Summary
PRRES20255259
Building Permit - Residential
Issued
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - UNFINISHED BASEMENT STOP WORK ORDER generated on 01/14/2026 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 01/16/2026 12:00 AM by username 'Wes Bears'.
12/01/2025
12/08/2025
06/03/2026
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
COULTER@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $2,398.00 $2,398.00 Paid 12/08/2025
Right of Way Permit Fee $85.00 $85.00 Paid 12/08/2025
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 12/08/2025
Water Tap Fee $4,080.00 $4,080.00 Paid 12/08/2025
Water Meter Fee $791.53 $791.53 Paid 12/08/2025
Valuation Fee New Single Family $1,750.13 $1,750.13 Paid 12/08/2025
Parks Impact Fee Residential Zone 2 $1,000.00 $1,000.00 Paid 12/08/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Driveway Inspection Pending
Plot Plan Inspection Pending
Erosion Control Inspection Residential Pending
Occupancy Inspection - Codes Residential Pending
Sewer Service Inspection - R Passed 1/14/2026 1/14/2026 01/14/2026
Footing Inspection - Residential Failed - Stop Work 1/14/2026 1/14/2026 01/14/2026
Misc
Corrective Action Required
01/14/2026
STOP WORK ISSUED NO FOOTING INSPECTION PERFORMED 3RD PARTY FOOTING INSPECTION REPORTS SHALL BE UPLOADED WITHIN 48 HRS OF COMPLETION
Footing Inspection - Residential Passed 1/16/2026 01/16/2026
Misc
Corrective Action Required
01/14/2026
STOP WORK ISSUED NO FOOTING INSPECTION PERFORMED 3RD PARTY FOOTING INSPECTION REPORTS SHALL BE UPLOADED WITHIN 48 HRS OF COMPLETION
Water Service Inspection - R Passed 1/20/2026 1/20/2026 01/20/2026
Underslab Plumbing Inspection - Residential Passed 1/20/2026 1/20/2026 01/20/2026
All Rough Inspection - Residential Failed 2/10/2026 2/10/2026 02/10/2026
Misc
Corrective Action Required
02/10/2026
PORTAL FRAME AND PORCH FRAMING ONLY SHEETING AROUND FRONT PORCH OK PORTAL AND PORCH FRAMING OK
Misc
Informational
02/17/2026
=the nail pattern on the sheething and lap was inspected by Wes Bears
Gas Service Inspection - Residential Failed 3/3/2026 3/3/2026 03/03/2026
Misc
Corrective Action Required
03/03/2026
Pressure okay Provide approved listed ufer ground connections
Electrical Service Inspection Failed 3/3/2026 3/3/2026 03/03/2026
Misc
Corrective Action Required
03/03/2026
Provide approved listed ufer connection
All Rough Inspection - Residential Failed 3/3/2026 3/3/2026 03/03/2026
Misc
Resolved
03/03/2026
PORTAL FRAME AND PORCH FRAMING ONLY SHEETING AROUND FRONT PORCH OK PORTAL AND PORCH FRAMING OK
Misc
Corrective Action Required
03/03/2026
Maintain gravel entry. No further inspections until erosion control is in compliance -seal penetrations in hvac chase in kitchen -missing nails in LIB strap in flex room -missing lateral bracing throughout -solid block sheathing breaks at 2nd floor below top plate throughout -fireblock top dead space primary bath (1/2” osb not approved fire blocking material) -strap top plates where lapped less than 24” SE primary bedroom -missing stud at hall closet 2nd floor -provide additional bracing for island above in basement per plans -provide listed approved ufer connections installed correctly
All Rough Inspection - Residential Passed 3/5/2026 3/5/2026 03/05/2026
Misc
Resolved
03/05/2026
Maintain gravel entry. No further inspections until erosion control is in compliance -seal penetrations in hvac chase in kitchen -missing nails in LIB strap in flex room -missing lateral bracing throughout -solid block sheathing breaks at 2nd floor below top plate throughout -fireblock top dead space primary bath (1/2” osb not approved fire blocking material) -strap top plates where lapped less than 24” SE primary bedroom -missing stud at hall closet 2nd floor -provide additional bracing for island above in basement per plans -provide listed approved ufer connections installed correctly
Gas Service Inspection - Residential Passed 3/5/2026 3/5/2026 03/05/2026
Misc
Corrective Action Required
03/03/2026
Pressure okay Provide approved listed ufer ground connections
Electrical Service Inspection Passed 3/5/2026 3/5/2026 03/05/2026
Misc
Corrective Action Required
03/03/2026
Provide approved listed ufer connection
Documents & Images
Date Uploaded File Type Document Name
12/01/2025 BY #2060 - PERMIT APP
12/02/2025 Approved Plans APPROVED TRUSS PACKAGE
12/02/2025 Approved Plans APPROVED TRUSS LAYOUT
12/02/2025 Plot Plan APPROVED PLOT PLAN
12/05/2025 Permit Codes Residential Plan Review
12/08/2025 Approved Plans APPROVED PLANS
12/08/2025 Permit Codes Residential Plan Review
12/08/2025 Permit DS Building Permit
12/08/2025 Receipt Receipt for transaction:2025-008857
01/14/2026 Letter INSPECTION SUMMARY
01/14/2026 Letter Stop Work Order
01/15/2026 2060 Bailey Farms-FTNG-Stamped
01/16/2026 Letter INSPECTION SUMMARY
01/20/2026 Letter INSPECTION SUMMARY
01/20/2026 Letter INSPECTION SUMMARY
02/10/2026 Letter INSPECTION SUMMARY
03/03/2026 Letter INSPECTION SUMMARY
03/03/2026 Letter INSPECTION SUMMARY
03/03/2026 Letter INSPECTION SUMMARY
03/05/2026 Letter INSPECTION SUMMARY
03/05/2026 Letter INSPECTION SUMMARY
03/05/2026 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home