Permit Application Status

PRCOM20201133


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20201133
Building Permit - Commercial
Certificate of Occupancy
JAMS LEES BUSTER LLC
CHANGE OF TENANT
TENANT FINISH FOR MARIJUANA DISPENSARY
05/04/2020
05/14/2020
11/02/2020
09/11/2020
Locations
Contacts
BENNETT HOME IMPROVEMENT & BUILDING INC, Address:708 NW R D MIZE RD STE J , Phone:(816) 229-4711  
COMPLETE COMFORT HTG & CLG LLC, Address:714 NW 201 RD, Phone:(816) 694-3912  
PORTER ELECTRICAL, Address:114 VETERANS PKWY, Phone:(816) 540-3271  
RITEWAY PLUMBING LLC, Address:2101 SW OSAGE DR, Phone:(816) 813-9849  
The Hive Design Collaborative, Address:1617 Walnut St, Phone:(816) 581-6363  
JAMS LEES BUSTER LLC, Address:605 W 47TH ST STE 200  
Reviews
Review Type Outcome Est. Completion Date Completed
Building Plan Review Approved 05/19/2020 05/14/2020
Joe Frogge
Miscellaneous Correction
Resolved
05/14/2020

A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit. Action required: Comment is for informational purposes. 5/13/20 - acknowledged in letter
Suite address
Resolved
05/13/2020

This structure has been assigned one address. All suites/apartments shall be assigned an address by the owner which can be numeric, alphabetic or a combination of both. If the building has multiple stories the suite/apartment number shall start with a number representing the floor on which the unit is located. Action required: Verify address and update records. Drawing G02 seems to indicate that this suite is the southernmost so would be 1041 NE Sam Walton Ln, Unit:A but the drawings look like this may be suite B. Also, the door to the north of Game Stop has a Fresh Green sign.
IBC 602.1 Type of Construction - general
Resolved
05/13/2020

2018 IBC 602.1 General. Buildings and structures erected or to be erected, altered or extended in height or area shall be classified in one of the five construction types defined in Sections 602.2 through 602.5. the building elements shall have a fire-resistance rating not less than that specified in Table 601 and exterior walls shall have a fire resistance rating not less than that specified in Table 602. Where required to have a fire-resistance rating by Table 601, building elements shall comply with the applicable provisions of Section 703.2. The protection for openings, ducts and air transfer openings in building elements shall not be required unless required by other provisions of this code. Action required: Update drawings to show correct building type which is Type 5B. (fyi- this is shown in multiple locations)
IBC 1004.1 Design occupant load
Resolved
05/13/2020

2018 IBC 1004.1 Design occupant load. In determining means of egress requirements, the number of occupants for whom means of egress facilities shall be provided shall be determined in accordance with this section. Action required: Update drawings to show occupant load of 1 person per 7 square feet in waiting area. 5/13/20 - permitted to use 1:15 after seeing furniture layout
IBC 1004.2.1 Intervening spaces or accessory areas
Resolved
05/13/2020

2018 IBC 1004.2.1 Intervening spaces or accessory areas. Where occupants egress from one or more rooms, areas or spaces though others, the design occupant load shall be the combined occupant load of interconnected accessory or intervening spaces. Design of egress path capacity shall be based on the cumulative portion of occupant loads of all rooms, areas or spaces to that point along the path of egress travel. Action required: Modify design to provide 2 exits out of Waiting Area. Occupant load is cumulative, i.e. must include Retail area also.
IBC 2902.2 Separate facilities - fixture
Resolved
05/13/2020

2018 IBC 2902.2 Separate Facilities. Where plumbing fixtures are required, separate facilities shall be provided for each sex. (see code for exceptions) Action required: Comment is for informational purposes. Previous comments may increase occupant load to greater than 100 which would require patron access to second restroom.
IBC 1004.9 Posting of occupant load
Resolved
05/13/2020

