Planning Application Status

PL2023321




 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PL2023321
Chick-fil-A Drive-Thru Expansion
Commercial Final Development Plan
Commercial Final Development Plan
Approved
11/22/2023
Chick-fil-A, Inc
Expansion from the existing one lane drive-thru to two lanes
Locations
Contacts
Chick-fil-A, Inc, Address:5200 BUFFINGTON RD  
Chick-fil-A, Inc, Address:Attn: Michael Lewis, Phone:( ) -   
GBC Design, Inc, Address:Attn: Allan Wiley, Phone:(330) 836-0228  
Reviews
Review Type Outcome Est. Completion Date Completed
Planning Review No Comments 06/14/2024 06/12/2024
Hector Soto Jr.
Building Codes Review No Comments 01/25/2024 01/25/2024
Joe Frogge
Miscellaneous Correction
Resolved
01/25/2024

All structures greater than 6'-0" in height must have complete foundation and connection designs sealed/signed by professional engineer. Includes, but not limited to, monument sign, menu boards, height signage, etc.
Traffic Review No Comments 01/25/2024 01/24/2024
Erin Ralovo
Engineering Review Approved with Conditions 01/25/2024 01/19/2024
Susan Nelson, P.E.
DE C&O #01 Eng Plans – FDP/PDP
Corrective Action Required
01/19/2024

All required engineering plans and studies, including water lines, sanitary sewers, storm drainage, streets and erosion and sediment control shall be submitted along with the final development plan. All public infrastructure must be substantially complete, prior to the issuance of any certificates of occupancy.
DE C&O #03 Eng & Insp Fees
Corrective Action Required
01/19/2024

All Engineering Plan Review and Inspection Fees shall be paid prior to approval of the associated engineering plans and prior to the issuance of any site development permits or the start of construction (excluding land disturbance permit).
DE C&O #07 Easements
Corrective Action Required
01/19/2024

All permanent off-site easements, in a form acceptable to the City, shall be executed and recorded with the Jackson County Recorder of Deeds prior to the issuance of a Certificate of Substantial Completion or approval of the final plat. A certified copy shall be submitted to the City for verification.
DE C&O #11 Pavement Thickness
Corrective Action Required
01/19/2024

Private parking lots shall follow Article 8 of the Unified Development Ordinance for pavement thickness and base requirements.
DE Contact Field Eng. Inspector
Corrective Action Required
01/19/2024

Prior to the commencement of any construction activities, the Contractor shall contact Field Engineering Inspections at (816) 969-1200 to coordinate a preconstruction meeting / conference with the assigned Field Engineering Inspector.
DE Engineers Estimate
Corrective Action Required
01/19/2024

The Engineer’s Estimate of Probable Construction Costs has been accepted for this project, and the Engineering Plan Review and Inspection Fee (which is calculated as 3% of the total infrastructure cost plus a water test inspection fee(s)), and the water tap and meter setup fee have been included. These must be paid prior to the issuance of an infrastructure permit and/or the final processing of a building permit. $7,851.78
DE Future Repair Work
Corrective Action Required
01/19/2024

Please be aware that any future repair work to public infrastructure (e.g., water main repair, sanitary sewer repair, storm sewer repair, etc.) within public easements will not necessarily include the repair of pavement, curbing, landscaping, or other private improvements which are located within the easement.
Fire Review No Comments 01/25/2024 01/18/2024
Scott Ready
Planning Review No Comments 01/25/2024 01/18/2024
Scott Ready
Building Codes Review Corrections 12/20/2023 12/20/2023
Joe Frogge
Miscellaneous Correction
Corrective Action Required
12/20/2023

All structures greater than 6'-0" in height must have complete foundation and connection designs sealed/signed by professional engineer. Includes, but not limited to, monument sign, menu boards, height signage, etc.
Engineering Review Corrections 12/20/2023 12/20/2023
Susan Nelson, P.E.
Corrective Action Required
12/20/2023

Submit an Engineer's Estimate of Probable Construction Costs.
Corrective Action Required
12/20/2023

Submit the SWPPP and a copy of the MDNR Land Disturbance Permit.
Corrective Action Required
12/20/2023

Title Sheet - General Notes -Remove reference to Missouri Department of Transportation governing construction and change to the City of Lee's Summit. -Show location of all oil/gas wells, or indicate none are present, and cite the source.
Corrective Action Required
12/20/2023

Please provide a complete plan for the ADA-accessible ramps. Ensure all elevation callouts, running slope callouts, and cross-slope points for construction of ADA-accessible ramps and sidewalk. Also, include details through the stiped cross-walks to access the building.
Corrective Action Required
12/20/2023

The curb and gutter detail or pavement detail must show that the aggregate base and compaction of native subgrade extends a minimum of one (1) foot beyond the back of curb.
Corrective Action Required
12/20/2023

All asphalt materials shall conform to the KCMMB Asphalt Material Specification, current edition.
Corrective Action Required
12/20/2023

Only ornamental tree varieties are allowed within public easements. Please verify and revise accordingly.
Traffic Review Corrections 12/20/2023 12/20/2023
Susan Barry, P.E.
Corrective Action Required
12/20/2023

Minimum size of STOP sign is 30" per MUTCD. One of the STOP signs shown is too small. Also, a Do Not Enter cannot be placed on the back of the STOP sign if it obscures the shape of the STOP sign. Either increase the size of the STOP or move the DNE to a separate post. Minimum size for Do Not Enter is 30" x 30".
Informational
12/20/2023

Suggest using an actual ONE Way sign rather than a red/white very small sign. It would provide much more emphasis than what you have shown. R6-1, minimum size 36" x 12". What you have shown is more of a directional sign, rather than regulatory.
Planning Review No Comments 12/20/2023 12/20/2023
Hector Soto Jr.
Fire Review No Comments 12/20/2023 12/18/2023
Jim Eden
Fees
Paid Fees Amount Paid Owing Date Paid
Final Development Plan fee $725.00 $725.00 Paid 12/06/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Hearings
Title Location Date Time
Documents & Images
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New license, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home