Permit Application Status

PRCOM20172535


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20172535
Building Permit - Commercial
Certificate of Occupancy
PARROT PROPERTIES INC
NEW MULTI-FAMILY
NEW 2 STORY APARTMENT BUILDING WITH PARKING GARAGE BENEATH FOUNDATION PERMIT - PRCOM20181913
07/24/2017
12/06/2019
01/13/2021
Locations
Contacts
CITYSCAPE CONSTRUCTION VIEW HIGH LLC, Address:10 W CARMEL DR STE 200, Phone:(317) 574-1600 Ext:100  
STANDARD HEATING & COOLING TOO LLC, Address:2006 E PRAIRIE CIRCLE , Phone:(913) 782-5409  
STANDARD ELECTRIC COMPANY INC, Address:2006 E PRAIRIE CIRCLE, Phone:(913) 782-5409  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
SGN+A ARCHITECTS, Address:315 W PONCE DE LEON AVE #755, Phone:(404) 373-7370  
LATIMER SOMMERS & ASSOCIATES PA, Address:3639 SW SUMMERFIELD DR STE A, Phone:(785) 233-3232  
PARROT PROPERTIES INC, Address:11303 VIEW HIGH DR  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 08/07/2018 06/19/2018
Joe Frogge
Final Development Plan Review Approved 08/07/2018 02/16/2018
Joe Frogge
Building Plan Review Approved 08/07/2018 02/16/2018
Joe Frogge
Special Inspections Review Approved 08/07/2017 08/24/2017
Joe Frogge
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New Multi-Family $11,870.07 $11,870.07 Paid 12/06/2019
8331507-Sewer Connection Fee $3,000.00 $3,000.00 Paid 12/06/2019
Not Ready Inspection Fee $50.00 $50.00 Paid 12/01/2020
Outstanding Fees Amount Paid Owing Date Paid


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Commercial Passed 12/10/2019 12/10/2019 12/10/2019
Footing Inspection - Commercial Partial 12/20/2019 (3:00) 12/20/2019 12/20/2019
All Rough Inspection - Commercial Failed 4/2/2020 4/2/2020 04/02/2020
THIRD FLOOR
Corrective Action Required
04/02/2020
BLDG # 17 WEST END - - 312 FIRE CAULK BORE BOTTOM PLATE BED NEAR PATIO - - 310 FIRE CAULK BORES BOTTOM PLATE AT TUB & BED CLOSET - RC CHANNEL COMPLETE IN UNITS NOT DONE ABOVE FRONT ENTRY & STAIRS -
SECOND FLOOR
Corrective Action Required
04/02/2020
BLDG # 17 WEST END - - 211 FIRE CAULK TOP PLATE ABOVE SERVICE PANEL,MECH CLOSET DWV LINE CUT AT HVAC, - - 212 NAIL GUARD KITCHEN ISLAND, FIRE CAULK 4" LINE IN DEAD SPACE - - 210 FIRE CAULK 4" LINE IN DEAD SPACE, PATCH HOLE IN SHEAR WALL BETWEEN JOIST IN BEDROOM, NAIL GAURD KITCHEN ISLAND, FC SPRINKLER IN LAUNDRY, DWV CUT AT HVAC IN MECH CLOSET - - 209 FC TOP PLATE COAT CLOSET, FC TOP PLATE & PATCH HOLE COMMON WALL KITCHEN/LIVING ROOM -
FIRST FLOOR
Corrective Action Required
04/02/2020
BLDG # 17 WEST END GARAGE 15 & 16 FURR OUT @ DRAINS
