PRRES20244472


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20244472
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. COVERED PATIO. STOP WORK ORDER generated on 04/23/2025 12:00 AM by username 'Dustin Agcopra'. STOP WORK ORDER removed on 04/24/2025 12:00 AM by username 'Jamie Simerly'.
08/23/2024
09/05/2024
02/26/2025
05/30/2025
Locations
Contacts
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
Kevin higdon, Address:Po box 847  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INTERSTATE CONSTRUCTION SERVICES, Address:1450 SE BROADWAY DR, Phone:(816) 524-9797  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
DOUG@HIGDONBUILDERS.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,973.00 $3,973.00 Paid 09/05/2024
8350015-Water Meter Fee $748.03 $748.03 Paid 09/05/2024
8331507-Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 09/05/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 09/05/2024
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 09/05/2024
9110078-Valuation Fee New Single Family $2,093.57 $2,093.57 Paid 09/05/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 05/27/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Partial 9/25/2024 09/25/2024
Miscellaneous Correction
Informational
09/25/2024
Full erosion control measures are in place and must maintained until CofO
Footing Inspection - Residential Passed 9/25/2024 9/25/2024 09/25/2024
Miscellaneous Correction
Corrective Action Required
09/25/2024
Footing passed. Exterior piers were not part of this footing inspection
Erosion Control Inspection Residential Partial 10/11/2024 10/11/2024
Miscellaneous Correction
Informational
09/25/2024
Full erosion control measures are in place and must maintained until CofO
Underslab Plumbing Inspection - Residential Passed 10/11/2024 10/11/2024 10/11/2024
Erosion Control Inspection Residential Partial 10/29/2024 10/29/2024
Miscellaneous Correction
Informational
10/11/2024
Full erosion control measures are in place and must maintained until CofO
Water Service Inspection - R Partial 10/29/2024 10/29/2024
Miscellaneous Correction
Informational
10/29/2024
PEX has been run 10 feet out from the foundation and is okay to cover This is a partial pass only
Sewer Service Inspection - R Passed 10/29/2024 10/29/2024 10/29/2024
Water Service Inspection - R Passed 10/30/2024 10/30/2024 10/30/2024
Miscellaneous Correction
Resolved
10/30/2024
PEX has been run 10 feet out from the foundation and is okay to cover This is a partial pass only
Erosion Control Inspection Residential Failed 11/20/2024 11/20/2024
Miscellaneous Correction
Resolved
11/20/2024
Full erosion control measures are in place and must maintained until CofO
Miscellaneous Correction
Corrective Action Required
11/20/2024
-Some silt fence at the front of the property has been damaged and needs to be repaired or replaced -Full erosion control measures must be in place and properly maintained until CofO
All Rough Inspection - Residential Failed 11/20/2024 11/20/2024 11/20/2024
Miscellaneous Correction
Corrective Action Required
11/20/2024
Builder asked for garage PFH inspection only -Exterior sheathing hold down straps are not installed and nailed off -Interior hold down straps were either covered or not installed -Interior PFH anchor bolts were not fully installed Repair of replace damaged silt fence for proper erosion control before scheduling any more inspection (address erosion control inspection)
Erosion Control Inspection Residential Failed 12/18/2024 12/18/2024
Miscellaneous Correction
Corrective Action Required
11/20/2024
-Some silt fence at the front of the property has been damaged and needs to be repaired or replaced -Full erosion control measures must be in place and properly maintained until CofO
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
12/18/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Repair or replace damaged silt fence Full erosion control measures must be in place and properly maintained until CofO
All Rough Inspection - Residential Failed 12/18/2024 12/18/2024 12/18/2024
Miscellaneous Correction
Corrective Action Required
11/20/2024
Builder asked for garage PFH inspection only -Exterior sheathing hold down straps are not installed and nailed off -Interior hold down straps were either covered or not installed -Interior PFH anchor bolts were not fully installed Repair of replace damaged silt fence for proper erosion control before scheduling any more inspection (address erosion control inspection)
Miscellaneous Correction
Corrective Action Required
12/18/2024
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. See erosion control inspection on 11/20/24 and all rough inspection dated 11/20/24
