Action Required
03/02/2026
-provide gravel entrance and maintain down silt fence around lot.
All Rough Inspection - Commercial Failed 3/5/2026 3/5/2026 03/05/2026
Misc
Resolved
03/05/2026
-Provide complete set of city stamped plans on site for inspection including truss plans -provide gravel entrance and maintain down silt fence around lot.
Misc
Corrective Action Required
03/05/2026
All units- fireproof roof sheathing must extend 4’ from separation wall in all units - address putty pacs throughout are covering entire box as per manufacturer specifications - Dryer vent roof penetration needs boot - better secure wire in stud bays at vanity’s - secure NM in attic space every 4 1/2’ as per NEC 3.34.30 - Double check nail pattern on double trusses throughout 621- Wires in front entry closet must be landed in a box - Missing bracing on trusses B1A 623- secure all NM in attic area every 4 1/2’ - address issue of truss bracing on E1 on separation wall 625- primary bedroom, NM can’t be secured to separation wall - penetration in top plate in primary bedroom - Address cut line set above closet in front hall - Penetration in top plate in front bedroom closet - Land wire for front porch light in box - Double layer of Sheetrock needed behind tub - A1 truss missing bracing, F3 truss calls for lateral bracing , address with engineer 627 - Provide 1” air gap in separation wall as per plan - Penetration at top plate at kitchen/laundry wall - Penetration at ufer ground in top plate - Seal penetrations at top plate in garage at electrical service -
All Rough Inspection - Commercial Not Ready 3/13/2026 3/13/2026 03/13/2026
Misc
Corrective Action Required
03/05/2026
INSPECTION DENIED -NO CITY STAMPED PLANS ON SITE -MULTIPLE ITEMS NOT ADDRESSES All units- fireproof roof sheathing must extend 4’ from separation wall in all units - address putty pacs throughout are covering entire box as per manufacturer specifications - Dryer vent roof penetration needs boot - better secure wire in stud bays at vanity’s - secure NM in attic space every 4 1/2’ as per NEC 3.34.30 - Double check nail pattern on double trusses throughout 621- Wires in front entry closet must be landed in a box - Missing bracing on trusses B1A 623- secure all NM in attic area every 4 1/2’ - address issue of truss bracing on E1 on separation wall 625- primary bedroom, NM can’t be secured to separation wall - penetration in top plate in primary bedroom - Address cut line set above closet in front hall - Penetration in top plate in front bedroom closet - Land wire for front porch light in box - Double layer of Sheetrock needed behind tub - A1 truss missing bracing, F3 truss calls for lateral bracing , address with engineer 627 - Provide 1” air gap in separation wall as per plan - Penetration at top plate at kitchen/laundry wall - Penetration at ufer ground in top plate - Seal penetrations at top plate in garage at electrical service -
All Rough Inspection - Commercial Failed 3/18/2026 3/18/2026 03/18/2026
Misc
Corrective Action Required
03/13/2026
623 - fireproof roof sheathing must extend 4’ at all separation walls - 623/625, F3 truss calls for lateral bracing , address with engineer , need letter uploaded to permit
Electrical Service Inspection Passed 3/23/2026 3/23/2026 03/23/2026
Documents & Images
Date Uploaded File Type Document Name
06/30/2025 Receipt Receipt for transaction:2025-005053
06/30/2025 Letter DS Building Permit
03/31/2025 Approved Plans Approved plans V1
03/06/2025 Approved Plans Approved plans V2
09/03/2025 Letter INSPECTION SUMMARY
09/10/2025 Letter INSPECTION SUMMARY
09/16/2025 Letter INSPECTION SUMMARY
10/01/2025 Letter INSPECTION SUMMARY
10/02/2025 Letter INSPECTION SUMMARY
10/10/2025 Letter INSPECTION SUMMARY
10/10/2025 Letter INSPECTION SUMMARY
10/14/2025 Letter INSPECTION SUMMARY
11/05/2025 Approved Plans Approved G111
11/12/2025 Letter 25-1111_Reunion Building A Revisions Narrative
11/12/2025 Approved Plans Approved S101 A & A-1
11/12/2025 Approved Plans Approved Truss Components A
11/14/2025 Approved Plans Blackwell Code Modification Request2
11/17/2025 Approved Plans Truss repair doc
12/05/2025 Approved Plans Approved Truss Layout A
12/08/2025 Approved Plans Approved E200 revision
01/06/2026 Letter INSPECTION SUMMARY
01/08/2026 Letter INSPECTION SUMMARY
01/20/2026 Letter INSPECTION SUMMARY
01/22/2026 Letter INSPECTION SUMMARY
02/09/2026 Approved Plans REUNION GRADING PLA
03/02/2026 Letter INSPECTION SUMMARY
03/02/2026 Letter INSPECTION SUMMARY
03/05/2026 Letter INSPECTION SUMMARY
03/18/2026 Letter INSPECTION SUMMARY
03/23/2026 Letter INSPECTION SUMMARY
03/23/2026 Letter INSPECTION SUMMARY
04/02/2026 Approved Plans Approved - Truss bracing letter - Stand Review
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home