PL2017050
Hawthorn Ridge 1st Plat sanitary plans
Engineering Plan Review
Engineering Plan Review
Approved
03/07/2017
CMH PARKS INC
Locations
Contacts
OLSSON , Address:7301 W 133RD ST STE 200, Phone:(913) 381-1170  
CMH PARKS INC, Address:5000 CLAYTON RD  
Reviews
Review Type Outcome Est. Completion Date Completed
Engineering Review No Comments 04/28/2017 04/28/2017
Gene Williams, P.E.
Engineering Review Corrections 03/27/2017 03/27/2017
Gene Williams, P.E.
Corrective Action Required
03/27/2017

Sheet C203: It appears the sanitary sewer to serve the property to the east was omitted from the plans. Please see the approved Preliminary Development Plan for placement of the this required sanitary sewer line to the plat boundary. The Preliminary Development Plan showed this line extending to the east along Arbor Falls Dr. to the east property line.
Corrective Action Required
03/27/2017

Sheet C203: We are recommending a complete re-design of the alignment of the sanitary sewer in order to eliminate unnecessary manholes. It appears there are too many manholes which are not necessary, and it appears these manholes were placed to comply with the "five feet from the back of curb rule". It is also not necessary to place the sanitary sewer within an easement, but rather, the right of way is acceptable. There may be certain situations where the "five feet from back of curb rule" may be waived, where curved streets make this rule cumbersome. With that in mind, please ensure all sanitary sewer wye connections are outside of any paved area, or at least at the back of curb. Again, this would only apply on a case-by-case basis where curved streets preclude strict adherence to the "five feet from back of curb rule".
Corrective Action Required
03/27/2017

Sheet C203: Suggested list of manholes which we believe are unneccessary: 1) MH 2-1, 2) MH 1-6, 3) MH 1-4, 4) MH 4-1, and 5) MH 5-1. There may be different alignnments that would work better, so please keep in mind this list might change based on the re-alignment.
Corrective Action Required
03/27/2017

Sheet C204: Is there any way to bring the short section of sanitary sewer Line 1 into compliance with the fifteen foot rule near station 13+45? Why is it necessary to have a drop manhole at this location?
Corrective Action Required
03/27/2017

All Sheets: Please go through the plan sheets and eliminate the strikeovers. There appear to be several throughout the plan set.
Corrective Action Required
03/27/2017

Sheet C210: The future line beyond manhole MH 6-2 is shown at minimum slope. Please change the downstream pipe slopes/manhole depths to accommodate a higher-than-minimum future slope in this line.
Corrective Action Required
03/27/2017

Sheet C210: By designing for a 0.65% slope from MH 6-1 to MH 1-2, it would appear that approximately 1 foot could be gained from the excessively-deep sanitary sewer at MH 1-2. It appears the 42" HDPE storm line near MH 1-2 could be raised slightly to accommodate this change.
Corrective Action Required
03/27/2017

Please be aware that the off-site sanitary sewer plans are being reviewed separately, and easements for the off-site portion of the sanitary sewer have not yet been obtained.
Hearings

There are no hearings for this planning application.

Documents & Images
Date Uploaded File Type Document Name
03/27/2017 Letter PW-Comment Letter (Engineering Plans)
05/15/2017 Plans C201 - COVER SHEET
05/15/2017 Plans C202 - GENERAL NOTES
05/15/2017 Plans C203 - GENERAL LAYOUT
05/15/2017 Plans C204 - PLAN AND PROFILE1
05/15/2017 Plans C205 - PLAN AND PROFILE2
05/15/2017 Plans C206 - PLAN AND PROFILE3
05/15/2017 Plans C207 - PLAN AND PROFILE4
05/15/2017 Plans C208 - PLAN AND PROFILE5
05/15/2017 Plans C209 - PLAN AND PROFILE6
05/15/2017 Plans C210 - PLAN AND PROFILE7
05/15/2017 Plans C211 - PLAN AND PROFILE8
05/15/2017 Plans C212 - DETAIL SHEET1
05/15/2017 Plans C213 - DETAIL SHEET2
05/15/2017 Plans C214 - DETAIL SHEET3
10/30/2017 Activity Document ArborwalkNorth1SANMDNRConcurrence
10/30/2017 Activity Document MDNR Concurrence Letter SAN
10/30/2017 Activity Document MDNR Concurrence Letter SAN2
10/30/2017 Activity Document MDNRConcurrenceSAN2
10/30/2017 Activity Document Fee WorksheetOnSiteSAN
10/30/2017 Activity Document SanitarySewerStudyArborwalkNorthBody
10/30/2017 Activity Document SanitarySewerStudyArborwalkNorthAppendices
01/17/2018 Plans C208 SANITARY SEWER PLAN & PROFILE
01/17/2018 Plans C209 SANITARY SEWER PLAN & PROFILE
01/17/2018 Plans C210 SANITARY SEWER PLAN & PROFILE
01/17/2018 Plans C211 SANITARY SEWER PLAN & PROFILE
01/17/2018 Plans C212 DETAIL SHEET
01/17/2018 Plans C213 DETAIL SHEET (2)
01/17/2018 Plans C214 SANITARY SEWER TABLES
01/17/2018 Plans C201 COVER SHEET
01/17/2018 Plans C202 GENERAL NOTES
01/17/2018 Plans C203 GENERAL LAYOUT
01/17/2018 Plans C204 SANITARY SEWER PLAN & PROFILE
01/17/2018 Plans C205 SANITARY SEWER PLAN & PROFILE
01/17/2018 Plans C206 SANITARY SEWER PLAN & PROFILE
01/17/2018 Plans C207 SANITARY SEWER PLAN & PROFILE
01/17/2018 Plans C201 COVER SHEET
01/17/2018 Plans C202 GENERAL NOTES
01/17/2018 Plans C203 GENERAL LAYOUT
01/17/2018 Plans C204 SANITARY SEWER PLAN & PROFILE
01/17/2018 Plans C205 SANITARY SEWER PLAN & PROFILE
01/17/2018 Plans C206 SANITARY SEWER PLAN & PROFILE
01/17/2018 Plans C207 SANITARY SEWER PLAN & PROFILE
01/17/2018 Plans C208 SANITARY SEWER PLAN & PROFILE
01/17/2018 Plans C209 SANITARY SEWER PLAN & PROFILE
01/17/2018 Plans C210 SANITARY SEWER PLAN & PROFILE
01/17/2018 Plans C211 SANITARY SEWER PLAN & PROFILE
01/17/2018 Plans C212 DETAIL SHEET
01/17/2018 Plans C213 DETAIL SHEET (2)
01/17/2018 Plans C214 SANITARY SEWER TABLES
05/16/2018 Letter DE-Engineering Plans Approval Letter
06/29/2018 Plans C203 GENERAL LAYOUT
06/29/2018 Plans C208 SANITARY SEWER PLAN & PROFILE
06/29/2018 Plans C214 SANITARY SEWER TABLES
06/29/2018 Plans C201 COVER SHEET
06/29/2018 Plans C202 GENERAL NOTES
03/10/2023 Plans 2019-03-04_Sanitary_Asbuilts
03/10/2023 Accepted Record Drawings Hawthorn Ridge 1st Sanitary AsBuilts Accepted RD
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New license, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home