Permit Application Status

PRRES20250680


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20250680
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. COVERED DECK.
03/04/2025
03/13/2025
09/02/2025
10/24/2025
Locations
Contacts
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
Joseph Matthew Schartz, Address:PO Box 942, Phone:(816) 524-3855  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
TEAGUE ELECTRIC CONSTRUCTION LLC, Address:12425 W 92ND ST, Phone:(913) 529-4600  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
MARIA@SABHOMES.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $3,973.00 $3,973.00 Paid 03/13/2025
Water Meter Fee $748.03 $748.03 Paid 03/13/2025
Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 03/13/2025
Right of Way Permit Fee $85.00 $85.00 Paid 03/13/2025
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 03/13/2025
Valuation Fee New Single Family $1,620.83 $1,620.83 Paid 03/13/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 4/2/2025 04/02/2025
Misc
Corrective Action Required
04/02/2025
Erosion control not in compliance (repair downed silt fence No address posted
Underslab Plumbing Inspection - Residential Failed 4/2/2025 4/2/2025 04/02/2025
Misc
Corrective Action Required
04/02/2025
Inspection denied Erosion control not in compliance (repair downed silt fence No address posted
Erosion Control Inspection Residential Failed 4/4/2025 4/4/2025 04/04/2025
Misc
Corrective Action Required
04/04/2025
Repair downed silt fence around lot
Underslab Plumbing Inspection - Residential Passed 4/3/2025 4/4/2025 04/04/2025
Misc
Resolved
04/04/2025
Inspection denied Erosion control not in compliance (repair downed silt fence No address posted
Sewer Service Inspection - R Passed 4/8/2025 4/8/2025 04/08/2025
Water Service Inspection - R Partial 4/8/2025 4/8/2025 04/08/2025
Misc
Informational
04/08/2025
Pex from foundation roughly 15’
Water Service Inspection - R Passed 4/9/2025 4/9/2025 04/09/2025
Misc
Resolved
04/09/2025
Pex from foundation roughly 15’
Footing Inspection - Residential Passed 4/11/2025 4/14/2025 04/14/2025
Misc
Resolved
04/14/2025
Erosion control not in compliance (repair downed silt fence No address posted
All Rough Inspection - Residential Partial 5/13/2025 5/13/2025 05/13/2025
Misc
Informational
05/13/2025
Portal frame ok Back porch ok to cover
Electrical Service Inspection Passed 6/9/2025 6/9/2025 06/09/2025
Gas Service Inspection - Residential Passed 6/9/2025 6/9/2025 06/09/2025
All Rough Inspection - Residential Failed 6/9/2025 6/9/2025 06/09/2025
Misc
Informational
05/13/2025
Portal frame ok Back porch ok to cover
Misc
Corrective Action Required
06/09/2025
2226 SW Heartland ct - strap at top plate garage entry bath - Protect wire within 6’ of attic access - Joist hangers on ceiling joists to lvl of bedroom 3 - 2x12 in bedroom 3 should continue to lvl instead of ending on non load bearing wall - Fire blocking at right side of fireplace - Reattach vent fan exhaust in master toilet - Address purlin on non load bearing wall office hall wall - Sister over notched studs in basement - Add blocking in front cantilever in basement -
Erosion Control Inspection Residential Partial 6/11/2025 06/11/2025
All Rough Inspection - Residential Passed 6/11/2025 6/11/2025 06/11/2025
Misc
Informational
06/09/2025
Portal frame ok Back porch ok to cover
Misc
Resolved
06/11/2025
2226 SW Heartland ct
Driveway Inspection Partial 7/10/2025 07/10/2025
Misc
Informational
07/10/2025
07/10/25 Jamie S, DW is compacted and formed. Approved to pour.
Driveway Inspection Passed 7/17/2025 7/17/2025 07/17/2025
Misc
Informational
07/10/2025
07/10/25 Jamie S, DW is compacted and formed. Approved to pour. 07/17/25 Jamie S, DW slopes are compliant with city standards.
