Planning Application Status

PL2018104




 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PL2018104
Oakview Storage - Public Sanitary Sewer Extension
Engineering Plan Review
Engineering Plan Review
Approved
06/25/2018
OAK VIEW LEES SUMMIT LLC
Locations
Contacts
OAK VIEW LEES SUMMIT LLC, Address:201 HAWKS RIDGE TRL  
OAKVIEW CAPITAL PARTNERS, LLC, Address:201 HAWKS RIDGE TRAIL, Phone:(214) 460-8442  
SCHLAGEL & ASSOCIATES, Address:14920 W 107TH ST, Phone:(913) 492-5158  
Reviews
Review Type Outcome Est. Completion Date Completed
Engineering Review No Comments 08/27/2018 10/05/2018
Mike Weisenborn
Engineering Review Corrections 07/17/2018 07/17/2018
Gene Williams, P.E.
Corrective Action Required
07/17/2018

Sheet C2.0: A minimum drop of 0.5 feet is required at the existing manhole, due to the magnitude of the angle of deflection.
Corrective Action Required
07/17/2018

Sheet C2.0: Please number the existing manhole. It is City Manhole #23-053.
Corrective Action Required
07/17/2018

Sheet C2.0: The depth of cover between A1 and A2 exceeds the City's maximum of fifteen (15.0) feet. We measured 16.5 feet.
Corrective Action Required
07/17/2018

Sheet C2.0: The depth of cover between A3 and A4 exceeds the City's maximum of fifteen (15.0) feet. We measured 15.5 feet.
Corrective Action Required
07/17/2018

Detail Sheet(s) were missing the following required items: 1) manhole frame and lids, with appropriate lettering (i.e., SEWER), 2) trenching and backfill detail in accordance with the Design and Construction Manual, and 3) trench check detail.
Corrective Action Required
07/17/2018

Detail Sheet(s) appear to show items that will not be installed as part of this project. Please remove them. This includes the concrete encasement detail, the drop manhole detail, and the shallow manhole detail.
Hearings

There are no hearings for this planning application.

Documents & Images
Date Uploaded File Type Document Name
06/25/2018 Plans 2018.05.14 17-135 SAN FULL SET REV0
07/17/2018 Letter DE-Comment Letter (Engineering Plans)
09/14/2018 Letter DE-Engineering Plans Approval Letter
11/05/2020 Plans 2020_11_04 17-135 SAN AS-BUILT
02/02/2021 Plans 2021_02_02 17-135 SAN C1_0 - AS-BUILT REV3
11/09/2022 Accepted Record Drawings Oakview Storage Sanitary AsBuilts Accepted RD
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New license, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home