Summary
PRCOM20202923
Building Permit - Commercial
Certificate of Occupancy
C82 MESA LLC
CHANGE OF TENANT
TENANT FINISH FOR COFFEE SHOP WITH DRIVE-THRU
09/10/2020
11/09/2020
03/13/2021
01/14/2021
Locations
Contacts
Capitol Construction Services, Inc., Address:11051 Village Square Lane, Phone:(317) 574-5488  
DONALDSON MECHANICAL INC, Address:934 SE 7TH TER, Unit B, Phone:(816) 246-9500  
DMR SERVICES INC, Address:27215 S LEWIS RD, Phone:(816) 899-2159  
J-HAWK PLUMBING INC, Address:3615 W MAPLE ST, Phone:(316) 942-7279  
C82 MESA LLC, Address:7015 SNIDER PLZ STE 203  
csears@capitolconstruct.com, Address:csears@capitolconstruct.com  
NORR Architects, Address:325 Norht Lasalle Street - Suite 500, Phone:(312) 424-2400  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 09/30/2020 11/09/2020
Joe Frogge
LC - General Contractor
Resolved
11/06/2020

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the name of the licensed general contractor. 9/24/20 - acknowledged in letter.
LC - MEP Subs
Resolved
11/09/2020

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors. 9/24/20 - acknowledged in letter.
Building Plan Review Approved with Conditions 09/30/2020 09/24/2020
Joe Frogge
Misc
Corrective Action Required
09/23/2020

This tenant finish permit is associated with an incomplete shell permit. Action required: Comment is for informational purposes. Occupancy will not be granted for the tenant prior to completion of shell permit. 9/24/20 - acknowledged in letter.
Misc
Resolved
11/06/2020

A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit. Action required: Comment is for informational purposes. 9/24/20 - acknowledged in letter.
Health Dept Inspection
Corrective Action Required
09/23/2020

For the Health Department inspection contact Deb Sees with the Jackson County Public Works Department, Environmental Health Division at (816) 847-7070. Health Department approval is required prior to receiving any type of Occupancy from the City of Lee's Summit. Action required: Comment is for informational purposes. 9/24/20 - acknowledged in letter.
IBC 602.1 Type of Construction - general
Resolved
09/24/2020

2018 IBC 602.1 General. Buildings and structures erected or to be erected, altered or extended in height or area shall be classified in one of the five construction types defined in Sections 602.2 through 602.5. the building elements shall have a fire-resistance rating not less than that specified in Table 601 and exterior walls shall have a fire resistance rating not less than that specified in Table 602. Where required to have a fire-resistance rating by Table 601, building elements shall comply with the applicable provisions of Section 703.2. The protection for openings, ducts and air transfer openings in building elements shall not be required unless required by other provisions of this code. Action required: Revise code analysis to show correct building construction type which is 5B.
Fire Plan Review Approved with Conditions 09/30/2020 09/23/2020
Michael Weissenbach
Posting of occupant load
Corrective Action Required
09/23/2020

2018 IFC 1004.3- Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. (Verified At Inspection) Post occupant load signage at 74 interior and 18 for the outdoor space.
Address numbers required
Corrective Action Required
09/23/2020

2018 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). (Verified At Inspection) Address all exterior doors.
Duct smoke detectors
Corrective Action Required
09/23/2020

2018 IFC 907.3.1 Duct smoke detectors. Smoke detectors installed in ducts shall be listed for the air velocity, temperature and humidity present in the duct. Duct smoke detectors shall be connected to the building's fire alarm control unit when a fire alarm system is rquired by Section 907.2. Activation of a duct smoke detector shall initiate a visible and audible supervisory signal at a constantly attended location and shall perform the intended fire safety function in accordance with theis code and the International Mechanical Code. Duct smoke detectors shall not be used as a substitute for required open area detection. (Verified At Inspection) Label remote test switches that correlate with the RTU'S.
Illumination required
Resolved
09/23/2020

2018 IFC 1008.1 Illumination required. The means of egress, shall be illuminated at all times the building space served by the means of egress is occupied. (Verified At Inspection) Provide exterior emergency lighting at the exit doors.
Health Department Review Approved 09/15/2020
Joe Frogge
Building Plan Review Rejected 09/22/2020 09/10/2020
Joe Frogge
Misc
Corrective Action Required
09/10/2020