Piers/Caissons Inspection - Residential Passed 12/18/2024 12/18/2024 12/18/2024
All Rough Inspection - Residential Failed 12/20/2024 12/20/2024 12/20/2024
Miscellaneous Correction
Resolved
12/20/2024
Builder asked for garage PFH inspection only -Exterior sheathing hold down straps are not installed and nailed off -Interior hold down straps were either covered or not installed -Interior PFH anchor bolts were not fully installed Repair of replace damaged silt fence for proper erosion control before scheduling any more inspection (address erosion control inspection)
Miscellaneous Correction
Resolved
12/20/2024
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. See erosion control inspection on 11/20/24 and all rough inspection dated 11/20/24
Miscellaneous Correction
Informational
12/20/2024
Exterior garage PFH sheeting passed and is okay to cover This is a partial pass only
All Rough Inspection - Residential Not Ready 1/21/2025 1/21/2025 01/21/2025
Miscellaneous Correction
Informational
12/20/2024
Exterior garage PFH sheeting passed and is okay to cover This is a partial pass only
Misc
Corrective Action Required
01/21/2025
NOT READY, INSPECTION DENIDE FIRE BLOCKING NOT COMPLETE STILL WORKING ON THIS HOUSE Shawn Hoffman 01/21/2025 9:48 AM
All Rough Inspection - Residential Failed 1/23/2025 1/23/2025 01/23/2025
Miscellaneous Correction
Resolved
01/23/2025
Exterior garage PFH sheeting passed and is okay to cover This is a partial pass only
Misc
Resolved
01/23/2025
NOT READY, INSPECTION DENIDE FIRE BLOCKING NOT COMPLETE STILL WORKING ON THIS HOUSE Shawn Hoffman 01/21/2025 9:48 AM
Miscellaneous Correction
Corrective Action Required
01/23/2025
Second anchor bolt is missing at west wall of garage PFH Nail corner of garage double overhead door west side to code Sister kind stud at bottom plate that has been over notched at garage east side PFH wall Nail corner of garage double overhead door east side to code Strap top plate at entry to garage corner since they do not overlap Fire block top and bottom of HVAC chase in garage Vertically support garage chase in garage drop ceiling every 4 feet on center Install rafter collar ties above 3rd car garage Vertically support ridge beam to hip beams above 3rd car garage Garage anchor bolt in 3rd car garage bottom plate is a 1/2 inch diameter instead of 5/8 foot inch Floor joist above pantry has been notched at the top for water waste line Floor joist above kitchen has been notched at the top for 3 inch waste line Gas line to fireplace is not installed Fire block top of chase in basement bathroom Attach bottom of steel post to Ibeam at stairs going to the basement Tie main ridge beam together with a rafter tie Install electrical nail guard for electrical in master bathroom to master toilet wall Install Boca plate in master linen closet at bottom plate for 4 inch mechanical vent Strap top plate in master bathroom to master closet for not being overlapping Air duct is not installed in the utility room
Gas Service Inspection - Residential Passed 1/23/2025 01/23/2025
Electrical Service Inspection Passed 1/23/2025 01/23/2025
All Rough Inspection - Residential Passed 2/5/2025 2/5/2025 02/05/2025
Miscellaneous Correction
Resolved
02/05/2025
Second anchor bolt is missing at west wall of garage PFH Nail corner of garage double overhead door west side to code Sister kind stud at bottom plate that has been over notched at garage east side PFH wall Nail corner of garage double overhead door east side to code Strap top plate at entry to garage corner since they do not overlap Fire block top and bottom of HVAC chase in garage Vertically support garage chase in garage drop ceiling every 4 feet on center Install rafter collar ties above 3rd car garage Vertically support ridge beam to hip beams above 3rd car garage Garage anchor bolt in 3rd car garage bottom plate is a 1/2 inch diameter instead of 5/8 foot inch Floor joist above pantry has been notched at the top for water waste line Floor joist above kitchen has been notched at the top for 3 inch waste line Gas line to fireplace is not installed Fire block top of chase in basement bathroom Attach bottom of steel post to Ibeam at stairs going to the basement Tie main ridge beam together with a rafter tie Install electrical nail guard for electrical in master bathroom to master toilet wall Install Boca plate in master linen closet at bottom plate for 4 inch mechanical vent Strap top plate in master bathroom to master closet for not being overlapping Air duct is not installed in the utility room
Driveway Inspection Partial 3/17/2025 3/17/2025 03/17/2025
Misc
Informational
03/17/2025
3-17-25 Dustin A, Dw is formed and compacted. Approved to pour.
