Summary
PRCOM20203845
Building Permit - Commercial
Certificate of Occupancy
SCHOOL DISTRICT 7 REORGANIZED
NEW COMMERCIAL
NORTH ATHLETIC COMPLEX SERVING NEW MIDDLE SCHOOL Mike Weisenborn 11/20/2020 11:20 AM - FULL PERMIT RELEASED Mike Weisenborn 11/11/2020 9:34 AM - ONLY FOUNDATION RELEASED AT THIS TIME.
10/20/2020
11/11/2020
10/30/2023
Locations
Contacts
MCCOWN GORDON CONSTRUCTION LLC, Address:850 MAIN ST, Phone:(816) 960-1111  
  
  
  
DLR GROUP, Address:7290 W 133RD ST, Phone:(913) 897-7811  
CFS ENGINEERS, Address:1421 EAST 104TH STREET STE 100, Phone:(816) 333-4477  
  
SCHOOL DISTRICT 7 REORGANIZED, Address:301 NE TUDOR RD  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 11/20/2020
Mike Weisenborn
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Commercial $0.00 $0.00 Paid 11/09/2020
$50.00
7232302-Commercial License Tax Fee $4,312.50 $4,312.50 Paid 10/20/2020
$4,312.50
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Commercial Partial 12/17/2020 (8:00) 12/17/2020 12/17/2020
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
12/17/2020
AREA “S” (NORTH ATHLETIC COMPLEX) -UFER AT SOUTHWEST CORNER OF BUILDING -FOOTINGS COMPLETE AT: SOUTHWEST SCREEN WALL, NORTH, EAST, AND SOUTH WALLS
Footing Inspection - Commercial Partial 12/21/2020 (11:30) 12/21/2020 12/21/2020
THE FOLLOWING AREAS ARE APPROVED
Informational
12/21/2020
AREA “S” (NORTH ATHLETIC COMPLEX) -UFER AT SOUTHWEST CORNER OF BUILDING -FOOTINGS FOR BUILDING AND SCREEN WALL COMPLETE
Underslab Plumbing Inspection - Commercial Partial 1/13/2021 1/13/2021 01/13/2021
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
01/13/2021
FIELD HOUSE -DWV COMPLETE
Footing Inspection - Commercial Partial 1/20/2021 (11:30) 1/20/2021 01/20/2021
THE FOLLOWING AREAS ARE APPROVED
Informational
12/21/2020
AREA “S” (NORTH ATHLETIC COMPLEX) -UFER AT SOUTHWEST CORNER OF BUILDING -FOOTINGS FOR BUILDING AND SCREEN WALL COMPLETE -FOOTING FOR RETAINING WALL NORTH OF COMPLEX- —FROM EAST TO WEST FIRST 1/2 OF FOOTING LENGH
Underslab Electrical Inspection - Commercial Partial 1/14/2021 1/21/2021 01/21/2021
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
01/21/2021
-OK TO BACKFILL UNDERGROUND CONDUIT
Underslab Plumbing Inspection - Commercial Partial 1/21/2021 1/21/2021 01/21/2021
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
01/13/2021
FIELD HOUSE -DWV COMPLETE -COMPLETE WATER SERVICE
Underslab Plumbing Inspection - Commercial Passed 01/25/2021
THE FOLLOWING AREAS ARE APPROVED
Informational
01/25/2021
FIELD HOUSE -Complete-
Underslab Electrical Inspection - Commercial Partial 1/25/2021 1/25/2021 01/25/2021
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
01/21/2021
-FIELDHOUSE COMPLETE
Footing Inspection - Commercial Partial 2/5/2021 (9:45) 2/5/2021 02/05/2021
THE FOLLOWING AREAS ARE APPROVED
Informational
01/20/2021
AREA “S” (NORTH ATHLETIC COMPLEX) -UFER AT SOUTHWEST CORNER OF BUILDING -FOOTINGS FOR BUILDING AND SCREEN WALL COMPLETE -FOOTING FOR RADIUS RETAINING WALL NORTH OF COMPLEX-
Footing Inspection - Commercial Partial 2/25/2021 (10:00) 2/25/2021 02/25/2021
THE FOLLOWING AREAS ARE APPROVED
Informational
02/05/2021
AREA “S” (NORTH ATHLETIC COMPLEX) -UFER AT SOUTHWEST CORNER OF BUILDING -FOOTINGS FOR BUILDING AND SCREEN WALL COMPLETE -FOOTING FOR RADIUS RETAINING WALL NORTH OF COMPLEX- -RADIUS FOUNDATION WALL FROM EAST TO WEST, FIRST 100’
Footing Inspection - Commercial Partial 7/8/2021 (9:00) 7/8/2021 03/09/2021
THE FOLLOWING AREAS ARE APPROVED
Informational
02/25/2021