All Rough Inspection - Commercial Failed 4/3/2020 04/03/2020
THIRD FLOOR
Corrective Action Required
04/02/2020
BLDG # 17 WEST END - - 312 FIRE CAULK BORE BOTTOM PLATE BED NEAR PATIO - - 310 FIRE CAULK BORES BOTTOM PLATE AT TUB & BED CLOSET - RC CHANNEL COMPLETE IN UNITS NOT DONE ABOVE FRONT ENTRY & STAIRS - - NW 307 DEAD SPACE DRYER BOX - - NE 305 SEPERATION OF UNITS IN ATTIC INCOMPLETE, ELECTRICAL PLATES NORTH BEDROOM - - SE 306 4" DWV FIRE COLLAR - - SW 308 PLUMBING PLATES TUB WALL ST CLOSET - - CENTER ENTRY H 2.5S MISSING - - DRAFT STOP BETWEEN UNITS , ATTIC SPACE NEEDS DRAFT STOP WHERE REQUIRED -
SECOND FLOOR
Corrective Action Required
04/02/2020
BLDG # 17 WEST END - - ELECTRICAL NOT STUBBED OUT FOR A/C UNITS- - 211 FIRE CAULK TOP PLATE ABOVE SERVICE PANEL,MECH CLOSET DWV LINE CUT AT HVAC, - - 212 NAIL GUARD KITCHEN ISLAND, FIRE CAULK 4" LINE IN DEAD SPACE - - 210 FIRE COLLARS ON ALL 4" DWV AT CEILING-, PATCH HOLE IN SHEAR WALL BETWEEN JOIST IN BEDROOM, NAIL GAURD KITCHEN ISLAND, FC SPRINKLER IN LAUNDRY, DWV CUT AT HVAC IN MECH CLOSET - - PLUMBING PLATES - ALL DRYER BOXES INCOMPLETE- DEAD SPACES NOT CAULKED- NAIL PATTERN ON SHEETROCK IN HEAT CHASE CORRIDORS- - 209 FC TOP PLATE COAT CLOSET, FC TOP PLATE & PATCH HOLE COMMON WALL KITCHEN/LIVING ROOM - - 208 DRAFT STOP FOR DDL WALL NOT SEALED, DEAD SPACE ROCK INCOMPLETE, CAN NOT ACCESS BATHROOM FOR TUB STUCK IN DOOR, BROKEN STUD CORRIDOR WALL, 2 BOXES SAME STUD BAY AT SAME WALL NEEDS PUTTY PADS- - 207 dryer boxes, SE cables not caulked - - 205 holes in top plate not caulked, dryer boxes, protection plate for sprinkler line bed wall at bathroom, Seperation between units incomplete - -
FIRST FLOOR
Corrective Action Required
04/02/2020
BLDG # 17 WEST END GARAGE 15 SERVICE ENTRY CABLE NEEDS SUPPORTED OVER GARAGE AND ELEC ROOM, SUPPORT DWV, 4" FIRE COLLARS, - 16 SUPPORT DWV, 4" FIRE COLLARS - - PLUMBING PLATES AT CORRIDOR WALL BOTTOM PLATE - - GARAGE 9 SUPPORT DWV , 4" COLLAR - - GARAGE 10 SUPPORT DWV, 4" ,COLLAR - - PROVIDE 6'8" HEAD ROOM HEIGHT ON ALL STAIRS TO LOWER LEVEL FROM 1ST FLOOR - - DRAFT STOP GARAGE JOIST SPACE AT 1000 SQ FT -
All Rough Inspection - Commercial Failed 4/6/2020 04/06/2020
THIRD FLOOR
Corrective Action Required
04/03/2020
BLDG # 17 WEST END - - 312 FIRE CAULK BORE BOTTOM PLATE BED NEAR PATIO - - 310 FIRE CAULK BORES BOTTOM PLATE AT TUB & BED CLOSET - RC CHANNEL COMPLETE IN UNITS NOT DONE ABOVE FRONT ENTRY & STAIRS - - NW 307 DEAD SPACE DRYER BOX - - NE 305 SEPERATION OF UNITS IN ATTIC INCOMPLETE, ELECTRICAL PLATES NORTH BEDROOM - - SE 306 4" DWV FIRE COLLAR - - SW 308 PLUMBING PLATES TUB WALL ST CLOSET - - CENTER ENTRY H 2.5S MISSING - - DRAFT STOP BETWEEN UNITS , ATTIC SPACE NEEDS DRAFT STOP WHERE REQUIRED - - 303 FIRE CAULK DRAFT STOP, FC BORES BOTTOM PLATE KITCHEN, FC MECHANICAL CLOSET, FC BOTTOM PLATE KITCHEN AT DBL WALL, - - 304 FC BOTTOM PLATE LAUNDRY, FIRE COLLAR DEAD SPACE - - 302 FIRE COLLAR DEAD SPACE -