2018 IBC 1004.9 Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space for the intended configurations. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. Action required: Maximum occupancy posting required in Waiting area.
IPC 403.1 Minimum number of fixtures
Resolved
05/13/2020

2018 IPC 403.1 Minimum number of fixtures. Plumbing fixtures shall be provided in the minimum number shown in Table 403.1, based on the actual use of the building or space. Uses not shown in Table 403.1 shall be considered individually by the code official. The number of occupants shall be determined by the International Building Code. Action required: Provide drinking fountain or approved equivalent.
IBC 1209.2 Finish materials
Resolved
05/13/2020

2018 IBC 1209.2 Finish Materials. Walls, Floors and partitions in toilet and bathrooms shall comply with Sections 209.2.1 through 1209.2.4. 2018 1209.2.1 Floors and wall bases. In other than dwelling units, toilet, bathing and shower room floor finish materials shall have a smooth, hard, nonabsorbent surface. The intersections of such floors with walls shall have a smooth, hard, nonabsorbent vertical base that extends upward onto the walls not less than 4 inches. 2018 1209.2.2 Walls and partitions. Walls and partitions within 2 feet of service sinks, urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of not less than 4 feet above the floor, and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture. (See code section for possible exceptions.) 1209.2.3 Showers. (see code for details) 1209.2.4 Waterproof joints. (see code for details) Action required: Specify compliant wall finish materials at restrooms and mop sink. If paint is used it must be epoxy based.
Misc
Resolved
05/13/2020

New roof mounted equipment is being installed. Additional information required. Actions required: - Provide verification that there is a convenience receptacle within 25' of new unit per NEC Article 210.63. Provide verification that existing screening is adequate per Unified Development Ordinance Article 8, Section 8.180.E. 5/13/20 - under separate contract/permit - PRCOM20200509
IBC 1008.3 Emergency power for illumination - at exit discharge
Resolved
05/13/2020

2018 IBC 1008.3 Emergency power for illumination. The power supply for means of egress illumination shall normally be provided by the premises’ electrical supply. 1008.3.1 General. In the event of power supply failure in rooms and spaces that require two or more means of egress, an emergency electrical system shall automatically illuminate all of the following areas: 1. Aisles. 2. Corridors. 3. Exit access stairways and ramps. 1008.3.2 Buildings. In the event of power supply failure in buildings that require two or more means of egress, an emergency electrical system shall automatically illuminate all of the following areas: 1. Interior exit access stairways and ramps. 2. Interior and exterior exit stairways and ramps. 3. Exit passageways. 4. Vestibules and areas on the level of discharge used for exit discharge in accordance with Section 1028.1. 5. Exterior landings as required by Section 1010.1.6 for exit doorways that lead directly to the exit discharge. 1008.3.3 Rooms and Spaces. In the event of power supply failure an emergency electrical system shall automatically illuminate all of the following areas: 1. Electrical equipment rooms. 2. Fire command centers. 3. Fire pump rooms. 4. Generator rooms. 5. Public restrooms with an area greater than 300 square feet. Action required: Provide emergency lighting at exterior side of exits.
Licensed Contractors Approved 05/19/2020 05/13/2020
Joe Frogge
Fire Plan Review Approved with Conditions 05/19/2020 05/12/2020
Michael Weissenbach
Address numbers required
Corrective Action Required
05/12/2020

2018 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). (Verified At Inspection) Address all exterior exit doors.
Portable fire extinguishers - conspicuous locations
Corrective Action Required
05/12/2020

2018 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (Verified At Inspection) Provide 2 2A10BC Fire Extinguishers
Illumination required
Resolved
05/12/2020

2018 IFC 1008.1 Illumination required. The means of egress, shall be illuminated at all times the building space served by the means of egress is occupied. (Action Required) Provide exterior emergency illumination at exit doors.
Miscellaneous Correction
Resolved
05/12/2020

(ACTION REQUIRED) IFC 2018 Section 1006 Provide additional exit for Retail Floor and Waiting Room(Occupant load exceeds 49)
Building Plan Review Rejected 05/14/2020 05/06/2020
Joe Frogge
Miscellaneous Correction
Corrective Action Required
05/06/2020