Driveway Inspection Passed 3/24/2025 3/24/2025 03/24/2025
Misc
Informational
03/17/2025
3-17-25 Dustin A, Dw is formed and compacted. Approved to pour. 3-24-25 Dustin A, Dw is poured to city specs. Passed
Erosion Control Inspection Residential Failed 4/21/2025 4/21/2025 04/21/2025
Miscellaneous Correction
Corrective Action Required
12/18/2024
-Some silt fence at the front of the property has been damaged and needs to be repaired or replaced -Full erosion control measures must be in place and properly maintained until CofO
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
12/18/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Repair or replace damaged silt fence Full erosion control measures must be in place and properly maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/21/2025
4-21-25 Dustin A, EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Failed - Stop Work 4/23/2025 4/23/2025 04/23/2025
Miscellaneous Correction
Corrective Action Required
04/21/2025
-Some silt fence at the front of the property has been damaged and needs to be repaired or replaced -Full erosion control measures must be in place and properly maintained until CofO
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/21/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Repair or replace damaged silt fence Full erosion control measures must be in place and properly maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/21/2025
4-21-25 Dustin A, EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 4-23-25 Dustin A, erosion control still has not been established
Erosion Control Inspection Residential Partial 4/24/2025 4/24/2025 04/24/2025
Miscellaneous Correction
Corrective Action Required
04/23/2025
-Some silt fence at the front of the property has been damaged and needs to be repaired or replaced -Full erosion control measures must be in place and properly maintained until CofO
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/23/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Repair or replace damaged silt fence Full erosion control measures must be in place and properly maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Resolved
04/24/2025
4-21-25 Dustin A, EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 4-23-25 Dustin A, erosion control still has not been established 4-24-25 Jamie S, Erosion control measures have been put in place.
Occupancy Inspection - Codes Residential Failed 5/29/2025 5/29/2025 05/29/2025
Misc
Corrective Action Required
05/29/2025
-door from garage is not self closing -fire foam gap at double garage door and single garage door at the ceiling -1/2 bath in the entry the light and fan are not working
Occupancy Inspection - Codes Residential Full C of O 5/30/2025 5/30/2025 05/30/2025
Misc
Resolved
05/30/2025
-door from garage is not self closing -fire foam gap at double garage door and single garage door at the ceiling -1/2 bath in the entry the light and fan are not working
Documents & Images
Date Uploaded File Type Document Name
08/23/2024 Lees Summit Residental Permit Application 3900 sw flointrock
08/23/2024 exciseapplication 3900 sw flintrock
08/30/2024 Permit Codes Residential Plan Review
09/05/2024 Approved Plans APPROVED PLANS
09/05/2024 Plot Plan APPROVED PLOT PLAN
09/05/2024 Permit Codes Residential Plan Review
09/05/2024 Permit DS Building Permit
09/05/2024 Receipt Receipt for transaction:2024-007500
09/25/2024 Letter INSPECTION SUMMARY
09/25/2024 Letter INSPECTION SUMMARY
10/11/2024 Letter INSPECTION SUMMARY
10/11/2024 Letter INSPECTION SUMMARY
10/29/2024 Letter INSPECTION SUMMARY
10/29/2024 Letter INSPECTION SUMMARY
10/29/2024 Letter INSPECTION SUMMARY
10/30/2024 Letter INSPECTION SUMMARY
11/20/2024 Letter INSPECTION SUMMARY
11/20/2024 Letter INSPECTION SUMMARY
12/18/2024 Letter INSPECTION SUMMARY
12/18/2024 Letter INSPECTION SUMMARY
12/18/2024 Letter INSPECTION SUMMARY
12/20/2024 Letter INSPECTION SUMMARY
01/21/2025 Letter INSPECTION SUMMARY
01/23/2025 Letter INSPECTION SUMMARY
01/23/2025 Letter INSPECTION SUMMARY
01/23/2025 Letter INSPECTION SUMMARY
01/31/2025 Engineer Report/Study 3900 SW Flintrock
02/05/2025 Letter INSPECTION SUMMARY
03/17/2025 Letter INSPECTION SUMMARY
03/24/2025 Letter INSPECTION SUMMARY
04/21/2025 Letter INSPECTION SUMMARY
04/21/2025 Letter INSPECTION SUMMARY
04/23/2025 Letter Stop Work Order
04/23/2025 Letter Stop Work Order
04/24/2025 Letter INSPECTION SUMMARY
05/27/2025 Receipt Receipt for transaction:2025-003813
05/29/2025 Letter INSPECTION SUMMARY
05/30/2025 Letter Field Certificate of Occupancy
05/30/2025 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home