AREA “S” (NORTH ATHLETIC COMPLEX) -UFER AT SOUTHWEST CORNER OF BUILDING -FOOTINGS FOR BUILDING AND SCREEN WALL COMPLETE -FOOTING FOR RADIUS RETAINING WALL NORTH OF COMPLEX- -RADIUS FOUNDATION WALL COMPLETE
Rough Framing Inspection - Commercial Partial 04/23/2021
THE FOLLOWING AREAS ARE APPROVED
Informational
04/23/2021
-OK TO COVER EXTERIOR SOFFITS/ PARAPET WALL EAST AND SOUTH SIDE OF BUILDING
Rough Framing Inspection - Commercial Partial 04/27/2021
THE FOLLOWING AREAS ARE APPROVED
Informational
04/23/2021
-OK TO COVER EXTERIOR SOFFITS/ PARAPET WALL EAST, NORTH, AND SOUTH SIDE OF BUILDING
In-wall Inspection Partial 4/23/2021 5/10/2021 05/10/2021
Misc
Informational
05/10/2021
Areas approved: Men's room (east side of complex)
In-wall Inspection Partial 5/12/2021 5/12/2021 05/12/2021
Misc
Informational
05/10/2021
Areas approved: Men's room (east side of complex) toilets and sinks
In-wall Inspection Partial 5/13/2021 5/13/2021 05/13/2021
Misc
Informational
05/12/2021
Areas approved: Men's room (east side of complex) toilets and sinks Women’s room toilets and sinks
Footing Inspection - Commercial Partial 5/13/2021 (11:30) 5/13/2021 05/13/2021
THE FOLLOWING AREAS ARE APPROVED
Informational
03/09/2021
AREA “S” (NORTH ATHLETIC COMPLEX) -UFER AT SOUTHWEST CORNER OF BUILDING -FOOTINGS FOR BUILDING AND SCREEN WALL COMPLETE -FOOTING FOR RADIUS RETAINING WALL NORTH OF COMPLEX- -RADIUS FOUNDATION WALL COMPLETE BASEBALL DIAMONDS: -SOUTHEAST HOME AND VISITORS DUGOUTS
In-wall Inspection Passed 05/19/2021
Misc
Informational
05/13/2021
Areas approved: Men's room (east side of complex) toilets and sinks Women’s room toilets and sinks, coaches room
Above Ceiling Inspection Partial 4/27/2021 5/19/2021 05/19/2021
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
05/19/2021
-EXTERIOR SOFFIT LIGHTS NORTH, EAST AND SOUTH COMPLEX
Above Ceiling Inspection Partial 6/1/2021 6/1/2021 06/01/2021
THE FOLLOWING AREAS ARE APPROVED
Informational
06/01/2021
-EXTERIOR SOFFIT LIGHTS NORTH, EAST AND SOUTH COMPLEX
Miscellaneous Correction
Corrective Action Required
06/01/2021
-Complete all MEPs and framing at hard lids before inspection inside of field house
Footing Inspection - Commercial Partial 6/4/2021 (1:00) 6/4/2021 06/04/2021
THE FOLLOWING AREAS ARE APPROVED
Informational
05/13/2021
AREA “S” (NORTH ATHLETIC COMPLEX) -UFER AT SOUTHWEST CORNER OF BUILDING -FOOTINGS FOR BUILDING AND SCREEN WALL COMPLETE -FOOTING FOR RADIUS RETAINING WALL NORTH OF COMPLEX- -RADIUS FOUNDATION WALL COMPLETE BASEBALL DIAMONDS: -SOUTHEAST, NORTHWEST HOME AND VISITORS DUGOUTS
Above Ceiling Inspection Partial 6/7/2021 6/7/2021 06/07/2021
THE FOLLOWING AREAS ARE APPROVED
Informational
06/01/2021
-EXTERIOR SOFFIT LIGHTS NORTH, EAST AND SOUTH OF COMPLEX -HARD LID AT FAMILY RESTROOM AT NORTHEAST SIDE OF COMPLEX
Miscellaneous Correction
Corrective Action Required
06/01/2021
Footing Inspection - Commercial Partial 6/9/2021 (1:30) 6/9/2021 06/09/2021
THE FOLLOWING AREAS ARE APPROVED
Informational
06/04/2021
AREA “S” (NORTH ATHLETIC COMPLEX) -UFER AT SOUTHWEST CORNER OF BUILDING -FOOTINGS FOR BUILDING AND SCREEN WALL COMPLETE -FOOTING FOR RADIUS RETAINING WALL NORTH OF COMPLEX- -RADIUS FOUNDATION WALL COMPLETE BASEBALL DIAMONDS: -NOTHEAST, NORTHWEST, SOUTHEAST HOME AND VISITORS DUGOUTS
Underground Electrical Inspection - Commercial Partial 6/11/2021 6/11/2021 06/11/2021
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
06/11/2021
-Conduit from Southwest corner of building north to 20' short of CT location
Footing Inspection - Commercial Passed 6/16/2021 (1:00) 6/16/2021 06/16/2021