SECOND FLOOR
Corrective Action Required
04/03/2020
BLDG # 17 WEST END - - ELECTRICAL NOT STUBBED OUT FOR A/C UNITS- - 211 FIRE CAULK TOP PLATE ABOVE SERVICE PANEL,MECH CLOSET DWV LINE CUT AT HVAC, - - 212 NAIL GUARD KITCHEN ISLAND, FIRE CAULK 4" LINE IN DEAD SPACE - - 210 FIRE COLLARS ON ALL 4" DWV AT CEILING-, PATCH HOLE IN SHEAR WALL BETWEEN JOIST IN BEDROOM, NAIL GAURD KITCHEN ISLAND, FC SPRINKLER IN LAUNDRY, DWV CUT AT HVAC IN MECH CLOSET - - PLUMBING PLATES - ALL DRYER BOXES INCOMPLETE- DEAD SPACES NOT CAULKED- NAIL PATTERN ON SHEETROCK IN HEAT CHASE CORRIDORS- - 209 FC TOP PLATE COAT CLOSET, FC TOP PLATE & PATCH HOLE COMMON WALL KITCHEN/LIVING ROOM - - 208 DRAFT STOP FOR DDL WALL NOT SEALED, DEAD SPACE ROCK INCOMPLETE, CAN NOT ACCESS BATHROOM FOR TUB STUCK IN DOOR, BROKEN STUD CORRIDOR WALL, 2 BOXES SAME STUD BAY AT SAME WALL NEEDS PUTTY PADS- - 207 dryer boxes, SE cables not caulked - - 205 holes in top plate not caulked, dryer boxes, protection plate for sprinkler line bed wall at bathroom, Seperation between units incomplete - -
FIRST FLOOR
Corrective Action Required
04/03/2020
BLDG # 17 WEST END GARAGE 15 SERVICE ENTRY CABLE NEEDS SUPPORTED OVER GARAGE AND ELEC ROOM, SUPPORT DWV, 4" FIRE COLLARS, - 16 SUPPORT DWV, 4" FIRE COLLARS - - PLUMBING PLATES AT CORRIDOR WALL BOTTOM PLATE - - GARAGE 9 SUPPORT DWV , 4" COLLAR - - GARAGE 10 SUPPORT DWV, 4" ,COLLAR - - PROVIDE 6'8" HEAD ROOM HEIGHT ON ALL STAIRS TO LOWER LEVEL FROM 1ST FLOOR - - DRAFT STOP GARAGE JOIST SPACE AT 1000 SQ FT -
All Rough Inspection - Commercial Failed 4/7/2020 04/07/2020
SECOND FLOOR
Corrective Action Required
04/06/2020
BLDG # 17 WEST END - - ELECTRICAL NOT STUBBED OUT FOR A/C UNITS- - 211 FIRE CAULK TOP PLATE ABOVE SERVICE PANEL,MECH CLOSET DWV LINE CUT AT HVAC, - - 212 NAIL GUARD KITCHEN ISLAND, FIRE CAULK 4" LINE IN DEAD SPACE - - 210 FIRE COLLARS ON ALL 4" DWV AT CEILING-, PATCH HOLE IN SHEAR WALL BETWEEN JOIST IN BEDROOM, NAIL GAURD KITCHEN ISLAND, FC SPRINKLER IN LAUNDRY, DWV CUT AT HVAC IN MECH CLOSET - - PLUMBING PLATES - ALL DRYER BOXES INCOMPLETE- DEAD SPACES NOT CAULKED- NAIL PATTERN ON SHEETROCK IN HEAT CHASE CORRIDORS- - 209 FC TOP PLATE COAT CLOSET, FC TOP PLATE & PATCH HOLE COMMON WALL KITCHEN/LIVING