Permit Application Status

PRCOM20171395


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20171395
Building Permit - Commercial
Certificate of Occupancy
BEARS WILLIAM L JR & CONNIE - TRUSTEE
CHANGE OF TENANT
TENANT FINISH FOR NEW MED SPA
05/03/2017
09/29/2017
12/03/2017
06/16/2020
Locations
Contacts
THE ISLAS FAM, Address:106 S VERMONT, Phone:(816) 835-9753  
THE ISLAS FAM, Address:106 S VERMONT, Phone:(816) 835-9753  
JOHNSON & SON'S PLUMBING LLC, Address:810 NW HAWTHORN CT, Phone:(816) 868-7960  
DBL ARCHITECTURE + INC, Address:8031 WENONGA RD, Phone:(913) 383-8928  
SALAZAR GENERAL CONTRACTOR INC, Address:1303 CENTRAL AVE, Phone:(913) 428-5479  
BEARS WILLIAM L JR & CONNIE - TRUSTEE, Address:13906 KENNEDY RD  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 06/28/2017 09/28/2017
Development Center
LC - General Contractor
Resolved
09/28/2017

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the name of the licensed general contractor.
LC - MEP Subs
Resolved
09/28/2017

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Fire Plan Review Approved with Conditions 07/06/2017 07/03/2017
Joe Dir
Address numbers required
Corrective Action Required
06/28/2017

2012IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). ACTION REQUIRED: (verified at inspection) Address shall be viewable from the roadway 3rd St.
Portable fire extinguishers - general
Corrective Action Required
06/28/2017

2012 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. ACTION REQUIRED: (verified at inspection) Provide one 2A-10BC fire extinguisher to be mounted on a normal path of travel close to an exit.
Building Plan Review Approved with Conditions 07/06/2017 06/29/2017
Joe Frogge
License Tax Application
Corrective Action Required
06/28/2017

A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit. Action required: Comment is for informational purposes. 6/6/17 - Acknowledged in letter
Accessibility - Swinging doors - maneuvering clearance 404.2.3.2
Resolved
06/29/2017

ICC A117.1-2009 Section 404.2.3.2 Swinging Doors. Swinging doors shall have maneuvering clearances complying with Table 404.2.3.2. Action required: Provide minimum 18" clearance at latch side of door D03, D09, & D10. 6/6/17 - Only provided at D10 - now also required at D06
Building Plan Review Rejected 06/07/2017 06/06/2017
Joe Frogge
License Tax Application
Corrective Action Required
05/31/2017

A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit. Action required: Comment is for informational purposes. 6/6/17 - Acknowledged in letter
Code analysis required
Resolved
06/06/2017

A code analysis shall be provided which includes but is not limited to occupancy type, occupant load, construction type, actual area, height and floors, allowable area, height and floors, and the codes to which the project is designed. Action required: Update code analysis to show appropriate occupant load. I have calculated 15 people.
Accessibility - Swinging doors - maneuvering clearance 404.2.3.2
Corrective Action Required
05/31/2017

ICC A117.1-2009 Section 404.2.3.2 Swinging Doors. Swinging doors shall have maneuvering clearances complying with Table 404.2.3.2. Action required: Provide minimum 18" clearance at latch side of door D03, D09, & D10. 6/6/17 - Only provided at D10 - now also required at D06
Misc
Resolved
06/06/2017

2012 IBC 1006.1 Illumination required. The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. Action required: Where exit lighting is provided, emergency lighting must be provided at exterior side of exit door.
Plumb - Minimum number of fixtures 403.1
Resolved
06/06/2017

2012 IPC 403.1 – Minimum number of fixtures. Plumbing fixtures shall be provided for the type of occupancy and in the minimum number shown in Table 403.1. types of occupancies not shown in Table 403.1 shall be considered individually by the code official. The number of occupants shall be determined by the International Building Code. Occupancy classification shall be determined in accordance with the International Building Code. Action required: Provide mop sink.
Bldg - Accessibility - Point of sales and service counters 1109.12.3
Resolved
06/06/2017

