Review Type |
Outcome |
Est. Completion Date |
Completed |
Engineering Review
|
Approved with Conditions
|
01/31/2020
|
01/31/2020
|
|
Gene Williams, P.E.
|
|
Corrective Action Required
The off-site private sanitary easement has been reviewed and approved. Please have this document recorded and provided recording information on the plat submitted for signatures and recording.
|
|
|
GIS Review
|
Corrections
|
01/31/2020
|
01/27/2020
|
|
Kathy Kraemer
|
|
Corrective Action Required
Plat does not close.
Misclosure As X/Y: -1.998, 0.07
Misclosure As Direction/Distance: N 87-59-21 W, 2
Relative Error Ratio: 1:444
|
|
Corrective Action Required
The last call in the legal does not match the south line of the drawing.
|
|
|
Planning Review
|
No Comments
|
01/31/2020
|
01/27/2020
|
|
Hector Soto Jr.
|
|
|
Engineering Review
|
Corrections
|
01/16/2020
|
01/16/2020
|
|
Gene Williams, P.E.
|
|
Corrective Action Required
The floodplain note appears incorrect. Isn't this site within Zone X, areas outside the limits of any floodplain, including the 0.2% chance floodplain?
|
|
Corrective Action Required
The Drainage Note must be revised. No Master Drainage Plan exists for this site. As such, the note should be revised to read "...The lot owner shall not change or obstruct the drainage flow lines or paths on the lots, unless specific application is made and approved by the City Engineer."
|
|
Corrective Action Required
Please see Planning comments concerning signture blocks. The City Engineer title block and name is incorrect.
|
|
Corrective Action Required
A public water main appears to exist along the west edge of the property. Please verify the location of this line, and ensure that a ten (10) foot general utility easement along the western edge of the property is sufficient. If the water main is located further eastward, this minimum ten (10) foot general utility easement may need to be widened.
|
|
Corrective Action Required
A minimum of ten (10) foot general utility easement should be dedicated along the western edge of the lot. Please see previous comment concerning the water main, and ensure this width is sufficient. If the water main is located further west, and not on the property line, then additional width may be required.
|
|
Corrective Action Required
An off-site private sanitary sewer easement is required prior to plat approval. This private easement is required, in order to provide sanitary sewer service to Lot 5A-1. Prior to execution of this document, please submit a courtesy review copy of the language, along with an 8.5 inch by 11 inch exhibit showing the limits of the private easement. Following a short review of the language contained in the private sanitary sewer easement, as well as the required 8.5 inch by 11 inch exhibit showing the limits of the private sanitary sewer easement, the applicant shall be required to execute and record the private easement with the Jackson County Recorders Office. A document number must be submitted for this private easement prior to formal approval of this plat.
|
|
|
GIS Review
|
Corrections
|
01/16/2020
|
01/08/2020
|
|
Kathy Kraemer
|
|
Corrective Action Required
A review was not completed as an electronic copy of the plat was not submitted. Provide and electronic copy at resubmittal.
|
|
|
Planning Review
|
Corrections
|
01/16/2020
|
01/03/2020
|
|
Hector Soto Jr.
|
|
Corrective Action Required
PROPERTY LINE INFORMATION. The labeled bearings for all four property lines differs from those labeled on the previous plat for the property. Include the bearings for the respective property lines from the previous plat and label them (P) for platted.
|
|
Corrective Action Required
BUILDING SETBACK LINES. Remove the building setbacks shown along the north, south and east property lines. Our practice is to only show and dedicate building lines along the right-of-way, in this case only along the west side of the subject property.
|
|
Corrective Action Required
PROPERTY OWNER/NOTARY SIGNATURE. Update references to the year 2019 with 2020.
|
|
Corrective Action Required
CITY SIGNATURE BLOCK.
- Replace the end of the approval paragraph at the top of the signature block with the following language to read, "...pursuant to Chapter 33, the Unified Development Ordinance, of the City of Lee's Summit Code of Ordinances."
- Revise George Binger's name to read as George M. Binger III, PE.
- Replace Josh Johnson's name with Ryan A. Elam, PE. Also, change the title for Mr. Elam to Director of Development Services.
|
|
Corrective Action Required
OIL/GAS WELLS. Include a note on the plat regarding the presence of any active, inactive or capped oil and/or gas wells on the subject property. Cite the source of information used to make this determination. MDNR has an online database of all permitted oil and gas wells in the state.
|
|
Corrective Action Required
STREET NAMES. Add the "SE" quadrant prefix to the names of Missouri Hwy 291 and Melody Lane.
|
|
Corrective Action Required
DEDICATION PARAGRAPHS.
- Remove the streets dedication paragraph since no new right-of-way is being dedicated as part of this plat.
- Should the City's Development Engineering staff require the dedication of any utility easement as part of this plat (see department comments contained within this letter), include the standard easement dedication paragraph found under the sampled language found in UDO Section 7.140.
|
|
|