ROOM - - 208 DRAFT STOP FOR DDL WALL NOT SEALED, DEAD SPACE ROCK INCOMPLETE, CAN NOT ACCESS BATHROOM FOR TUB STUCK IN DOOR, BROKEN STUD CORRIDOR WALL, 2 BOXES SAME STUD BAY AT SAME WALL NEEDS PUTTY PADS- - 207 dryer boxes, SE cables not caulked - - 205 holes in top plate not caulked, dryer boxes, protection plate for sprinkler line bed wall at bathroom, Seperation between units incomplete - - - 4/7/20 BLDG 17 2ND FLOOR EAST END - - 203 FIRE CAULK BATH TOP PLATE BORE, TOP PLATE PANTRY RACEWAYS, PUTTY BACK BOX CORNER LIVING ROOM / KITCHEN, DRAFT STOP NOTCHING - - 204 FC SEC AT DRYER VENTS, FIRE COLLAR DEAD SPACE, - - 202 FIRE COLLAR DEAD SPACE, FC BOTH BEDROOM CLOSETS BAD SPRINKLER BORES - - 201 FC BORES UNDER SERVICE PANEL, FIRE COLLAR RISER LINE IN DEAD SPACE - - 2ND TO 3RD FLOOR LANDING H 2.5S AT TRUSSES -
FIRST FLOOR
Corrective Action Required
04/06/2020
BLDG # 17 WEST END GARAGE 15 SERVICE ENTRY CABLE NEEDS SUPPORTED OVER GARAGE AND ELEC ROOM, SUPPORT DWV, 4" FIRE COLLARS, - 16 SUPPORT DWV, 4" FIRE COLLARS - - PLUMBING PLATES AT CORRIDOR WALL BOTTOM PLATE - - GARAGE 9 SUPPORT DWV , 4" COLLAR - - GARAGE 10 SUPPORT DWV, 4" ,COLLAR - - PROVIDE 6'8" HEAD ROOM HEIGHT ON ALL STAIRS TO LOWER LEVEL FROM 1ST FLOOR - - DRAFT STOP GARAGE JOIST SPACE AT 1000 SQ FT - - 4/7/20 1ST FLOOR EAST END - - G1 FIRE CAULK UFERS - - REAR ENTRY H 2.5S TRUSSES
THIRD FLOOR
Corrective Action Required
04/06/2020
BLDG # 17 WEST END - - 312 FIRE CAULK BORE BOTTOM PLATE BED NEAR PATIO - - 310 FIRE CAULK BORES BOTTOM PLATE AT TUB & BED CLOSET - RC CHANNEL COMPLETE IN UNITS NOT DONE ABOVE FRONT ENTRY & STAIRS - - NW 307 DEAD SPACE DRYER BOX - - NE 305 SEPERATION OF UNITS IN ATTIC INCOMPLETE, ELECTRICAL PLATES NORTH BEDROOM - - SE 306 4" DWV FIRE COLLAR - - SW 308 PLUMBING PLATES TUB WALL ST CLOSET - - CENTER ENTRY H 2.5S MISSING - - DRAFT STOP BETWEEN UNITS , ATTIC SPACE NEEDS DRAFT STOP WHERE REQUIRED - - 303 FIRE CAULK DRAFT STOP, FC BORES BOTTOM PLATE KITCHEN, FC MECHANICAL CLOSET, FC BOTTOM PLATE KITCHEN AT DBL WALL, - - 304 FC BOTTOM PLATE LAUNDRY, FIRE COLLAR DEAD SPACE - - 302 FIRE COLLAR DEAD SPACE -
All Rough Inspection - Commercial Partial 4/10/2020 4/10/2020 04/10/2020
SECOND FLOOR
Resolved
04/10/2020
BLDG # 17
FIRST FLOOR
Resolved
08/27/2020
THIRD FLOOR
Resolved
04/10/2020
BLDG # 17 -
Footing Inspection - Commercial Partial 4/21/2020 4/21/2020 04/21/2020
Misc
Informational
04/21/2020
FOOTING FOR RISER ROOM OK TO POUR
Rated Assembly Inspection Failed 4/24/2020 4/24/2020 04/24/2020
Misc
Corrective Action Required
04/24/2020