2012 IBC 1109.12.3 – Point of sale and service counters. Where counters are provided for sales or distribution of goods or services, at least one of each type provided shall be accessible. Where such counters are dispersed throughout the building or facility, accessible counters shall also be dispersed. Action required: Provide at least 36" of countertop that is no higher than 36" at reception counter.
Misc
Resolved
06/06/2017

2011 NEC 517.13 Grounding of Receptacles and Fixed Electrical Equipment in Patient Care Areas. Wiring in patient care areas shall comply with 517.13(A) and (B). (A) Wiring methods. All branch circuits serving patient care areas shall be provided with an effective ground-fault current path by installation in a metal raceway system, or a cable having a metallic armor or sheath assembly. The metal raceway system, or metallic cable armor, or sheath assembly shall itself qualify as an equipment grounding conductor in accordance with 250.118. (B) Insulated Equipment Grounding Conductor. (1) General. The following shall be directly connected to an insulated copper equipment grounding conductor that is installed with the branch circuit conductors in the wiring methods as provided in 517.13(A). 1. The grounding terminals of all receptacles. 2. Metal Boxes and enclosures containing receptacles. 3. All non-current-carrying conductive surfaces of fixed electrical equipment likely to become energized that are subject to personal contact, operating at over 100 volts. (refer code for exceptions) (2) Sizing. Equipment grounding conductors and equipment bonding jumpers shall be sized in accordance with 250.122. Action required: Modify drawings to show that all circuits in patient care areas will have redundant ground system.
Misc
Resolved
06/06/2017

Additional information required to complete review. Provide the following: - Electrical specifications. (methods and materials) - Pipe material schedule. - Where is condensing unit? Locate on drawings to verify screening and convenience power as well as any structural requirements.
Licensed Contractors Rejected 05/31/2017 06/06/2017
Joe Frogge
LC - General Contractor
Corrective Action Required
05/31/2017

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the name of the licensed general contractor.
LC - MEP Subs
Corrective Action Required
05/31/2017

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Fire Plan Review Approved with Conditions 06/07/2017 06/05/2017
Joe Dir
Address numbers required
Corrective Action Required
05/31/2017

2012IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). ACTION REQUIRED: (verified at inspection) Address shall be viewable from the roadway 3rd St.
Portable fire extinguishers - general
Corrective Action Required
05/31/2017

2012 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. ACTION REQUIRED: (verified at inspection) Provide one 2A-10BC fire extinguisher to be mounted on a normal path of travel close to an exit.
Building Plan Review Rejected 05/15/2017 05/05/2017
Joe Frogge
License Tax Application
Corrective Action Required
05/05/2017

A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit. Action required: Comment is for informational purposes.
Code analysis required
Corrective Action Required
05/05/2017

A code analysis shall be provided which includes but is not limited to occupancy type, occupant load, construction type, actual area, height and floors, allowable area, height and floors, and the codes to which the project is designed. Action required: Update code analysis to show appropriate occupant load. I have calculated 15 people.
Accessibility - Swinging doors - maneuvering clearance 404.2.3.2
Corrective Action Required
05/05/2017

ICC A117.1-2009 Section 404.2.3.2 Swinging Doors. Swinging doors shall have maneuvering clearances complying with Table 404.2.3.2. Action required: Provide minimum 18" clearance at latch side of door D03, D09, & D10.
Misc
Corrective Action Required
05/05/2017

2012 IBC 1006.1 Illumination required. The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. Action required: Where exit lighting is provided, emergency lighting must be provided at exterior side of exit door.
Plumb - Minimum number of fixtures 403.1
Corrective Action Required
05/05/2017

2012 IPC 403.1 – Minimum number of fixtures. Plumbing fixtures shall be provided for the type of occupancy and in the minimum number shown in Table 403.1. types of occupancies not shown in Table 403.1 shall be considered individually by the code official. The number of occupants shall be determined by the International Building Code. Occupancy classification shall be determined in accordance with the International Building Code. Action required: Provide mop sink.
Bldg - Accessibility - Point of sales and service counters 1109.12.3
Corrective Action Required
05/05/2017

