Reviews
Review Type Outcome Est. Completion Date Completed
Planning Review No Comments 01/21/2022 01/21/2022
Hector Soto Jr.
Planning Review No Comments 11/17/2021 01/21/2022
Hector Soto Jr.
Corrective Action Required
11/19/2021

The inspection report provided called out several (5) correction items that are needed for the tower. Please provide an updated inspection report once the defences are addressed and corrected. Also, the tower image in the inspection report reflects a lattice tower. The tower at this location is a monopole, please clarify.
Corrective Action Required
11/19/2021

The proof of insurance doesn't meet the requirements stated below. Only $1,000,000 was listed for per occurrence for personal injury and no amount was listed for per occurrence for property damage. It was also noted the insurance form didn't reference this tower/tower site. Please clarify. PROOF OF INSURANCE. Provide proof of general liability insurance for claims from injury or death and property damage in an amount approved by the City, but not less than $2,000,000.00 per occurrence for personal injury and $2,000,000.00 per occurrence for property damage with the City listed and endorsed as an additional insured. The policy shall also include an endorsed waiver of subrogation against the City.
Building Codes Review Approved with Conditions 01/21/2022 01/13/2022
Joe Frogge
Miscellaneous Correction
Corrective Action Required
01/13/2022

A Building permit will be not be required.
Traffic Review No Comments 01/21/2022 01/13/2022
Scott Ready
Fire Review No Comments 01/21/2022 01/13/2022
Scott Ready
Engineering Review No Comments 01/21/2022 01/13/2022
Scott Ready
Engineering Review No Comments 11/17/2021 11/10/2021
Loic Nguinguiri, E.I.
Building Codes Review Approved with Conditions 11/17/2021 11/10/2021
Scott Ready
Miscellaneous Correction
Corrective Action Required
11/10/2021

A Building permit will be required for the electrical portion of this project.
Fire Review No Comments 11/17/2021 11/10/2021
Scott Ready
Traffic Review No Comments 11/17/2021 11/10/2021
Scott Ready
Fire Review No Comments 10/28/2021 10/28/2021
Scott Ready
Planning Review Corrections 10/28/2021 10/28/2021
Hector Soto Jr.
Corrective Action Required
10/28/2021

PROOF OF INSURANCE. Provide proof of general liability insurance for claims from injury or death and property damage in an amount approved by the City, but not less than $2,000,000.00 per occurrence for personal injury and $2,000,000.00 per occurrence for property damage with the City listed and endorsed as an additional insured. The policy shall also include an endorsed waiver of subrogation against the City.
Corrective Action Required
10/28/2021

INSPECTION REPORT. Provide a copy of an inspection report performed within the last three years that assesses the physical condition of the tower. This is not to be confused with the structural analysis report which has already been provided.
Engineering Review Corrections 10/28/2021 10/27/2021
Loic Nguinguiri, E.I.
Corrective Action Required
10/27/2021

Site location shown within the vicinity map is incorrect.
Corrective Action Required
10/27/2021

Please provide a structural analysis letter that confirm whether the new equipment addition meets ANSI/TIA-222-H design code requirements.
Traffic Review No Comments 10/28/2021 10/26/2021
Brad Cooley, P.E., RSPI
Building Codes Review Approved with Conditions 10/28/2021 10/22/2021
Joe Frogge
Miscellaneous Correction
Corrective Action Required
10/22/2021

A Building permit will be required for the electrical portion of this project.
Fees
Paid Fees Amount Paid Owing Date Paid
9110077-Final Development Plan fee $725.00 $725.00 Paid 10/08/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Hearings
Title Location Date Time
Documents & Images
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New license, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home