THE FOLLOWING AREAS ARE APPROVED
Informational
06/09/2021
AREA “S” (NORTH ATHLETIC COMPLEX) -UFER AT SOUTHWEST CORNER OF BUILDING -FOOTINGS FOR BUILDING AND SCREEN WALL COMPLETE -FOOTING FOR RADIUS RETAINING WALL NORTH OF COMPLEX- -RADIUS FOUNDATION WALL COMPLETE BASEBALL DIAMONDS: -NOTHEAST, NORTHWEST, SOUTHEAST AND SOUTHWEST HOME AND VISITORS DUGOUTS
Underground Electrical Inspection - Commercial Partial 6/16/2021 6/16/2021 06/16/2021
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
06/11/2021
-Conduit from Southwest corner of building north to 20' short of CT location -Conduit for monument sign at Northeast entrance and Left field Musco light at northeast diamond to west end of NE diamond
Piers/Caissons Inspection - Commercial Partial 6/17/2021 (1:00) 6/17/2021 06/17/2021
Misc
Informational
06/17/2021
AREAS APPROVED: 3 OF 4 PIERS FOR NORTHEAST FIELD BLEACHER CANOPY
Underground Electrical Inspection - Commercial Partial 6/23/2021 6/23/2021 06/23/2021
THE FOLLOWING AREAS ARE APPROVED
Informational
06/23/2021
-Conduit from Southwest corner of building north to CT and Transformer location -Conduit for monument sign at Northeast entrance and Left field Musco light at northeast diamond to west end of NE diamond -Conduit for left field Musco light at NW diamond
Underslab Electrical Inspection - Commercial Partial 06/23/2021
THE FOLLOWING AREAS ARE APPROVED
Informational
06/23/2021
-FIELDHOUSE COMPLETE -CONDUIT FOR DUGOUTS AND STORAGE ROOMS AT NORHTEAST FIELD
Piers/Caissons Inspection - Commercial Partial 6/23/2021 06/23/2021
Misc
Informational
06/17/2021
AREAS APPROVED: 3 OF 4 PIERS FOR NORTHEAST FIELD BLEACHER CANOPY 3 OF 4 PIERS FOR NORTHWEST FIELD BLEACHER CANOPY
Underground Electrical Inspection - Commercial Partial 7/7/2021 7/7/2021 07/07/2021
THE FOLLOWING AREAS ARE APPROVED
Informational
06/23/2021
-Conduit from Southwest corner of building north to CT and Transformer location -Conduit for monument sign at Northeast entrance and Left field Musco light at northeast diamond to west end of NE diamond -Conduit for left field Musco light at NW diamond -Conduit from NW dugout electrical room to scoreboards
Footing Inspection - Commercial Partial 7/8/2021 (9:00) 7/8/2021 07/08/2021
THE FOLLOWING AREAS ARE APPROVED
Corrective Action Required
07/08/2021
-(2) pier pads for canopy backstops at ball fields
Underground Electrical Inspection - Commercial Partial 7/9/2021 7/9/2021 07/09/2021
THE FOLLOWING AREAS ARE APPROVED
Informational
07/07/2021
-Conduit from Southwest corner of building north to CT and Transformer location -Conduit for monument sign at Northeast entrance and Left field Musco light at northeast diamond to west end of NE diamond -Conduit for left field Musco light at NW diamond -Conduit from NW dugout electrical room to scoreboards -Conduit between north fields to NW dugout and field house for musco lights, power and communications
Above Ceiling Inspection Passed 8/6/2021 8/6/2021 08/06/2021
THE FOLLOWING AREAS ARE APPROVED
Informational
06/07/2021
-EXTERIOR SOFFIT LIGHTS NORTH, EAST AND SOUTH OF COMPLEX -HARD LID AT FAMILY RESTROOM AT NORTHEAST SIDE OF COMPLEX -DROP CEILINGS IN COACH'S ROOM AND CONCESSION
Miscellaneous Correction
Corrective Action Required
06/07/2021
Electrical Service Inspection Passed 8/12/2021 8/12/2021 08/12/2021
Misc
Informational
08/12/2021
Service for fieldhouse
Miscellaneous Inspection Partial 9/20/2021 9/20/2021 09/20/2021
Misc
Informational
09/20/2021
-S100 OK FOR USE TO STORE EQUIPMENT
Underground Electrical Inspection - Commercial Partial 9/29/2021 9/29/2021 09/29/2021