2012 IBC 1109.12.3 – Point of sale and service counters. Where counters are provided for sales or distribution of goods or services, at least one of each type provided shall be accessible. Where such counters are dispersed throughout the building or facility, accessible counters shall also be dispersed. Action required: Provide at least 36" of countertop that is no higher than 36" at reception counter.
Misc
Corrective Action Required
05/05/2017

2011 NEC 517.13 Grounding of Receptacles and Fixed Electrical Equipment in Patient Care Areas. Wiring in patient care areas shall comply with 517.13(A) and (B). (A) Wiring methods. All branch circuits serving patient care areas shall be provided with an effective ground-fault current path by installation in a metal raceway system, or a cable having a metallic armor or sheath assembly. The metal raceway system, or metallic cable armor, or sheath assembly shall itself qualify as an equipment grounding conductor in accordance with 250.118. (B) Insulated Equipment Grounding Conductor. (1) General. The following shall be directly connected to an insulated copper equipment grounding conductor that is installed with the branch circuit conductors in the wiring methods as provided in 517.13(A). 1. The grounding terminals of all receptacles. 2. Metal Boxes and enclosures containing receptacles. 3. All non-current-carrying conductive surfaces of fixed electrical equipment likely to become energized that are subject to personal contact, operating at over 100 volts. (refer code for exceptions) (2) Sizing. Equipment grounding conductors and equipment bonding jumpers shall be sized in accordance with 250.122. Action required: Modify drawings to show that all circuits in patient care areas will have redundant ground system.
Misc
Corrective Action Required
05/05/2017

Additional information required to complete review. Provide the following: - Electrical specifications. (methods and materials) - Pipe material schedule. - Where is condensing unit? Locate on drawings to verify screening and convenience power as well as any structural requirements.
Licensed Contractors Rejected 05/15/2017 05/05/2017
Joe Frogge
LC - General Contractor
Corrective Action Required
05/05/2017

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the name of the licensed general contractor.
LC - MEP Subs
Corrective Action Required
05/05/2017

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Fire Plan Review Approved with Conditions 05/15/2017 05/04/2017
Joe Dir
Address numbers required
Corrective Action Required
05/04/2017

2012IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). ACTION REQUIRED: (verified at inspection) Address shall be viewable from the roadway 3rd St.
Portable fire extinguishers - general
Corrective Action Required
05/04/2017

