Planning Application Status

PL2018115




 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PL2018115
Napa Valley 4th Plat - Sanitary Sewer
Engineering Plan Review
Engineering Plan Review
Complete
07/13/2018
MAR INVESTMENTS INC
Locations
Address
1840 SW SAGE CANYON RD, LEES SUMMIT, MO 64082

Address
1836 SW SAGE CANYON RD, LEES SUMMIT, MO 64082

Address
1828 SW SAGE CANYON RD, LEES SUMMIT, MO 64082

Address
1824 SW SAGE CANYON RD, LEES SUMMIT, MO 64082

Address
1816 SW SAGE CANYON RD, LEES SUMMIT, MO 64082

Address
1812 SW SAGE CANYON RD, LEES SUMMIT, MO 64082

Address
1808 SW SAGE CANYON RD, LEES SUMMIT, MO 64082

Address
1841 SW SAGE CANYON RD, LEES SUMMIT, MO 64082

Address
1837 SW SAGE CANYON RD, LEES SUMMIT, MO 64082

Address
1833 SW SAGE CANYON RD, LEES SUMMIT, MO 64082

Address
1829 SW SAGE CANYON RD, LEES SUMMIT, MO 64082

Address
1825 SW SAGE CANYON RD, LEES SUMMIT, MO 64082

Address
1821 SW SAGE CANYON RD, LEES SUMMIT, MO 64082

Address
1817 SW SAGE CANYON RD, LEES SUMMIT, MO 64082

Address
1813 SW SAGE CANYON RD, LEES SUMMIT, MO 64082

Address
1809 SW SAGE CANYON RD, LEES SUMMIT, MO 64082

Address
1805 SW SAGE CANYON RD, LEES SUMMIT, MO 64082

Address
1801 SW SAGE CANYON RD, LEES SUMMIT, MO 64082

Property
69720061500000000

Property
69720061600000000

Property
69720061700000000

Property
69720061800000000

Property
69720061900000000

Property
69720062000000000

Property
69720062100000000

Property
69720062200000000

Property
69720053500000000

Property
69720053400000000

Property
69720053300000000

Property
69720053200000000

Property
69720053100000000

Property
69720053000000000

Property
69720052900000000

Property
69720052800000000

Property
69720052700000000

Property
69720052600000000

Property
69720052500000000

Address
1800 SW SAGE CANYON RD, LEES SUMMIT, MO 64082

Contacts
MAR INVESTMENTS INC, Address:PO BOX 847  
ENGINEERING SOLUTIONS, Address:50 SE 30TH ST, Phone:(816) 623-9888  
LITTMAN LEVI AND KNIPP LACY, Address:1800 SW SAGE CANYON RD  
MOORE TIMOTHY & THERESA, Address:1808 SW SAGE CANYON RD  
BARBARA R CHESNEY REVOCABLE TRUST DATED 10-13-2011, Address:1812 SW SAGE CANYON RD  
BURNAP RICHARD L & TERESA A, Address:1816 SW SAGE CANYON RD  
ARMSTRONG CHRISTOPHER THOMAS & AMANDA MAE, Address:1824 SW SAGE CANYON RD  
SULLIVAN HENSON E, Address:1828 SW SAGE CANYON RD  
KEVIN HIGDON CONSTRUCTION, Address:PO BOX 847, Phone:(816) 524-9797  
KEVIN HIGDON CONSTRUCTION LLC, Address:PO BOX 847, Phone:(816) 524-9797  
HUBBARD KATHRYN ELAINE, Address:1801 SW SAGE CANYON RD  
STEWART CHRISTIAN, Address:1805 SW SAGE CANYON RD  
BLAKE CHRISTOPHER J, Address:1809 SW SAGE CANYON RD  
WILSON DERECK EUGENE, Address:1813 SW SAGE CANYON RD  
HARDING BURTON, Address:1817 SW SAGE CANYON RD  
ALLEN SHEA L & LACEY, Address:1825 SW SAGE CANYON RD  
VIGNOLA JAY & ELAINE A, Address:1829 SW SAGE CANYON RD  
WILSON MITCH AARON & ELIZABETH ANN, Address:1833 SW SAGE CANYON RD  
ARNOLD AARON & KATRINA, Address:1837 SW SAGE CANYON RD  
THORNE REVOCABLE TRUST LIVING TRUST DATED 08-18-2022, Address:1841 SW SAGE CANYON RD  
Reviews
Review Type Outcome Est. Completion Date Completed
Engineering Review No Comments 10/02/2018 10/01/2018
Gene Williams, P.E.
Traffic Review No Comments 10/02/2018 10/01/2018
Michael Park
Engineering Review Corrections 09/10/2018 09/10/2018
Gene Williams, P.E.
Corrective Action Required
09/10/2018

Please refer to the previous applicant letter dated Aug. 2, 2018. Comment #8 requested a trenching and backfill detail, but none was provided in the Details section of the plans.
Engineering Review Corrections 08/03/2018 08/02/2018
Gene Williams, P.E.
Corrective Action Required
08/02/2018

The title block on sheet C.400 is misleading. Please change to reflect what is shown on the cover sheet (i.e., Sanitary Sewer Construction Plans).
Corrective Action Required
08/02/2018

Sheet C.401: Please call-out the existing City manhole numbers. J-1 is 60-191. D-2 is 60-271.
Corrective Action Required
08/02/2018

Geometry of the Sanitary Sewer: Extraneous manholes are provided with no clear purpose. It appears the manhole at station 3+65 could be placed near station 3+05, and lined up to eliminate manhole A-1. It appears the minimum distance could be maintained between the building line and the storm sewer to make this work. Finally, B-1 could be eliminated, and B-2 placed closer to the back of curb, and still maintain the required spacing for the build line.
Corrective Action Required
08/02/2018

Sheet C.402: Will the existing manhole at station 0+00 be adjusted to grade? As shown, it appears to be 6 inches above ground, with a potential conflict with the sidewalk.
Corrective Action Required
08/02/2018

All Sheets: The notes specify trench checks, with no indication of where the detail is located or which detail should be followed. Please provide a detail of the trench check, and provide sufficient notes on the plans referencing the sheet number and standard detail designation.
Corrective Action Required
08/02/2018

Sheet C.402: Manhole A-1 is shown too low?
Corrective Action Required
08/02/2018

Sheet C.402: It is vague and unclear what is occurrinig at existing manhole J-1. The profile view says "remove and replace manhole", with what appears to be a stub. What is being proposed at this location? Please be specific.
Corrective Action Required
08/02/2018

Detail Sheet: It appears the manhole frame and lid detail was missing, along with trench check detail, and trenching and backfill detail.
Hearings

There are no hearings for this planning application.

Documents & Images
Date Uploaded File Type Document Name
08/02/2018 Letter DE-Comment Letter (Engineering Plans)
08/31/2018 Plans NAPA VALLEY 4TH PLAT
09/10/2018 Letter DE-Comment Letter (Engineering Plans)
09/25/2018 Plans Sanitary Complete Set
01/10/2019 Engineers Estimate CV Fee Worksheet -NapaValley4thSAN
10/03/2019 Letter DE-Engineering Plans Approval Letter
08/06/2020 Approved Plans Napa Valley 4th Plat Sanitary Complete Set electronically approved 8.6.20
01/20/2021 Plans SANITARY ASBUILTS
11/17/2021 Accepted Record Drawings Napa Valley 4th Sanitary AsBuilts Accepted RD
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New license, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home