- COMPLETE RC CHANNEL ELECTRICAL ROOMS -
Rated Assembly Inspection Partial 4/27/2020 4/27/2020 04/27/2020
Misc
Corrective Action Required
04/27/2020
- COMPLETE RC CHANNNEL ELECTRICAL ROOMS - - ALL OTHER AREAS OK TO ROCK -
Rated Assembly Inspection Partial 5/6/2020 5/6/2020 05/06/2020
Misc
Corrective Action Required
04/27/2020
- COMPLETE RC CHANNNEL ELECTRICAL ROOMS - - ALL OTHER AREAS OK TO ROCK - - OK TO TAPE UNITS ONLY GARAGES, CORRIDORS & STAIRWAYS NEED SCREW PATTERN INSPECTION-
Sprinkler - Hydrostatic Test Passed 5/8/2020 05/08/2020
Rated Assembly Inspection Partial 5/15/2020 5/15/2020 05/15/2020
Misc
Corrective Action Required
05/06/2020
- COMPLETE RC CHANNNEL ELECTRICAL ROOMS - - ALL OTHER AREAS OK TO ROCK - - OK TO TAPE UNITS ONLY GARAGES, CORRIDORS & STAIRWAYS NEED SCREW PATTERN INSPECTION-
Misc
Corrective Action Required
05/15/2020
CORRIDORS & STAIRWAYS OK TO TAPE COMPLETE SCREW PATTERN GARAGES ELECTRICAL,IT, RISER ROOMS NEED RC CHANNEL
Rated Assembly Inspection Partial 5/20/2020 5/20/2020 05/20/2020
Misc
Resolved
08/27/2020
Misc
Resolved
08/27/2020
Electrical Service Inspection Passed 5/27/2020 5/27/2020 05/27/2020
Misc
Informational
05/27/2020
28 units 2 house meters
Alarm Test Not Ready 8/19/2020 08/19/2020
Sprinkler - Flow Test Not Ready 8/19/2020 08/19/2020
Alarm Test Passed 8/24/2020 08/24/2020
Sprinkler - Flow Test Passed 8/24/2020 08/24/2020
Rated Assembly Inspection Passed 8/27/2020 08/27/2020
Misc
Corrective Action Required
05/20/2020
- COMPLETE RC CHANNNEL ELECTRICAL ROOMS - - ALL OTHER AREAS OK TO ROCK -
Misc
Corrective Action Required
05/20/2020
GARAGES, CORRIDORS & STAIRWAYS OK TO TAPE ELECTRICAL,IT, RISER ROOMS NEED RC CHANNEL
All Rough Inspection - Commercial Passed 8/27/2020 08/27/2020
FIRST FLOOR
Corrective Action Required
04/10/2020
BLDG # 17 WEST END GARAGE 15 SERVICE ENTRY CABLE NEEDS SUPPORTED OVER GARAGE AND ELEC ROOM, - - PROVIDE 6'8" HEAD ROOM HEIGHT ON ALL STAIRS CHECK ON FINAL - - 4/7/20 1ST FLOOR EAST END -
Rough Electrical Inspection - Commercial Passed 4/10/2020 08/27/2020
Rough Mechanical Inspection - Commercial Passed 4/10/2020 08/27/2020
Rough Plumbing Inspection - Commercial Passed 4/10/2020 08/27/2020
Sewer Service Inspection Passed 8/31/2020 08/31/2020
Water Service Inspection Passed 8/31/2020 08/31/2020
Occupancy Inspection - Planning Temporary C of O 8/31/2020 08/31/2020
Occupancy Inspection - Fire Passed 8/31/2020 8/31/2020 08/31/2020
Occupancy Inspection - Codes Commercial Failed 8/31/2020 8/31/2020 08/31/2020
Misc
Corrective Action Required
08/31/2020