2012 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. ACTION REQUIRED: (verified at inspection) Provide one 2A-10BC fire extinguisher to be mounted on a normal path of travel close to an exit.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Change of Tenant $61.28 $61.28 Paid 09/29/2017
8331507-Sewer Connection Fee $300.00 $300.00 Paid 09/29/2017
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 07/03/2019
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/15/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/15/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Commercial Failed 10/3/2017 10/3/2017 at 1:00 AM 10/03/2017
Misc
Corrective Action Required
10/03/2017
Install cleanout. OK to backfill.
Underslab Plumbing Inspection - Commercial Passed 10/4/2017 at 8:35 AM 10/04/2017
Misc
Resolved
10/04/2017
Install cleanout. OK to backfill.
In-wall Inspection Not Ready 10/25/2017 10/25/2017 at 8:15 AM 10/25/2017
Misc
Corrective Action Required
10/25/2017
IBC 109.1, 109.5; IRC R109.3 INSPECTION ACCESS: PROPERTY LOCKED; INTERIOR NOT ACCESSIBLE. CALL FOR INSPECTION ON DAY WHEN JOBSITE IS ACCESSIBLE.
In-wall Inspection Not Ready 12/1/2017 at 4:15 PM 12/01/2017
Misc
Corrective Action Required
12/01/2017
NO PERMIT PRINTS ON SITE
Misc
Corrective Action Required
12/01/2017
NOT READY FOR INSPECTION. REPLACE BOTTOM PLATE WITH TREATED LUMBER. THEN REQUEST IN-WALL INSPECTION. CONTACT INSPECTOR FOR OTHER SPECIFIC ISSUES.
In-wall Inspection Failed 12/12/2017 1/5/2018 at 1:05 PM 01/05/2018
Misc
Corrective Action Required
01/05/2018
IPC 305.8 PROTECTION FROM PENETRATION OF PVC / ABS / PEX / COPPER PLUMBING PIPE LESS THAN 1-1/2" FROM FACE OF FRAMING TO RECEIVE SCREWED OR NAILED COVERING: PROTECT PIPE WITH MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES. SHIELD PLATES SHALL COVER THE AREA OF THE MEMBER WHERE THE PIPE PENETRATES. SHIELD PLATES SHALL EXTEND A MINIMUM OF 2" ABOVE BASE PLATES / TRACKS AND BELOW TOP PLATES / TRACKS. USE "BOCA" PLATES. CHECK ALL.
Misc
Corrective Action Required
01/05/2018
IBC 2308.9.10 OVER-BORED (>40% BEARING; >60% NON-BEARING) (5/8" MINIMUM TO EDGE) STUDS MUST BE DOUBLED OR REINFORCED WITH APPROVED STUD SHOE.
Misc
Corrective Action Required
01/05/2018
IRC R602.6 REINFORCING OF WALL TOP PLATE: WALL TOP PLATES CUT THROUGH OR NOTCHED/BORED > 50%. REINFORCE BOTH PIECES BOTH SIDES (IF INTERIOR WALL) WITH MIN 16 GA GALVANIZED METAL TIE. IF BOCA PLATES ARE REQUIRED AT SAME LOCATION APPLY REINFORCING STRAP TO TOP MEMBER AND BOCA PLATE TO BOTTOM MEMBER.
Above Ceiling Inspection Not Ready 12/12/2017 1/5/2018 01/05/2018
In-wall Inspection Failed 1/18/2018 at 1:05 PM 01/18/2018
Misc
Corrective Action Required
10/25/2017
BOCA PLATES AND STUD SHOES REQUIRED WHERE POINTED OUT
In-wall Inspection Passed 1/19/2018 1/19/2018 at 3:15 PM 01/19/2018
Misc
Resolved
01/19/2018
IPC 305.8 PROTECTION FROM PENETRATION OF PVC / ABS / PEX / COPPER PLUMBING PIPE LESS THAN 1-1/2" FROM FACE OF FRAMING TO RECEIVE SCREWED OR NAILED COVERING: PROTECT PIPE WITH MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES. SHIELD PLATES SHALL COVER THE AREA OF THE MEMBER WHERE THE PIPE PENETRATES. SHIELD PLATES SHALL EXTEND A MINIMUM OF 2" ABOVE BASE PLATES / TRACKS AND BELOW TOP PLATES / TRACKS. USE "BOCA" PLATES. CHECK ALL.
Misc
Resolved
01/19/2018
IBC 2308.9.10 OVER-BORED (>40% BEARING; >60% NON-BEARING) (5/8" MINIMUM TO EDGE) STUDS MUST BE DOUBLED OR REINFORCED WITH APPROVED STUD SHOE.
Misc
Resolved
01/19/2018
IRC R602.6 REINFORCING OF WALL TOP PLATE: WALL TOP PLATES CUT THROUGH OR NOTCHED/BORED > 50%. REINFORCE BOTH PIECES BOTH SIDES (IF INTERIOR WALL) WITH MIN 16 GA GALVANIZED METAL TIE. IF BOCA PLATES ARE REQUIRED AT SAME LOCATION APPLY REINFORCING STRAP TO TOP MEMBER AND BOCA PLATE TO BOTTOM MEMBER.
Above Ceiling Inspection Failed 4/16/2018 4/16/2018 at 1:10 PM 04/16/2018
Misc
Corrective Action Required
04/16/2018
RETURN AIR TO BE CLARIFIED WITH LS PLANS EXAMINER. DO NOT PLACE TILE PRIOR TO APPROVAL.
Misc
Corrective Action Required
04/16/2018
REMOVE ABANDONED ELECTRICAL BOX AT NE SPACE.
Misc
Corrective Action Required
04/16/2018
INSTALL SLACK WIRES ON 2x4 LIGHT FIXTURE AT SE SPACE.
Above Ceiling Inspection Passed 4/17/2018 at 1:15 PM 04/17/2018
Misc
Resolved
04/17/2018
RETURN AIR TO BE CLARIFIED WITH LS PLANS EXAMINER. DO NOT PLACE TILE PRIOR TO APPROVAL.
Misc
Resolved
04/17/2018
REMOVE ABANDONED ELECTRICAL BOX AT NE SPACE.
Misc
Resolved
04/17/2018
INSTALL SLACK WIRES ON 2x4 LIGHT FIXTURE AT SE SPACE.
Occupancy Inspection - Codes Commercial Failed 10/3/2018 10/3/2018 at 1:20 PM 10/03/2018
Misc
Corrective Action Required
10/03/2018
OBTAIN FIRE DEPARTMENT APPROVAL
Misc
Corrective Action Required
10/03/2018
COMPLETE FINISH ELECTRICAL WORK. - NEC 370-20; IRC E3806.5-6 SET-BACK OF ELECTRICAL RECEPTACLE / SWITCH BOXES: MUST BE FLUSH WITH COMBUSTIBLE WALL SURFACE; 1/4" MAXIMUM SET-BACK @ NON-COMBUSTIBLE SURFACES. CHECK ALL. - ENSURE RECEPTACLES ARE MOUNTED SOLID IN PLACE. USE YOKE SPACERS WHERE REQUIRED - ENSURE POLARITY IS CORRECT ON ALL RECEPTS - RECEPTS WITHIN 6' OF EDGE OF SINK MUST BE GFCI PROTECTED - FACE PLATES REQUIRED ON ALL RECEPTS AND SWITCHES
Misc
Corrective Action Required
10/03/2018
FINISH PLUMBING NOT READY FOR INSPECTION. COMPLETE INSTALLATION OF SINKS, ETC. CAP OFF ANY ABANDONED PIPING.
Misc
Corrective Action Required
10/03/2018
IPC 420.3: WATER CLOSET SEAT(S) MUST BE COMMERCIAL TYPE WITH OPEN FRONT
Misc
Corrective Action Required
10/03/2018
COMPLETE RESTROOM TO ADA STANDARDS PER DRAWINGS
Misc
Corrective Action Required
10/03/2018
TPR DISCHARGE PIPE NOT INSTALLED AT WATER HEATER
Misc
Corrective Action Required
10/03/2018
NEC 408.4: LABELING OF ELECTRICAL CIRCUIT POSITIONS AT PANEL(S): EACH BREAKER POSITION MUST BE LABELED. MUST BE LEGIBLE, SPECIFIC. IF PANEL SCHEDULE IS USED NUMBER POSITIONS ON PANEL FRONT PER SCHEDULE. NO DITTO MARKS OR CONTINUATION SYMBOLS EXCEPT @ MULTIPLE POLE BREAKERS. LABEL UNUSED BREAKERS "SPARE".
Misc
Corrective Action Required
10/03/2018
LS CODE OF ORDINANCES 17-309: DISPLAY OF "NO SMOKING" SIGN(S) REQUIRED AT PUBLIC ENTRY(IES). SHALL BE CONSPICOUS AT EACH PUBLIC POINT OF ENTRY.
Miscellaneous Inspection Passed 6/7/2019 at 7:15 AM 06/07/2019