THE FOLLOWING AREAS ARE APPROVED
Informational
07/09/2021
-Conduit from Southwest corner of building north to CT and Transformer location -Conduit for monument sign at Northeast entrance and Left field Musco light at northeast diamond to west end of NE diamond -Conduit for left field Musco light at NW diamond -Conduit from NW dugout electrical room to scoreboards -Conduit between north fields to NW dugout and field house for musco lights, power and communications -Conduit for (4) batting cages between 2 north fields
Miscellaneous Inspection Partial 9/21/2021 09/29/2021
Misc
Informational
09/20/2021
-S100 OK FOR USE TO STORE EQUIPMENT
Misc
Informational
09/29/2021
Meet on site with Mike Weissenbach of the Fire Department to determine if the NW ball field could be utilized for the senior night game on October 4th. All life safety, access and parking requirements are being meet for this location. Protective fencing is being installed to separate the construction area off. Portable facilities will be provided. Staff will be on site to provide additional safety. The NW field is being released to be used for its intended purposes in the afternoon and early evening on Monday, October 4th, 2020. Mike Weisenborn 09/29/2021 3:48 PM
Underslab Electrical Inspection - Commercial Partial 11/2/2021 11/2/2021 11/02/2021
THE FOLLOWING AREAS ARE APPROVED
Informational
06/23/2021
-FIELDHOUSE COMPLETE -CONDUIT FOR DUGOUTS AND STORAGE ROOMS
Miscellaneous Inspection Partial 2/1/2022 2/1/2022 02/01/2022
Misc
Informational
09/29/2021
-S100 OK FOR USE TO STORE EQUIPMENT
Misc
Informational
09/29/2021
Meet on site with Mike Weissenbach of the Fire Department to determine if the NW ball field could be utilized for the senior night game on October 4th. All life safety, access and parking requirements are being meet for this location. Protective fencing is being installed to separate the construction area off. Portable facilities will be provided. Staff will be on site to provide additional safety. The NW field is being released to be used for its intended purposes in the afternoon and early evening on Monday, October 4th, 2020. Mike Weisenborn 09/29/2021 3:48 PM
Misc
Corrective Action Required
02/01/2022
2/1/22 INSPECTION OF REMAINING FIELDS AND NORTH ATHLETIC COMPLEX FOR TCO -BLOCK OFF ENTRANCE TO RESTROOM FACILITIES -100A-COMPLETE 3 COMPARTMENT SINK -105-PROVIDE COVER PLATE AT SWITCH -LABEL MUSCO PANEL -PROVIDE SIGNAGE AT ELECTRICAL ROOM DOOR -PROVIDE PANEL SCHEDULES AT ALL FIELD PANELS -SW FIELD: NO POWER, H2.5S ON END RAFTER BOTH DOUGOUTS -SE FIELD: NO POWER, LOWER LAST 2 H2.5S TO BE ABLE TO INSTALL PROPER AMOUNT OF NAILS -NE FIELD: MISSING COVER PLATE IN ELECTRICAL, DOUGOUTS OK
Occupancy Inspection - Codes Commercial Failed 2/11/2022 2/11/2022 02/11/2022
Miscellaneous Correction
Corrective Action Required
02/11/2022
*No TCO on this building until domestic water and sewer are installed and all other departments have approved occupancy *Codes approval for use only for the North Athletic Complex and fields excluding restrooms, showers, and concession area -Install permanent signage at electrical room -Complete 3 compartment sink at concession -Install fire extiguisher at concession -Complete water and sewer
Underslab Electrical Inspection - Commercial Passed 2/22/2022 2/22/2022 02/22/2022
THE FOLLOWING AREAS ARE APPROVED
Resolved
02/22/2022
-FIELDHOUSE COMPLETE -CONDUIT FOR DUGOUTS AND STORAGE ROOMS
Occupancy Inspection - Codes Commercial Failed 02/23/2022
Miscellaneous Correction
Corrective Action Required
