Summary
PRRES20245956
Building Permit - Residential
Issued
DJ23 INVESTMENTS LLC
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. WALKOUT BASEMENT. UNCOVERED DECK. ROOF TRUSSES - DEFERRED.
11/13/2024
11/22/2024
05/14/2025
Locations
Contacts
Avital Homes, LLC, Address:7500 W 151st Street, #23100, Phone:(816) 914-7128  
DJ23 INVESTMENTS LLC, Address:7200 W 132ND ST  
Doug Jenson, Address:11010 Nora Dodge Dr, Phone:(816) 266-0685  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
CARUTHERS ELECTRICAL LLC, Address:30905 E TRUMAN RD, Phone:(816) 508-9050  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
DOUG@APGKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,973.00 $3,973.00 Paid 11/22/2024
8350015-Water Meter Fee $748.03 $748.03 Paid 11/22/2024
8331507-Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 11/22/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 11/22/2024
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 11/22/2024
9110078-Valuation Fee New Single Family $1,578.34 $1,578.34 Paid 11/22/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 03/17/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Plot Plan Inspection Pending
Occupancy Inspection - Codes Residential Pending
Erosion Control Inspection Residential Pending
Miscellaneous Correction
Informational
02/11/2025
Full erosion control measures are in place at the time of inspection
All Rough Inspection - Residential Pending
Misc
Informational
04/04/2025
- Plans need to be revised to state "not intended for garage" or labeled " future craft area" If at a basement finish permit is obtained at a later date and the area is sectioned offit will need to be protected as a garage. Ok to insulate
Sidewalk Inspection Pending
Misc
Informational
04/18/2025
4-18-25 Dustin A, sw is not ready on this lot
Driveway Inspection Pending
Misc
Informational
04/23/2025
4-18-25 Dustin A, dw is formed and compacted . Approved to pour 4-23-25 Dustin A, Dw is poured to city specs, cannot pass until forms are poured.
Erosion Control Inspection Residential Partial 1/3/2025 01/03/2025
Miscellaneous Correction
Informational
01/03/2025
Erosion control is in place at the time of inspection
Footing Inspection - Residential Failed 1/3/2025 01/03/2025
Miscellaneous Correction
Corrective Action Required
01/03/2025
Footing passed by a third party Footing inspection failed due to no address posted on the property
Sewer Service Inspection - R Passed 1/23/2025 1/23/2025 01/23/2025
Water Service Inspection - R Passed 1/24/2025 1/24/2025 01/24/2025
Footing Inspection - Residential Passed 1/30/2025 01/30/2025
Miscellaneous Correction
Resolved
01/30/2025
Footing passed by a third party Footing inspection failed due to no address posted on the property
Erosion Control Inspection Residential Failed 1/30/2025 01/30/2025
Miscellaneous Correction
Resolved
01/30/2025
Erosion control is in place at the time of inspection
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
01/30/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - Post street address - Gravel filter needs to be extended to reach the foundation - Install erosion control measures around stock pile of soil in the lot next door
Underslab Plumbing Inspection - Residential Failed 1/30/2025 1/30/2025 01/30/2025
Miscellaneous Correction
Corrective Action Required
01/30/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - Post street address - Gravel filter needs to be extended to reach the foundation - Install erosion control measures around stock pile of soil in the lot next door Reschedule underslab inspection after the above corrections have been made
Erosion Control Inspection Residential Partial 2/4/2025 02/04/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
02/04/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - Post street address - Gravel filter needs to be extended to reach the foundation - Install erosion control measures around stock pile of soil in the lot next door
Miscellaneous Correction
Informational
02/04/2025
Full erosion control measures are in place at the time of inspection
Underslab Plumbing Inspection - Residential Passed 2/5/2025 02/05/2025
Miscellaneous Correction
Resolved
02/05/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - Post street address - Gravel filter needs to be extended to reach the foundation - Install erosion control measures around stock pile of soil in the lot next door Reschedule underslab inspection after the above corrections have been made
Erosion Control Inspection Residential Partial 2/11/2025 2/11/2025 02/11/2025
Miscellaneous Correction
Informational
02/04/2025
Full erosion control measures are in place at the time of inspection
All Rough Inspection - Residential Not Ready 2/11/2025 2/11/2025 02/11/2025
Miscellaneous Correction
Corrective Action Required
02/11/2025
Garage framing has not been started, so a garage PFH inspection could not be conducted Not ready for inspection Please walk your property before scheduling inspections
All Rough Inspection - Residential Failed 2/26/2025 2/26/2025 02/26/2025