Occupancy Inspection - Codes Commercial Not Ready 7/3/2019 7/3/2019 at 9:00 AM 07/03/2019
Misc
Corrective Action Required
10/03/2018
OBTAIN FIRE DEPARTMENT APPROVAL
Misc
Corrective Action Required
10/03/2018
COMPLETE FINISH ELECTRICAL WORK. - NEC 370-20; IRC E3806.5-6 SET-BACK OF ELECTRICAL RECEPTACLE / SWITCH BOXES: MUST BE FLUSH WITH COMBUSTIBLE WALL SURFACE; 1/4" MAXIMUM SET-BACK @ NON-COMBUSTIBLE SURFACES. CHECK ALL. - ENSURE RECEPTACLES ARE MOUNTED SOLID IN PLACE. USE YOKE SPACERS WHERE REQUIRED - ENSURE POLARITY IS CORRECT ON ALL RECEPTS - RECEPTS WITHIN 6' OF EDGE OF SINK MUST BE GFCI PROTECTED - FACE PLATES REQUIRED ON ALL RECEPTS AND SWITCHES
Misc
Corrective Action Required
10/03/2018
FINISH PLUMBING NOT READY FOR INSPECTION. COMPLETE INSTALLATION OF SINKS, ETC. CAP OFF ANY ABANDONED PIPING.
Misc
Corrective Action Required
10/03/2018
IPC 420.3: WATER CLOSET SEAT(S) MUST BE COMMERCIAL TYPE WITH OPEN FRONT
Misc
Corrective Action Required
10/03/2018
COMPLETE RESTROOM TO ADA STANDARDS PER DRAWINGS
Misc
Corrective Action Required
10/03/2018
TPR DISCHARGE PIPE NOT INSTALLED AT WATER HEATER
Misc
Corrective Action Required
10/03/2018
NEC 408.4: LABELING OF ELECTRICAL CIRCUIT POSITIONS AT PANEL(S): EACH BREAKER POSITION MUST BE LABELED. MUST BE LEGIBLE, SPECIFIC. IF PANEL SCHEDULE IS USED NUMBER POSITIONS ON PANEL FRONT PER SCHEDULE. NO DITTO MARKS OR CONTINUATION SYMBOLS EXCEPT @ MULTIPLE POLE BREAKERS. LABEL UNUSED BREAKERS "SPARE".
Misc
Corrective Action Required
10/03/2018
LS CODE OF ORDINANCES 17-309: DISPLAY OF "NO SMOKING" SIGN(S) REQUIRED AT PUBLIC ENTRY(IES). SHALL BE CONSPICOUS AT EACH PUBLIC POINT OF ENTRY.
Occupancy Inspection - Fire Not Ready 10/3/2018 07/03/2019
Occupancy Inspection - Fire Not Ready 7/3/2019 07/03/2019
Investigation Inspection Complete 12/11/2019 at 7:20 AM 12/11/2019
Investigation Inspection Complete 2/19/2020 02/19/2020
Occupancy Inspection - Codes Commercial Failed 2/20/2020 2/20/2020 at 1:50 PM 02/20/2020
Misc
Resolved
02/20/2020
OBTAIN FIRE DEPARTMENT APPROVAL
Misc
Corrective Action Required
12/04/2019
COMPLETE FINISH ELECTRICAL WORK. -MAKE ALL RECEPTACLES HOT FOR TEST - SOME WIRING AT RECEPTACLES NOT GROUNDED
Misc
Corrective Action Required
12/04/2019
INSTALL RESTROOM GRAB BARS PER IBC
Misc
Resolved
02/20/2020
IPC 420.3: WATER CLOSET SEAT(S) MUST BE COMMERCIAL TYPE WITH OPEN FRONT
Misc
Corrective Action Required
12/04/2019
INSTALL RESTROOM SIGN PER CODE
Misc
Corrective Action Required
12/04/2019
EXPANSION TANK NOT INSTALLED AT WATER HEATER
Misc
Corrective Action Required
12/04/2019
NEC 408.4: LABELING OF ELECTRICAL CIRCUIT POSITIONS AT PANEL(S): EACH BREAKER POSITION MUST BE LABELED. MUST BE LEGIBLE, SPECIFIC. IF PANEL SCHEDULE IS USED NUMBER POSITIONS ON PANEL FRONT PER SCHEDULE. NO DITTO MARKS OR CONTINUATION SYMBOLS EXCEPT @ MULTIPLE POLE BREAKERS. LABEL UNUSED BREAKERS "SPARE".
Misc
Resolved
02/20/2020
LS CODE OF ORDINANCES 17-309: DISPLAY OF "NO SMOKING" SIGN(S) REQUIRED AT PUBLIC ENTRY(IES). SHALL BE CONSPICOUS AT EACH PUBLIC POINT OF ENTRY.
Occupancy Inspection - Fire Passed 2/20/2020 02/20/2020