Erosion Control Inspection Residential Passed 9/16/2025 9/16/2025 09/16/2025
Misc
Resolved
04/14/2025
Repair downed silt fence around lot
Occupancy Inspection - Codes Residential Failed 9/16/2025 9/16/2025 09/16/2025
Misc
Corrective Action Required
09/16/2025
-will check plot plan at reinspect or approval from city -complete landscape at front entry -splash blocks and sump pump discharge to extend 36” from foundation -provide secondary locking device at rear slider -missing handrail at deck stairs -(2) 1/2” through bolts at each deck post to beam connection -remove all smoke & smoke/co dust covers for inspection -missing afci protection for circuits 12,14 -provide lockout for all hard wired appliance circuits -secure A/c whip within 12” of disconnect -provide tamper proof caps at A/c -outlets on side and back of home not working
Occupancy Inspection - Codes Residential Failed 9/16/2025 9/16/2025 09/16/2025
Misc
Corrective Action Required
09/16/2025
-Provide handrail in garage -will check plot plan at reinspect or approval from city -complete landscape at front entry -splash blocks and sump pump discharge to extend 36” from foundation -provide secondary locking device at rear slider -missing handrail at deck stairs -(2) 1/2” through bolts at each deck post to beam connection -remove all smoke & smoke/co dust covers for inspection -missing afci protection for circuits 12,14 -provide lockout for all hard wired appliance circuits -Provide a grounding clamp listed for connection to rebar. Contact of dis-similar materials (copper&iron) not allowed -secure A/c whip within 12” of disconnect -provide tamper proof caps at A/c -outlets on side and back of home not working
Plot Plan Inspection Passed 9/17/2025 09/17/2025
Occupancy Inspection - Codes Residential Full C of O 10/24/2025 10/24/2025
Misc
Resolved
10/24/2025
Documents & Images
Date Uploaded File Type Document Name
03/04/2025 HFR207 - Air Combustion Calcs
03/04/2025 HFR207 - Excise Tax Application
03/04/2025 HFR207 - Permit Application
03/06/2025 Permit Codes Residential Plan Review
03/13/2025 Plot Plan APPROVED PLOT PLAN
03/13/2025 Approved Plans APPROVED PLANS
03/13/2025 Permit Codes Residential Plan Review
03/13/2025 Permit DS Building Permit
03/13/2025 Receipt Receipt for transaction:2025-001548
03/18/2025 3RD Party Insp Report M L Crose 2226 SW Heartland Ct LSMO 3rd Party Footing Inspection Report Page 1 3-18-25
03/18/2025 3RD Party Insp Report M L Crose 2226 SW Heartland Ct LSMO 3rd Party Footing Inspection Report Page 2 3-18-25
04/02/2025 Letter INSPECTION SUMMARY
04/02/2025 Letter INSPECTION SUMMARY
04/04/2025 Letter INSPECTION SUMMARY
04/04/2025 Letter INSPECTION SUMMARY
04/08/2025 Letter INSPECTION SUMMARY
04/08/2025 Letter INSPECTION SUMMARY
04/09/2025 Letter INSPECTION SUMMARY
04/14/2025 Letter INSPECTION SUMMARY
04/14/2025 Letter INSPECTION SUMMARY
04/22/2025 2025_04_18_2226 SW Heartland Ct_Dpier_Report_Sealed
05/13/2025 Letter INSPECTION SUMMARY
06/09/2025 Letter INSPECTION SUMMARY
06/09/2025 Letter INSPECTION SUMMARY
06/09/2025 Letter INSPECTION SUMMARY
06/11/2025 Letter INSPECTION SUMMARY
06/11/2025 Letter INSPECTION SUMMARY
07/10/2025 Letter INSPECTION SUMMARY
07/17/2025 Letter INSPECTION SUMMARY
09/16/2025 Letter INSPECTION SUMMARY
09/16/2025 Letter INSPECTION SUMMARY
09/16/2025 Letter INSPECTION SUMMARY
09/16/2025 Plot Plan APPROVED AS BUILT PLOT PLAN
09/17/2025 Letter INSPECTION SUMMARY
10/24/2025 Letter Field Certificate of Occupancy
10/24/2025 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home