02/11/2022
*No TCO on this building until domestic water and sewer are installed and all other departments have approved occupancy *Codes approval for use only for the North Athletic Complex and fields excluding restrooms, showers, and concession area -Install permanent signage at electrical room -Install fire extiguisher at concession -Complete water and sewer
Miscellaneous Inspection Failed 2/23/2022 2/28/2022 02/28/2022
Misc
Informational
02/01/2022
-S100 OK FOR USE TO STORE EQUIPMENT
Misc
Informational
02/01/2022
Meet on site with Mike Weissenbach of the Fire Department to determine if the NW ball field could be utilized for the senior night game on October 4th. All life safety, access and parking requirements are being meet for this location. Protective fencing is being installed to separate the construction area off. Portable facilities will be provided. Staff will be on site to provide additional safety. The NW field is being released to be used for its intended purposes in the afternoon and early evening on Monday, October 4th, 2020. Mike Weisenborn 09/29/2021 3:48 PM
Misc
Corrective Action Required
02/01/2022
2/28/22 INSPECTION OF REMAINING FIELDS AND NORTH ATHLETIC COMPLEX FOR TCO -PROVIDE PERMANENT SIGNAGE AT ELECTRICAL ROOM DOOR -PROVIDE ANTI SIPHON DEVICE AT HOSE BIB -COMPLETE WATER AND SANITARY
Miscellaneous Inspection Failed 03/07/2022
Misc
Informational
02/28/2022
-S100 OK FOR USE TO STORE EQUIPMENT
Misc
Partial Correction
03/07/2022
Mike Weisenborn 09/29/2021 3:48 PM Meet on site with Mike Weissenbach of the Fire Department to determine if the NW ball field could be utilized for the senior night game on October 4th. All life safety, access and parking requirements are being meet for this location. Protective fencing is being installed to separate the construction area off. Portable facilities will be provided. Staff will be on site to provide additional safety. The NW field is being released to be used for its intended purposes in the afternoon and early evening on Monday, October 4th, 2020. Mike Weisenborn 03/07/2022 10:20 AM City staff has completed additional inspections on the North Athletic Complex and the fields have been released to be used for their intended purposes. In addition to Storage S100, the following areas have been released to be used for their intended purposes. S102 Visitor Changing Room S103 Coaches Office S105 Locker S108 Home Changing Room S111 Concessions has been released for the sale of items that do not require approval and a food handling license from the Jackson County Health Department. All other areas (areas with plumbing fixtures) have not been released until water and sanitary is provided to the facility. Temporary facilities shall be provided at anytime the facility is in use.
Misc
Corrective Action Required
02/28/2022
2/28/22 INSPECTION OF REMAINING FIELDS AND NORTH ATHLETIC COMPLEX FOR TCO -PROVIDE PERMANENT SIGNAGE AT ELECTRICAL ROOM DOOR -PROVIDE ANTI SIPHON DEVICE AT HOSE BIB -COMPLETE WATER AND SANITARY
Footing Inspection - Commercial Passed 8/11/2021 (11:30) 09/01/2022
THE FOLLOWING AREAS ARE APPROVED
Resolved
09/01/2022
-(2) pier pads for canopy backstops at ball fields
Rough Framing Inspection - Commercial Passed 09/01/2022
THE FOLLOWING AREAS ARE APPROVED
Resolved
09/01/2022
-OK TO COVER EXTERIOR SOFFITS/ PARAPET WALL EAST, NORTH, AND SOUTH SIDE OF BUILDING
Underground Electrical Inspection - Commercial Passed 09/01/2022
THE FOLLOWING AREAS ARE APPROVED
Resolved
09/01/2022