Miscellaneous Correction
Resolved
02/26/2025
Garage framing has not been started, so a garage PFH inspection could not be conducted Not ready for inspection Please walk your property before scheduling inspections
Miscellaneous Correction
Corrective Action Required
02/26/2025
Exterioior garage PFH sheating is not nailed to the upper most top plate acording to plans page S530
All Rough Inspection - Residential Failed 3/4/2025 3/4/2025 03/04/2025
Miscellaneous Correction
Resolved
03/04/2025
Exterioior garage PFH sheating is not nailed to the upper most top plate acording to plans page S530
Miscellaneous Correction
Informational
03/04/2025
Exterior garage PFH sheathing passed and is okay to cover This is a partial pass only
All Rough Inspection - Residential Failed 3/28/2025 3/28/2025 03/28/2025
Miscellaneous Correction
Resolved
03/28/2025
Exterior garage PFH sheathing passed and is okay to cover This is a partial pass only
Misc
Corrective Action Required
03/28/2025
1916 sw hightown - Nail off girder trusses through out - Provide anchor bolts at breaks within 12 inches of end. in garage - Minimum of 3 studs at exterior corners in single bay garage - Nail off exterior corner studs throughout - Bedroom 3 fire block return air space penetration - Complete nailing of stud shoes in master bedroom exterior load bearing wall - Missing hanger master closet - Anchor all steel columns in basement - Provide anchor bolts with in 12” of plate breaks in basement - Address over notched double joists at basement near sump - Basement anchor bolts to be in middle third of plate - Update plans and submit for review the change of garage door in basement instead of 5 foot sliding door, load calls. Etc
Electrical Service Inspection Failed 3/28/2025 3/28/2025 03/28/2025
Misc
Corrective Action Required
03/28/2025
Incomplete
Gas Service Inspection - Residential Passed 3/28/2025 3/28/2025 03/28/2025
All Rough Inspection - Residential Failed 4/2/2025 4/2/2025 04/02/2025
Misc
Informational
04/02/2025
- Still have no recieved info on if any fire protection is requred for garage door in basement. Ok to insulate
Electrical Service Inspection Failed 4/3/2025 4/3/2025 04/03/2025
Misc
Resolved
04/03/2025
Incomplete
Misc
Corrective Action Required
04/03/2025
- REMOVE GREEN BONDINING SCREW FROM SUB PANEL IN BASEMENT.
All Rough Inspection - Residential Failed 4/4/2025 04/04/2025
Misc
Informational
04/02/2025
- Plans need to be revised to state "not intended for garage" or labeled " future craft area" If at a basement finish permit is obtained at a later date and the area is sectioned offit will need to be protected as a garage. Ok to insulate
Electrical Service Inspection Passed 4/4/2025 4/4/2025 04/04/2025
Misc
Resolved
04/04/2025
Driveway Inspection Partial 4/18/2025 4/18/2025 04/18/2025
Misc
Informational
04/18/2025
4-18-25 Dustin A, dw is formed and compacted . Approved to pour
Sidewalk Inspection Partial 4/18/2025 4/18/2025 04/18/2025
Misc
Informational
04/18/2025
4-18-25 Dustin A, sw is not ready on this lot
Driveway Inspection Partial 4/23/2025 4/23/2025 04/23/2025
Misc
Informational
04/18/2025
4-18-25 Dustin A, dw is formed and compacted . Approved to pour 4-23-25 Dustin A, Dw is poured to city specs, cannot pass until forms are poured.
Documents & Images
Date Uploaded File Type Document Name
11/13/2024 Avalon - Contemporary Layout GL
11/13/2024 RS 114 Permit Application Signed
11/13/2024 RS 114 Tax application
11/15/2024 Permit Codes Residential Plan Review
11/15/2024 Approved Plans APPROVED PLANS
11/19/2024 Plot Plan APPROVED PLOT PLAN
11/19/2024 Permit Codes Residential Plan Review
11/22/2024 Permit DS Building Permit
11/22/2024 Receipt Receipt for transaction:2024-009118
12/23/2024 Approved Plans 12-23-24 APPROVED PLANS
01/03/2025 114 Reserve at Stoney Creek - FTG-signed-stamped
01/03/2025 Letter INSPECTION SUMMARY
01/03/2025 Letter INSPECTION SUMMARY
01/23/2025 Letter INSPECTION SUMMARY
01/24/2025 Letter INSPECTION SUMMARY
01/30/2025 Letter INSPECTION SUMMARY
01/30/2025 Letter INSPECTION SUMMARY
01/30/2025 Letter INSPECTION SUMMARY
02/04/2025 Letter INSPECTION SUMMARY
02/05/2025 Letter INSPECTION SUMMARY
02/11/2025 Letter INSPECTION SUMMARY
02/11/2025 Letter INSPECTION SUMMARY
02/26/2025 Letter INSPECTION SUMMARY
03/04/2025 Letter INSPECTION SUMMARY
03/17/2025 Receipt Receipt for transaction:2025-001612
03/26/2025 114 RS - GT Letter - 250319
03/28/2025 Approved Plans APPROVED TRUSS PACKAGE
03/28/2025 Letter INSPECTION SUMMARY
03/28/2025 Letter INSPECTION SUMMARY
03/28/2025 Letter INSPECTION SUMMARY
03/28/2025 Approved Plans APPROVED TRUSS LAYOUT
04/02/2025 114 Reserve at Stoney Creek- Drill floor joist field issue- stamped
04/02/2025 Letter INSPECTION SUMMARY
04/03/2025 Letter INSPECTION SUMMARY
04/04/2025 Letter INSPECTION SUMMARY
04/04/2025 Letter INSPECTION SUMMARY
04/10/2025 Approved Plans APPROVED REVISED PLANS
04/18/2025 Letter INSPECTION SUMMARY
04/18/2025 Letter INSPECTION SUMMARY
04/23/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.