BLDG # 17 - WEST END - -212 FIRE CAULK HVAC CEILING MECHANICAL ROOM - - 208 FIRE CAULK HVAC CEILING MECHANICAL ROOM- - EAST END - - SEAL PENETRATIONS MECHANICAL ROOMS - - PROVIDE TAMPER PROOF CAPS AC CONDENSORS- - COMPLETE DOWNSPOUTS - - FIRE ALARM ROOM MISSING SPRINKLER ESCUTCHEON -
Piers/Caissons Inspection - Commercial Passed 9/1/2020 09/01/2020
Misc
Informational
09/01/2020
- LIGHT POLE BASE -
Final Plumbing Inspection - Commercial Passed 9/2/2020 09/02/2020
Footing Inspection - Commercial Passed 9/2/2020 09/02/2020
Misc
Informational
04/21/2020
FOOTING FOR RISER ROOM OK TO POUR
Occupancy Inspection - Codes Commercial Temporary C of O 9/2/2020 09/02/2020
Misc
Corrective Action Required
08/31/2020
BLDG # 17 - PROVIDE TAMPER PROOF CAPS AC CONDENSORS- - COMPLETE DOWNSPOUTS - - UNDERGROUND ELECTRIC FOR LIGHT POLE BASE -
Occupancy Inspection - Water Utilities Passed 8/31/2020 10/05/2020
Occupancy Inspection - Planning Passed 11/5/2020 11/05/2020
Underground Electrical Inspection - Commercial Partial 11/18/2020 11/18/2020 11/18/2020
Misc
Informational
11/18/2020
UG electric for lot lighting approved for island at maintenance building
Misc
Corrective Action Required
11/18/2020
-uncover UG electric for monument sign
Occupancy Inspection - Engineering Passed 1/13/2021 01/13/2021
Misc
Informational
01/13/2021
I am good for final occupancy.
Occupancy Inspection - Codes Commercial Full C of O 1/13/2021 1/13/2021 01/13/2021
Misc
Resolved
01/13/2021
BLDG # 17 - PROVIDE TAMPER PROOF CAPS AC CONDENSORS- - COMPLETE DOWNSPOUTS - - UNDERGROUND ELECTRIC FOR LIGHT POLE BASE -
Documents & Images
Date Uploaded File Type Document Name
10/16/2017 Meridian Site Map
12/06/2019 Letter DS Building Permit
12/10/2019 Letter INSPECTION SUMMARY
12/20/2019 Letter INSPECTION SUMMARY
04/02/2020 Letter INSPECTION SUMMARY
04/03/2020 Letter INSPECTION SUMMARY
04/06/2020 Letter INSPECTION SUMMARY
04/07/2020 Letter INSPECTION SUMMARY
04/10/2020 Letter INSPECTION SUMMARY
04/21/2020 Letter INSPECTION SUMMARY
04/24/2020 Letter INSPECTION SUMMARY
04/27/2020 Letter INSPECTION SUMMARY
05/15/2020 Letter INSPECTION SUMMARY
05/20/2020 Letter INSPECTION SUMMARY
05/27/2020 Letter INSPECTION SUMMARY
05/27/2020 Letter INSPECTION SUMMARY
08/31/2020 Letter INSPECTION SUMMARY
09/02/2020 Letter Codes Temporary Certificate of Occupancy
11/18/2020 Letter INSPECTION SUMMARY
12/01/2020 Receipt Receipt for transaction:2020-007800
01/13/2021 Letter Codes Final Certificate of Occupancy
01/13/2021 Letter Field Certificate of Occupancy
01/13/2021 Letter DE-Daily Inspection Summary
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home