This tenant finish permit is associated with an incomplete shell permit. Action required: Comment is for informational purposes. Occupancy will not be granted for the tenant prior to completion of shell permit.
Misc
Corrective Action Required
09/10/2020

A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit. Action required: Comment is for informational purposes.
Health Dept Review
Resolved
09/15/2020

For the Health Department review contact Deb Sees with the Jackson County Public Works Department, Environmental Services Division, at (816) 847-7070. Health Department approval is required prior to receiving any type of building permit from the City of Lee's Summit. Action required: Comment is for informational purposes.
Health Dept Inspection
Corrective Action Required
09/10/2020

For the Health Department inspection contact Deb Sees with the Jackson County Public Works Department, Environmental Health Division at (816) 847-7070. Health Department approval is required prior to receiving any type of Occupancy from the City of Lee's Summit. Action required: Comment is for informational purposes.
IBC 602.1 Type of Construction - general
Corrective Action Required
09/10/2020

2018 IBC 602.1 General. Buildings and structures erected or to be erected, altered or extended in height or area shall be classified in one of the five construction types defined in Sections 602.2 through 602.5. the building elements shall have a fire-resistance rating not less than that specified in Table 601 and exterior walls shall have a fire resistance rating not less than that specified in Table 602. Where required to have a fire-resistance rating by Table 601, building elements shall comply with the applicable provisions of Section 703.2. The protection for openings, ducts and air transfer openings in building elements shall not be required unless required by other provisions of this code. Action required: Revise code analysis to show correct building construction type which is 5B.
Fire Plan Review Approved with Conditions 09/22/2020 09/10/2020
Michael Weissenbach
Posting of occupant load
Corrective Action Required
09/10/2020

2018 IFC 1004.3- Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. (Verified At Inspection) Post occupant load signage at 74 interior and 18 for the outdoor space.
Address numbers required
Corrective Action Required
09/10/2020

2018 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). (Verified At Inspection) Address all exterior doors.
Duct smoke detectors
Corrective Action Required
09/10/2020

2018 IFC 907.3.1 Duct smoke detectors. Smoke detectors installed in ducts shall be listed for the air velocity, temperature and humidity present in the duct. Duct smoke detectors shall be connected to the building's fire alarm control unit when a fire alarm system is rquired by Section 907.2. Activation of a duct smoke detector shall initiate a visible and audible supervisory signal at a constantly attended location and shall perform the intended fire safety function in accordance with theis code and the International Mechanical Code. Duct smoke detectors shall not be used as a substitute for required open area detection. (Verified At Inspection) Label remote test switches that correlate with the RTU'S.
Illumination required
Corrective Action Required
09/10/2020

2018 IFC 1008.1 Illumination required. The means of egress, shall be illuminated at all times the building space served by the means of egress is occupied. (Action Required) Provide exterior emergency lighting at the exit doors.
Licensed Contractors Rejected 09/22/2020 09/10/2020
Joe Frogge
LC - General Contractor
Corrective Action Required
09/10/2020

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the name of the licensed general contractor.
LC - MEP Subs
Corrective Action Required
09/10/2020

