Review Type |
Outcome |
Est. Completion Date |
Completed |
Engineering Review
|
Approved with Conditions
|
12/06/2016
|
12/06/2016
|
|
Christina Stanton
|
|
DE C&O #01 Eng Plans – FDP/PDP
Corrective Action Required
All required engineering plans and studies, including water lines, sanitary sewers, storm drainage, streets and erosion and sediment control shall be submitted along with the final development plan. All public infrastructure must be substantially complete, prior to the issuance of any certificates of occupancy.
|
|
DE C&O #03 Eng & Insp Fees
Corrective Action Required
All Engineering Plan Review and Inspection Fees shall be paid prior to approval of the engineering plans and prior to the issuance of any infrastructure permits or the start of construction (excluding land disturbance permit).
|
|
DE C&O #06 Land Disturbance
Corrective Action Required
A Land Disturbance Permit shall be obtained from the Public Works Department if ground breaking will take place prior to the issuance of an infrastructure permit or prior to the approval of the Final Development Plan / Engineering Plans.
|
|
DE C&O #11 Pavement Thickness
Corrective Action Required
Private pavement sections shall either follow Article 12 of the UDO or Table LS-2 or LS-3 of the Design & Construction Manual for pavement thickness and base requirements.
|
|
DE C&O #12 Cut & Fill
Corrective Action Required
Any cut and / or fill operations, which cause public infrastructure to exceed the maximum / minimum depths of cover shall be mitigated by relocating the infrastructure vertically and / or horizontally to meet the specifications contained within the City’s Design and Construction Manual.
|
|
|
Planning Review
|
No Comments
|
12/06/2016
|
12/06/2016
|
|
Christina Stanton
|
|
|
Traffic Review
|
No Comments
|
12/06/2016
|
12/06/2016
|
|
Michael Park
|
|
|
Fire Review
|
Approved with Conditions
|
12/06/2016
|
11/25/2016
|
|
Jim Eden
|
|
Code Statement
Corrective Action Required
All issues pertaining to life safety and property protection from the hazards of fire, explosion or dangerous conditions in new and existing buildings, structures and premises, and to the safety to fire fighters and emergency responders during emergency operations, shall be in accordance with the 2012 International Fire Code.
|
|
|
Engineering Review
|
Corrections
|
11/04/2016
|
11/04/2016
|
|
Gene Williams, P.E.
|
|
Corrective Action Required
The domestic water service is shown in a commercial driveway entrance. Please move the water service and meter outside of the driveway.
|
|
Corrective Action Required
If interior fire hydrant(s) are needed, then these should be shown on a private fire line, with a backflow vault installed near the property line outside of any public easement, and on the private side.
|
|
|
Traffic Review
|
No Comments
|
11/04/2016
|
11/03/2016
|
|
Michael Park
|
|
|
Fire Review
|
Corrections
|
11/04/2016
|
10/31/2016
|
|
Jim Eden
|
|
Code Statement
Corrective Action Required
All issues pertaining to life safety and property protection from the hazards of fire, explosion or dangerous conditions in new and existing buildings, structures and premises, and to the safety to fire fighters and emergency responders during emergency operations, shall be in accordance with the 2012 International Fire Code (IFC).
For information only. The quantity of stored new and used lubricants shall comply with the IFC Chapter 50 and 57.
|
|
Hydrants
Corrective Action Required
IFC 507.5.1- Where a portion of the facility or building hereafter constructed or moved into or within the jurisdiction is more than 300 feet from a hydrant on a fire apparatus access road, as measured by an approved route around the exterior of the facility or building, on-site fire hydrants and mains shall be provided where required by the fire code official.
Action required: Show the location of accessible hydrants.
Action required: Show the location of an accessible hydrant.
|
|
Misc.
Corrective Action Required
903.2.9.1 Repair garages.
An automatic sprinkler system shall be provided throughout all buildings used as repair garages in accordance with Section 406.8 of the International Building Code, as shown:
1. Buildings having two or more stories above grade plane, including basements, with a fire area containing a repair garage exceeding 5,000 square feet .
2. Buildings no more than one story above grade plane, with a fire area containing a repair garage exceeding 5,000 square feet.
3. Buildings with repair garages servicing vehicles parked in basements.
4. A Group S-1 fire area used for the repair of commercial trucks or buses where the fire area exceeds 5,000 square feet (464 m2).
Action required:
The building is required to have an automatic sprinkler system.
|
|
FDC
Corrective Action Required
IFC 903.3.7- Fire department connections. The location of fire department connections shall be approved by the fire code official. Connections shall be a 4 inch Storz type fitting and located within 100 feet of a fire hydrant, or as approved by the code official.
Action required: Show the location of the FDC and provide a hyran.t
|
|
|
Planning Review
|
Corrections
|
11/04/2016
|
10/26/2016
|
|
Christina Stanton
|
|
Corrective Action Required
Lighting. All outdoor lighting shall utilize full cut-off lenses per Section 7.220.B of the UDO. In addtion, provide a photometric plan to show lighting location, height and uniformity ratio information as required per Sections 7.230 and 7.250.F of the UDO.
|
|
Corrective Action Required
Signage. Call out the signage information for those signs located above the service bays. In addition, provide the materials and colors proposed for the monument sign.
|
|
Corrective Action Required
Provide the percentage of metal panels proposed for the elevations.
|
|
Corrective Action Required
Parking Lot Screening. Provide parking lot screening per Section 14.120 of the UDO.
|
|
Corrective Action Required
Four-Sided Architecture. Vertical elements shall be incorporated into the east elevation to break up the expanse of wall.
|
|
|