Occupancy Inspection - Codes Commercial Failed 2/27/2020 2/27/2020 at 3:55 PM 02/27/2020
Misc
Corrective Action Required
02/27/2020
RECEPTACLES AT POINT OF SERVICE: - ONE AT CENTER NOT SOLID TO BOX - ONE AT EAST END SHOWS FAULTY GROUND
Misc
Corrective Action Required
02/27/2020
INSTALL RESTROOM GRAB BARS PER IBC
Misc
Corrective Action Required
02/20/2020
INSTALL RESTROOM SIGN PER CODE
Misc
Resolved
02/27/2020
EXPANSION TANK NOT INSTALLED AT WATER HEATER
Misc
Corrective Action Required
02/20/2020
NEC 408.4: LABELING OF ELECTRICAL CIRCUIT POSITIONS AT PANEL(S): EACH BREAKER POSITION MUST BE LABELED. MUST BE LEGIBLE, SPECIFIC. IF PANEL SCHEDULE IS USED NUMBER POSITIONS ON PANEL FRONT PER SCHEDULE. NO DITTO MARKS OR CONTINUATION SYMBOLS EXCEPT @ MULTIPLE POLE BREAKERS. LABEL UNUSED BREAKERS "SPARE".
Occupancy Inspection - Codes Commercial Failed 5/27/2020 5/27/2020 05/27/2020
Misc
Corrective Action Required
02/27/2020
install address at front of building. -INSTALL RESTROOM SIGN PER CODE lower to correct height.
Misc
Resolved
05/27/2020
INSTALL RESTROOM GRAB BARS PER IBC
Misc
Resolved
05/27/2020
INSTALL RESTROOM SIGN PER CODE
Misc
Resolved
05/27/2020
NEC 408.4: LABELING OF ELECTRICAL CIRCUIT POSITIONS AT PANEL(S): EACH BREAKER POSITION MUST BE LABELED. MUST BE LEGIBLE, SPECIFIC. IF PANEL SCHEDULE IS USED NUMBER POSITIONS ON PANEL FRONT PER SCHEDULE. NO DITTO MARKS OR CONTINUATION SYMBOLS EXCEPT @ MULTIPLE POLE BREAKERS. LABEL UNUSED BREAKERS "SPARE".
Occupancy Inspection - Codes Commercial Failed 6/15/2020 6/15/2020 06/15/2020
Misc
Resolved
06/15/2020
install address at front of building. -INSTALL RESTROOM SIGN PER CODE lower to correct height.
Miscellaneous Correction
Corrective Action Required
06/15/2020
Pay all fees before occupancy
Occupancy Inspection - Codes Commercial Full C of O 6/16/2020 06/16/2020
Miscellaneous Correction
Resolved
06/16/2020
Pay all fees before occupancy
Documents & Images
Date Uploaded File Type Document Name
05/04/2017 Letter Fire Building Plan Review
05/05/2017 Letter Codes P/R Corrections Document
06/06/2017 Letter Codes P/R Corrections Document
07/03/2017 Letter Fire Building Plan Review
07/13/2017 Letter Codes Plan Review Conditions
09/28/2017 Letter Codes Plan Review Conditions
09/29/2017 Receipt Receipt for transaction: 2017-006570
09/29/2017 Letter Codes Building Permit
10/03/2017 Letter Inspection Summary
10/04/2017 Letter Inspection Summary
10/25/2017 Letter Inspection Summary
12/01/2017 Letter Inspection Summary
01/05/2018 Letter Inspection Summary
01/18/2018 Letter Inspection Summary
01/19/2018 Letter Inspection Summary
04/16/2018 Letter Inspection Summary
04/17/2018 Letter Inspection Summary
10/03/2018 Letter Inspection Summary
06/06/2019 Letter Codes 140 Day Letter
07/03/2019 Letter INSPECTION SUMMARY
07/03/2019 Receipt Receipt for transaction: 2019-004477
02/20/2020 Letter INSPECTION SUMMARY
02/27/2020 Letter INSPECTION SUMMARY
05/27/2020 Letter INSPECTION SUMMARY
06/15/2020 Receipt Receipt for transaction: 2020-003083
06/16/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home