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Change of Tenant $1,000.00 $1,000.00 Paid 11/09/2020
$0.00
8331507-Sewer Connection Fee $390.00 $390.00 Paid 11/09/2020
7232302-Commercial License Tax Fee $36,067.50 $36,067.50 Paid 11/09/2020
$22,117.50
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Commercial Partial 11/11/2020 11/11/2020 11/11/2020
Misc
Informational
11/11/2020
- INSPECTED UNDERSLAB PLUMBING ON E SIDE TENANT (COFFEE SHOP) SIDE OF BUILDING, PRESSURE OVER 5 PSI
Underslab Electrical Inspection - Commercial Partial 11/13/2020 11/13/2020 11/13/2020
Misc
Informational
11/13/2020
- INSPECTED UNDERSLAB CONDUIT FOR ELECTRICAL ON E SIDE (COFFEE SHOP) TENANT SIDE, OK TO COVER PORTION INSPECTED
In-wall Inspection Failed 11/24/2020 11/24/2020 11/24/2020
Misc
Corrective Action Required
11/24/2020
- PROTECTION PLATES AT DWV
In-wall Inspection Partial 11/25/2020 11/25/2020 11/25/2020
Above Ceiling Inspection Failed 12/22/2020 12/22/2020 12/22/2020
Misc
Corrective Action Required
12/22/2020
-SECURE MC CABLE OFF CEILING GRID (2) LOCATIONS DINING -BACK KITCHEN AREA S, INSTALL PANEL COVER ON E WALL, INSTALL COVERS ON (2) JUNCTION BOXES (1) CENTER, (1) S WALL -SECURE MC CABLE AT WALL PENETRATION S WALL OK TO INSTALL PANELS AT OTHER LOCATIONS, LEAVE CORRECTION AREAS OPEN FOR INSPECTION
Occupancy Inspection - Fire Failed 1/13/2021 1/13/2021 01/13/2021
In-wall Inspection Passed 01/13/2021
Above Ceiling Inspection Passed 1/13/2021 1/13/2021 01/13/2021
Misc
Resolved
01/13/2021
-SECURE MC CABLE OFF CEILING GRID (2) LOCATIONS DINING -BACK KITCHEN AREA S, INSTALL PANEL COVER ON E WALL, INSTALL COVERS ON (2) JUNCTION BOXES (1) CENTER, (1) S WALL -SECURE MC CABLE AT WALL PENETRATION S WALL OK TO INSTALL PANELS AT OTHER LOCATIONS, LEAVE CORRECTION AREAS OPEN FOR INSPECTION
Occupancy Inspection - Codes Commercial Failed 1/13/2021 1/13/2021 01/13/2021
Misc
Corrective Action Required
01/13/2021
- PENDING HEALTH DEPARTMENT APPROVAL - PENDING FIRE APPROVAL OF CORRECTIONS -PENDING RESOLUTION OF RATED DEMISING WALL BETWEEN TENANT ISSUE FOR OCCUPANCY OF SHELL PERMIT
Occupancy Inspection - Fire Passed 1/14/2021 01/14/2021
Occupancy Inspection - Codes Commercial Full C of O 01/14/2021
Misc
Resolved
01/14/2021
- PENDING HEALTH DEPARTMENT APPROVAL - PENDING FIRE APPROVAL OF CORRECTIONS -PENDING RESOLUTION OF RATED DEMISING WALL BETWEEN TENANT ISSUE FOR OCCUPANCY OF SHELL PERMIT
Occupancy Inspection - Health Passed 02/10/2021
Documents & Images
Date Uploaded File Type Document Name
09/10/2020 Plans 88084-001_63039 Rt_291 & 150_CD_Permitting Set_22x34
09/10/2020 Application Form Application
09/10/2020 Letter Letter with seals
09/10/2020 Letter Fire Building Plan Review
09/14/2020 Letter DS P/R Corrections Document
09/15/2020 Email New Food Establishment Plan Review - Approved FTG 0001827
09/23/2020 Letter 88084-001_MO Rt_ 291 & 150_Revision 1_Response Letter
09/23/2020 Plans 88084-001_MO Rt_291 & 150_CD_Revision 1_22x34
09/23/2020 Email Starbucks #63039 - RTE 291 & 150 - HEALTH APPROVAL EMAIL
09/23/2020 Letter Fire Building Plan Review
09/24/2020 Approved Plans Approved - Starbucks 63039
11/06/2020 Application Form License Tax Application
11/06/2020 Application Form Permit Application
11/06/2020 Letter License Tax Bill
11/09/2020 Receipt Receipt for transaction:2020-007467
11/09/2020 Letter Codes Plan Review Conditions
11/09/2020 Letter DS Building Permit
11/11/2020 Letter INSPECTION SUMMARY
11/13/2020 Letter INSPECTION SUMMARY
11/24/2020 Letter INSPECTION SUMMARY
11/25/2020 Letter INSPECTION SUMMARY
12/22/2020 Letter INSPECTION SUMMARY
01/13/2021 Letter INSPECTION SUMMARY
01/13/2021 Letter Fire Loss Reduction Form
01/13/2021 Letter INSPECTION SUMMARY
01/13/2021 Letter INSPECTION SUMMARY
01/13/2021 Letter INSPECTION SUMMARY
01/14/2021 Letter Fire Loss Reduction Form
01/14/2021 Letter INSPECTION SUMMARY
01/14/2021 Letter Health Deparment Inspection
01/14/2021 Letter Field Certificate of Occupancy
01/14/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home