-Conduit from Southwest corner of building north to CT and Transformer location -Conduit for monument sign at Northeast entrance and Left field Musco light at northeast diamond to west end of NE diamond -Conduit for left field Musco light at NW diamond -Conduit from NW dugout electrical room to scoreboards -Conduit between north fields to NW dugout and field house for musco lights, power and communications -Conduit for (4) batting cages between 2 north fields
Piers/Caissons Inspection - Commercial Passed 09/01/2022
Misc
Resolved
09/01/2022
AREAS APPROVED: 3 OF 4 PIERS FOR NORTHEAST FIELD BLEACHER CANOPY 3 OF 4 PIERS FOR NORTHWEST FIELD BLEACHER CANOPY
Gas Piping Inspection - Commercial Passed 09/01/2022
Occupancy Inspection - Codes Commercial Failed 09/01/2022
Miscellaneous Correction
Corrective Action Required
02/23/2022
Obtain approval from Health Department Complete outstanding item for Fire Department *Codes complete
Occupancy Inspection - Codes Commercial Full C of O 10/30/2023
Miscellaneous Correction
Resolved
10/30/2023
Obtain approval from Health Department Complete outstanding item for Fire Department *Codes complete
Documents & Images
Date Uploaded File Type Document Name
10/20/2020 Letter License Tax Bill
10/20/2020 Approved Plans Approved Foundation Plans
11/11/2020 Letter DS Building Permit
11/20/2020 Letter DS Building Permit
12/17/2020 Letter INSPECTION SUMMARY
12/17/2020 Letter Codes Plan Review Conditions
12/21/2020 Letter INSPECTION SUMMARY
01/13/2021 Letter INSPECTION SUMMARY
01/20/2021 Letter INSPECTION SUMMARY
01/21/2021 Letter INSPECTION SUMMARY
01/21/2021 Letter INSPECTION SUMMARY
01/25/2021 Letter INSPECTION SUMMARY
01/25/2021 Letter INSPECTION SUMMARY
01/26/2021 Approved Plans Approved LSMS Field Lighting
01/26/2021 Approved Plans Approved LSMS Light Pole Base Design
02/05/2021 Letter INSPECTION SUMMARY
02/25/2021 Letter INSPECTION SUMMARY
03/09/2021 Letter INSPECTION SUMMARY
04/23/2021 Letter INSPECTION SUMMARY
04/27/2021 Letter INSPECTION SUMMARY
05/10/2021 Letter INSPECTION SUMMARY
05/12/2021 Letter INSPECTION SUMMARY
05/13/2021 Letter INSPECTION SUMMARY
05/13/2021 Letter INSPECTION SUMMARY
05/19/2021 Letter INSPECTION SUMMARY
05/19/2021 Letter INSPECTION SUMMARY
06/01/2021 Letter INSPECTION SUMMARY
06/04/2021 Letter INSPECTION SUMMARY
06/07/2021 Letter INSPECTION SUMMARY
06/09/2021 Letter INSPECTION SUMMARY
06/11/2021 Letter INSPECTION SUMMARY
06/16/2021 Letter INSPECTION SUMMARY
06/16/2021 Letter INSPECTION SUMMARY
06/17/2021 Letter INSPECTION SUMMARY
06/23/2021 Letter INSPECTION SUMMARY
06/23/2021 Letter INSPECTION SUMMARY
06/23/2021 Letter INSPECTION SUMMARY
07/07/2021 Letter INSPECTION SUMMARY
07/08/2021 Letter INSPECTION SUMMARY
07/09/2021 Letter INSPECTION SUMMARY
07/09/2021 Letter INSPECTION SUMMARY
07/09/2021 Letter INSPECTION SUMMARY
08/06/2021 Letter INSPECTION SUMMARY
08/06/2021 Letter INSPECTION SUMMARY
08/12/2021 Letter INSPECTION SUMMARY
09/20/2021 Letter INSPECTION SUMMARY
09/29/2021 Letter INSPECTION SUMMARY
09/29/2021 Letter INSPECTION SUMMARY
11/02/2021 Letter INSPECTION SUMMARY
02/01/2022 Letter INSPECTION SUMMARY
02/11/2022 Letter INSPECTION SUMMARY
02/22/2022 Letter INSPECTION SUMMARY
02/23/2022 Letter INSPECTION SUMMARY
02/28/2022 Letter INSPECTION SUMMARY
03/07/2022 Letter INSPECTION SUMMARY
09/01/2022 Letter INSPECTION SUMMARY
09/01/2022 Letter INSPECTION SUMMARY
09/01/2022 Letter INSPECTION SUMMARY
09/01/2022 Letter INSPECTION SUMMARY
09/01/2022 Letter INSPECTION SUMMARY
09/01/2022 Letter INSPECTION SUMMARY
10/30/2023 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home