Permit Application Status

PRSGN20252808


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRSGN20252808
Sign Permit
In Plan Review
OLDHAM INVESTORS LLC
SIGN
The scope of work is outlined in the attached drawings. The scope of work includes the following: • A1: Monument sign, D/F illuminated, 70 square feet • A2/A3: Tenant panels for multi-tenant signs, quantity 4 (2 for each sign, A2 & A3) • B: Wall Sign, LED-illuminated channel letters, 37.71 square feet • C: Wall sign, LED-illuminated channel letters, 37.71 square feet • D: Wall sign, Illuminated logo cabinet, 36 square feet • E: Wall sign, LED-illuminated channel letters, 37.71 square feet • F: Wall sign, welcome wall sign dimensional stamp, 6.25 square feet • DOT regulatory traffic signs • H1/H2: Static digital drive-thru menu boards, Qty. 2 • CB-1: Drive-thru clearance bar, Qty. 2 • FP: 25’ Flag pole • Window graphics/address numbers/interior vestibule door graphics/interior playground graphics
07/02/2025
Locations
Contacts
Clayton Signs, Inc., Address:5198 North Lake Drive  
Kaylin Altman, Address:5198 North Lake Drive, Phone:(404) 361-3800 Ext:402  
OLDHAM INVESTORS LLC, Address:7200 W 132ND ST STE 150  
Reviews
Review Type Outcome Est. Completion Date Completed
Sign Permit Review Rejected 07/07/2025 07/08/2025
Ian Trefren
Miscellaneous Correction
Corrective Action Required
07/08/2025

Proposed signage exceeds the count maximum of the PMIX district for attached wall signage on single-tenant commercial buildings (proposed - 5; maximum - 3). Signs 'D' and 'F' are considered attached wall signs.
Miscellaneous Correction
Corrective Action Required
07/08/2025

Confirm that incidental signage adhered to the glass elements (e.g. push/pull decals) will be located on the interior of the pane, such that it will not be exposed to the elements.
Misc
Corrective Action Required
07/08/2025

The process for seeking a modification to the sign count maximum is via a Sign Application, which is reviewed by Planning Commission as part of a consent agenda item.
Inspections

There are no inspections for this permit application.

Documents & Images
Date Uploaded File Type Document Name
07/02/2025 CFA - Lee's Summit_ MO (US 50 & SR 291) Signage A2(1)
07/08/2025 Permit DS P/R Corrections Document
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home