A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit. Action required: Comment is for informational purposes.
Suite address
Corrective Action Required
05/06/2020

This structure has been assigned one address. All suites/apartments shall be assigned an address by the owner which can be numeric, alphabetic or a combination of both. If the building has multiple stories the suite/apartment number shall start with a number representing the floor on which the unit is located. Action required: Verify address and update records. Drawing G02 seems to indicate that this suite is the southernmost so would be 1041 NE Sam Walton Ln, Unit:A but the drawings look like this may be suite B. Also, the door to the north of Game Stop has a Fresh Green sign.
IBC 602.1 Type of Construction - general
Corrective Action Required
05/06/2020

2018 IBC 602.1 General. Buildings and structures erected or to be erected, altered or extended in height or area shall be classified in one of the five construction types defined in Sections 602.2 through 602.5. the building elements shall have a fire-resistance rating not less than that specified in Table 601 and exterior walls shall have a fire resistance rating not less than that specified in Table 602. Where required to have a fire-resistance rating by Table 601, building elements shall comply with the applicable provisions of Section 703.2. The protection for openings, ducts and air transfer openings in building elements shall not be required unless required by other provisions of this code. Action required: Update drawings to show correct building type which is Type 5B. (fyi- this is shown in multiple locations)
IBC 1004.1 Design occupant load
Corrective Action Required
05/06/2020

2018 IBC 1004.1 Design occupant load. In determining means of egress requirements, the number of occupants for whom means of egress facilities shall be provided shall be determined in accordance with this section. Action required: Update drawings to show occupant load of 1 person per 7 square feet in waiting area.
IBC 1004.2.1 Intervening spaces or accessory areas
Corrective Action Required
05/06/2020

2018 IBC 1004.2.1 Intervening spaces or accessory areas. Where occupants egress from one or more rooms, areas or spaces though others, the design occupant load shall be the combined occupant load of interconnected accessory or intervening spaces. Design of egress path capacity shall be based on the cumulative portion of occupant loads of all rooms, areas or spaces to that point along the path of egress travel. Action required: Modify design to provide 2 exits out of Waiting Area. Occupant load is cumulative, i.e. must include Retail area also.
IBC 2902.2 Separate facilities - fixture
Corrective Action Required
05/06/2020

2018 IBC 2902.2 Separate Facilities. Where plumbing fixtures are required, separate facilities shall be provided for each sex. (see code for exceptions) Action required: Comment is for informational purposes. Previous comments may increase occupant load to greater than 100 which would require patron access to second restroom.
IBC 1004.9 Posting of occupant load
Corrective Action Required
05/06/2020

2018 IBC 1004.9 Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space for the intended configurations. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. Action required: Maximum occupancy posting required in Waiting area.
IPC 403.1 Minimum number of fixtures
Corrective Action Required
05/06/2020

2018 IPC 403.1 Minimum number of fixtures. Plumbing fixtures shall be provided in the minimum number shown in Table 403.1, based on the actual use of the building or space. Uses not shown in Table 403.1 shall be considered individually by the code official. The number of occupants shall be determined by the International Building Code. Action required: Provide drinking fountain or approved equivalent.
IBC 1209.2 Finish materials
Corrective Action Required
05/06/2020

2018 IBC 1209.2 Finish Materials. Walls, Floors and partitions in toilet and bathrooms shall comply with Sections 209.2.1 through 1209.2.4. 2018 1209.2.1 Floors and wall bases. In other than dwelling units, toilet, bathing and shower room floor finish materials shall have a smooth, hard, nonabsorbent surface. The intersections of such floors with walls shall have a smooth, hard, nonabsorbent vertical base that extends upward onto the walls not less than 4 inches. 2018 1209.2.2 Walls and partitions. Walls and partitions within 2 feet of service sinks, urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of not less than 4 feet above the floor, and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture. (See code section for possible exceptions.) 1209.2.3 Showers. (see code for details) 1209.2.4 Waterproof joints. (see code for details) Action required: Specify compliant wall finish materials at restrooms and mop sink. If paint is used it must be epoxy based.
Misc
Corrective Action Required
05/06/2020

New roof mounted equipment is being installed. Additional information required. Actions required: - Provide verification that there is a convenience receptacle within 25' of new unit per NEC Article 210.63. Provide verification that existing screening is adequate per Unified Development Ordinance Article 8, Section 8.180.E.
IBC 1008.3 Emergency power for illumination - at exit discharge
Corrective Action Required
05/06/2020

2018 IBC 1008.3 Emergency power for illumination. The power supply for means of egress illumination shall normally be provided by the premises’ electrical supply. 1008.3.1 General. In the event of power supply failure in rooms and spaces that require two or more means of egress, an emergency electrical system shall automatically illuminate all of the following areas: 1. Aisles. 2. Corridors. 3. Exit access stairways and ramps. 1008.3.2 Buildings. In the event of power supply failure in buildings that require two or more means of egress, an emergency electrical system shall automatically illuminate all of the following areas: 1. Interior exit access stairways and ramps. 2. Interior and exterior exit stairways and ramps. 3. Exit passageways. 4. Vestibules and areas on the level of discharge used for exit discharge in accordance with Section 1028.1. 5. Exterior landings as required by Section 1010.1.6 for exit doorways that lead directly to the exit discharge. 1008.3.3 Rooms and Spaces. In the event of power supply failure an emergency electrical system shall automatically illuminate all of the following areas: 1. Electrical equipment rooms. 2. Fire command centers. 3. Fire pump rooms. 4. Generator rooms. 5. Public restrooms with an area greater than 300 square feet. Action required: Provide emergency lighting at exterior side of exits.
Zoning Review Approved 05/14/2020 05/06/2020
Joe Frogge
see email attached herein
Fire Plan Review Rejected 05/14/2020 05/06/2020
Michael Weissenbach
Address numbers required
Corrective Action Required
05/05/2020

2018 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). (Verified At Inspection) Address all exterior exit doors.
Portable fire extinguishers - conspicuous locations
Corrective Action Required
05/05/2020

2018 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (Verified At Inspection) Provide 2 2A10BC Fire Extinguishers
Illumination required
Corrective Action Required
05/05/2020

2018 IFC 1008.1 Illumination required. The means of egress, shall be illuminated at all times the building space served by the means of egress is occupied. (Action Required) Provide exterior emergency illumination at exit doors.
Miscellaneous Correction
Corrective Action Required
05/06/2020

