Summary


PRSUBD20231141
Public Infrastructure
Final Acceptance
INDEPENDENCE SAFETY STORAGE NORTH II LLC
DEVELOPMENT COMPLETE
Public water main along Town Centre Blvd
03/20/2023
06/28/2023
02/10/2025
Locations
Contacts
INDEPENDENCE SAFETY STORAGE NORTH II LLC, Address:1120 A NW EAGLE RIDGE BLVD  
FOGEL-ANDERSON CONSTRUCTION CO, Address:1212 E 8TH ST, Phone:(816) 842-6914  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 03/20/2023 06/01/2023
Mike Weisenborn
Fees
Paid Fees Amount Paid Owing Date Paid
91100C9-Water Insp Fee $2,947.24 $2,947.24 Paid 06/27/2023
9110072-Water Test Fee $400.00 $400.00 Paid 06/27/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Partial 7/24/2023 07/25/2023
Misc
Informational
07/17/2023
7-17-23 NS Site visited and no erosion control issues 7-25-23 NS Site visited and no erosion control issues
Erosion Control Inspection Passed 8/4/2023 08/04/2023
Misc
Informational
07/25/2023
7-17-23 NS Site visited and no erosion control issues 7-25-23 NS Site visited and no erosion control issues
Grading/Excavation/Fill Inspection Passed 3/29/2024 03/29/2024
Misc
Informational
03/29/2024
3-29-24 NS Site Visited and it appears that grading is complete.
Water Line - Construction Inspection Passed 6/24/2024 06/25/2024
Misc
Informational
06/25/2024
10-12-23 NS Site visited crew is working 10-13-23 NS Site visited crew is working on water 10-17-23 NS Site visited crew is working 10-19-23 NS Site visited crew is not working 10-24-23 NS Site visited crew has poured kickers 10-25-23 NS Site visited crew is working 11-1-23 NS Site visited crew is working on back flow 11-2-23 NS Site visited crew is working 11-3-23 NS Site visited crew is not working 11-6-23 NS Site visited crew is not working 11-7-23 NS Site visited crew is working on water and installing fire hydrants 11-8-23 NS Site visited crew is working 11-10-23 NS Site visited crew is working 11-14-23 NS Site visited crew is not working 11-15- NS Site visited crew is not working 11-16-23 NS Site visited crew is working 11-17-23 NS Site visited crew is working 11-21-23 NS Site visited crew is working on water line 11-28-23 NS Site visited crew is digging for the water line 11-29-23 NS Site visited crew is laying pipe 12-12-23 NS Site visited crew is not working 12-19-23 NS Site visited crew is not working today 12-20-23 NS Site visited crew is not working 12-28-23 NS Site visited crew is working 1-3-24 NS Site visited crew is not working 1-18-24 NS Site visited crew is working on the last part of the line 1-19-24 NS Site visited crew is working on back flow and pouring kickers 1-30-24 NS Site visited doing a hydro test. passed 3-21-24 - both water test passed 4-2-24 PS No inspections for development today 6-25-24 NS Site visited and it appears everything has passed
Water Line - Hydrostatic Test Passed 11/13/2024 11/13/2024
Documents & Images
Date Uploaded File Type Document Name
05/25/2023 Activity Document PL2023064 Town Center Logistics Fee Worksheet
06/08/2023 Approved Plans Town Centre Logistics Water Approved 060823
06/27/2023 Receipt Receipt for transaction: 2023-004864
06/28/2023 Letter DE-Permit
03/29/2024 Letter INSPECTION SUMMARY
03/29/2024 Letter INSPECTION SUMMARY
03/29/2024 Letter INSPECTION SUMMARY
06/25/2024 Letter INSPECTION SUMMARY
06/25/2024 Letter INSPECTION SUMMARY
06/26/2024 Letter INSPECTION SUMMARY
06/27/2024 Letter DE-Certificate of Substantial Completion Single Lot
06/27/2024 Letter DE-Punch List
07/15/2024 Security Document MAINTENANCE BOND
08/15/2024 Plans As-Built Plans - TC22L4 - CP Exc - 8-14-2024
11/13/2024 Letter INSPECTION SUMMARY
12/20/2024 Plans Water As-builts 241220
02/10/2025 Affidavit
02/10/2025 Letter DE-Certificate of Final Acceptance (Commercial)
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: