PRCOM20161204


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20161204
Building Permit - Commercial
Final Completion
LBP III LLC
ALTERATION COMMERCIAL
STRUCTURAL STEEL MEZZANINE IN WAREHOUSE AREA *drawings are in plan review file
05/24/2016
06/08/2016
07/31/2017
Locations
Contacts
LBP III LLC, Address:3215 NE CARNEGIE DR STE 200  
SINGLE SOURCE SYSTEMS, Address:P O BOX 357, Phone:(816) 779-0924  
Reviews
Review Type Outcome Est. Completion Date Completed
Sprinkler Plan Review Released for Construction 06/06/2016 06/06/2017
Joe Dir
IFGC - Inspection, testing and maintenance - alarm and extinguishing systems 901.6
Corrective Action Required
06/06/2017

2012 IFC 901.6- Inspection, testing and maintenance. Fire detection, alarm and extinguishing systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Not required fire protection systems and equipment shall be inspected, tested and maintained or removed. ACTION REQUIRED:(verified at inspection) The existing fire sprinkler system riser shall be current with all required maintenance and servicing. A current serive tag shall be posted on the systems riser.
Licensed Contractors Approved 06/06/2016 06/08/2016
Development Center
Misc
Corrective Action Required
05/26/2016

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Provide company name of installing contractor.
Fire Plan Review Approved with Conditions 06/06/2016 05/31/2016
Joe Dir
Misc
Corrective Action Required
05/31/2016

Extend the fire sprinkler system coverage to be under the mezzanine.
Building Plan Review Approved with Conditions 06/06/2016 05/26/2016
Joe Frogge
Misc
Corrective Action Required
05/26/2016

2012 IBC 505.2 Mezzanines. A mezzanine or mezzanines in compliance with Section 505.2 shall be considered a portion of the story below. Such mezzanines shall not contribute to either the building area or number of stories as regulated by Section 503.1. The area of the mezzanine shall be included in determining the fire area. The clear height above and below the mezzanine floor construction shall be not less than 7 feet (2134 mm). Action required: Comment is for informational purposes. Headroom clearances to be verified during inspections.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Alteration to Commercial $30.00 $30.00 Paid 06/08/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Occupancy Inspection - Fire Failed 9/22/2016 09/22/2016
Occupancy Inspection - Codes Commercial Failed 9/22/2016 9/22/2016 09/22/2016
Misc
Corrective Action Required
09/22/2016
-FIRE DEPT. APPROVAL REQUIRED -PROVIDE CITY-APPROVED PLAN ON SITE -COLUMN SUPPORT PADS NOT INSTALLED. HAVE ENGINEER ADDRESS
Investigation Inspection Complete 4/28/2017 04/28/2017
Occupancy Inspection - Fire Passed 07/18/2017
Final Inspection - Commercial Failed 7/18/2017 7/18/2017 07/18/2017
Misc
Corrective Action Required
09/22/2016
-Column support pads not installed per Engineer's recommendation - enlargement and stiffening bars needed on 4, not 3 sides of each column.
Final Inspection - Commercial Passed 7/31/2017 07/31/2017
Misc
Resolved
07/31/2017
-Column support pads not installed per Engineer's recommendation - enlargement and stiffening bars needed on 4, not 3 sides of each column.
Occupancy Inspection - Codes Commercial Not Ready 11/14/2018
Misc
Corrective Action Required
07/31/2017
-FIRE DEPT. APPROVAL REQUIRED -PROVIDE CITY-APPROVED PLAN ON SITE -COLUMN SUPPORT PADS NOT INSTALLED. HAVE ENGINEER ADDRESS
Documents & Images
Date Uploaded File Type Document Name
05/31/2016 Letter Fire Building Plan Review
05/31/2016 Letter Codes P/R Corrections Document
06/08/2016 Letter Codes Plan Review Conditions
06/08/2016 Letter Codes Building Permit
06/08/2016 Receipt Receipt for transaction: 2016-003516
09/22/2016 Letter Inspection Summary
11/04/2016 Engineer letter
02/21/2017 Letter Codes 140 Day Letter
04/28/2017 Letter Codes 180 Day Letter
06/06/2017 Letter Fire (Sprinkler) Plan Review
07/18/2017 Letter Inspection Summary
07/31/2017 Letter Inspection Summary
08/03/2017 Engineer Report/Study DOC080317-014
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home