(ACTION REQUIRED) IFC 2018 Section 1006 Provide additional exit for Retail Floor and Waiting Room(Occupant load exceeds 49)
Licensed Contractors Approved 05/14/2020 05/06/2020
Joe Frogge
Licensed Contractors Approved 05/14/2020 05/04/2020
Joe Frogge
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Change of Tenant $230.97 $230.97 Paid 05/14/2020
$0.00
7232302-Commercial License Tax Fee $5,722.50 $5,722.50 Paid 05/14/2020
$5,722.50
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
In-wall Inspection Failed 6/16/2020 6/16/2020 06/16/2020
Misc
Corrective Action Required
06/16/2020
Porter Elect is now doing the work ok to proceed
In-wall Inspection Failed 6/29/2020 6/29/2020 06/29/2020
Misc
Corrective Action Required
06/16/2020
no inspections until Electrical contractor is verified. Porter Elect - is not the electrical contractor.
Miscellaneous Correction
Corrective Action Required
06/29/2020
-SEAL HOLES IN EXISTING DEMISING WALL -MISSING WIRE CLIPS AND RECEPTACLE BOXES -MOVE JUNCTION BOXES TO BE OUTSIDE OF WALLS AND ACCESSIBLE AFTER FINISH
In-wall Inspection Failed 6/30/2020 6/30/2020 06/30/2020
Misc
Resolved
06/30/2020
no inspections until Electrical contractor is verified. Porter Elect - is not the electrical contractor.
Miscellaneous Correction
Corrective Action Required
06/29/2020
-MISSING WIRE CLIPS AT RECEPTACLE BOXES -MOVE JUNCTION BOXES OR ADD MUD RINGS TO BE OUTSIDE OF WALLS AND ACCESSIBLE AFTER FINISH -ALL WOOD BLOCKING TO BE FIRE TREATED -All WALL TYPE 1 TO BE FULL HEIGHT AND HAVE HORIZONTAL STUDS EVERY 16”
In-wall Inspection Passed 7/1/2020 7/1/2020 07/01/2020
Miscellaneous Correction
Resolved
07/01/2020
-OK TO ROCK EXCEPT REMAINING WALL TO BE CORRECTED- -MOVE JUNCTION BOXES OR ADD MUD RINGS TO BE ON OUTSIDE OF WALLS AND ACCESSIBLE AFTER FINISH-2 ON BACK WALL ADJACENT TO BATHROOM.
Occupancy Inspection - Fire Passed 9/9/2020 9/9/2020 09/09/2020
Occupancy Inspection - Codes Commercial Failed 9/9/2020 9/9/2020 09/09/2020
Miscellaneous Correction
Corrective Action Required
09/09/2020
-LABEL ELECTRICAL PANEL -PROVIDE ADA ACCESSIBILITY IN BREAK ROOM -MOVE BATHROOM SIGNS TO LATCH SIDE -PROVIDE OPEN TOILET SEAT IN ADA BATHROOM -PROVIDE INSULATION BIB ON PIPE IN AFA BATHROOM -ADD ADA COUNTERTOP FOR P.O.S.
All Rough Inspection - Commercial Passed 09/11/2020
Above Ceiling Inspection Passed 09/11/2020
Occupancy Inspection - Codes Commercial Full C of O 9/11/2020 9/11/2020 09/11/2020
Miscellaneous Correction
Resolved
09/11/2020
-LABEL ELECTRICAL PANEL -PROVIDE ADA ACCESSIBILITY IN BREAK ROOM -MOVE BATHROOM SIGNS TO LATCH SIDE -PROVIDE OPEN TOILET SEAT IN ADA BATHROOM -PROVIDE INSULATION BIB ON PIPE IN AFA BATHROOM -ADD ADA COUNTERTOP FOR P.O.S.
Documents & Images
Date Uploaded File Type Document Name
05/04/2020 Application Form Fresh Green, LLC Building Permit Application
05/04/2020 Plans 2020-017 - Fresh Green Lees Summit - 100% CD for Permit
05/06/2020 Letter License Tax Bill
05/06/2020 Email zoning letter
05/06/2020 Letter Fire Building Plan Review
05/06/2020 Letter DS P/R Corrections Document
05/12/2020 Letter Response Letter
05/12/2020 Plans Resub plans
05/12/2020 Letter Fire Building Plan Review
05/14/2020 Application Form Lee's Summit Excise Tax Form
05/14/2020 Approved Plans Approved set - Fresh Green Lees Summit
05/14/2020 Receipt Receipt for transaction:2020-002142
05/14/2020 Letter DS Building Permit
06/16/2020 Letter INSPECTION SUMMARY
06/29/2020 Letter INSPECTION SUMMARY
06/29/2020 Letter Codes Plan Review Conditions
06/30/2020 Letter INSPECTION SUMMARY
06/30/2020 Engineer Report/Study HIVE Inspection Letter (signed)
07/01/2020 Letter INSPECTION SUMMARY
09/09/2020 Letter INSPECTION SUMMARY
09/11/2020 Letter INSPECTION SUMMARY
09/11/2020 Letter INSPECTION SUMMARY
09/11/2020 Letter INSPECTION SUMMARY
09/11/2020 Letter Codes Final Certificate of Occupancy
09/11/2020 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home