DJ23 INVESTMENTS LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - ROOF TRUSSES - UNCOVERED DECK
06/27/2024
07/02/2024
01/08/2025
Locations
Contacts
Avital Homes, LLC, Address:7500 W 151st Street, #23100, Phone:(816) 914-7128  
DJ23 INVESTMENTS LLC, Address:7200 W 132ND ST  
Doug Jenson, Address:11010 Nora Dodge Dr, Phone:(816) 266-0685  
DOUG@APGKC.COM  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
CARUTHERS ELECTRICAL LLC, Address:30905 E TRUMAN RD, Phone:(816) 508-9050  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 07/02/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 07/02/2024
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 07/02/2024
8331401-Water Tap Fee $3,973.00 $3,973.00 Paid 07/02/2024
8350015-Water Meter Fee $748.03 $748.03 Paid 07/02/2024
9110078-Valuation Fee New Single Family $1,804.14 $1,804.14 Paid 07/02/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 12/11/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 12/12/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/17/2024 7/17/2024 07/17/2024
Underslab Plumbing Inspection - Residential Not Ready 7/26/2024 7/26/2024 07/26/2024
Underslab Plumbing Inspection - Residential Failed 7/30/2024 7/30/2024 07/30/2024
Misc
Corrective Action Required
07/30/2024
-Rock and gravel covering DWV, remove so inspection can be performed
Erosion Control Inspection Residential Partial 8/16/2024 08/16/2024
Miscellaneous Correction
Informational
08/16/2024
Full erosion control measures are in place and must be maintained until CofO
All Rough Inspection - Residential Failed 8/19/2024 8/19/2024 08/19/2024
Miscellaneous Correction
Informational
08/19/2024
Garage portal framing and front porch truss tie down both passed and are okay to cover. This is a partial pass only. All rough will be scheduled at a later date
Underslab Plumbing Inspection - Residential Partial 8/20/2024 8/20/2024 08/20/2024
Misc
Resolved
08/20/2024
-Rock and gravel covering DWV, remove so inspection can be performed
Miscellaneous Correction
Corrective Action Required
08/20/2024
Underslab dye test completed and passed Plumber needs to upload letter stating why plumbing was covered without inspection This is a partial pass only
Sewer Service Inspection - R Passed 8/20/2024 8/20/2024 08/20/2024
Water Service Inspection - R Failed 8/20/2024 8/20/2024 08/20/2024
Miscellaneous Correction
Informational
08/20/2024
PEX has been run from the foundation to about 15 feet out towards the street and is ok to cover This is a partial pass for water only.
Erosion Control Inspection Residential Partial 8/21/2024 08/21/2024
Miscellaneous Correction
Informational
08/16/2024
Full erosion control measures are in place and must be maintained until CofO
Water Service Inspection - R Passed 8/21/2024 08/21/2024
Miscellaneous Correction
Resolved
08/21/2024
PEX has been run from the foundation to about 15 feet out towards the street and is ok to cover This is a partial pass for water only.
Erosion Control Inspection Residential Failed 9/5/2024 09/05/2024
Miscellaneous Correction
Resolved
09/05/2024
Full erosion control measures are in place and must be maintained until CofO
Miscellaneous Correction
Corrective Action Required
09/05/2024
Gravel needs to be spread from the foundation to the street Full erosion control measures must be maintained until CofO
Underslab Plumbing Inspection - Residential Passed 9/5/2024 09/05/2024
Miscellaneous Correction
Resolved
09/05/2024
Underslab dye test completed and passed Plumber needs to upload letter stating why plumbing was covered without inspection This is a partial pass only
Miscellaneous Correction
Informational
09/05/2024
Dye test was performed and passed
Gas Service Inspection - Residential Passed 9/19/2024 9/19/2024 09/19/2024
Erosion Control Inspection Residential Failed 9/19/2024 09/19/2024
Miscellaneous Correction
Resolved
09/19/2024
Gravel needs to be spread from the foundation to the street Full erosion control measures must be maintained until CofO
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/19/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -Gravel needs to be spread from the foundation to the street (second request) -Erosion control is missing, damaged or no longer effective at the S/E corner of the lot
Electrical Service Inspection Passed 9/19/2024 9/19/2024 09/19/2024
All Rough Inspection - Residential Failed 9/19/2024 9/19/2024 09/19/2024
Miscellaneous Correction
Informational
08/19/2024
Garage portal framing and front porch truss tie down both passed and are okay to cover. This is a partial pass only. All rough will be scheduled at a later date
Erosion Control Inspection Residential Partial 9/24/2024 9/24/2024 09/24/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
09/24/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -Gravel needs to be spread from the foundation to the street (second request) -Erosion control is missing, damaged or no longer effective at the S/E corner of the lot
Miscellaneous Correction
Informational
09/24/2024
Erosion control measures are in place and must be maintained until CofO
All Rough Inspection - Residential Passed 9/26/2024 9/26/2024 09/26/2024
Required access
Resolved
09/26/2024
2018 IFC 3310.1 Required access. Approved vehicle access for fire fighting shall be provided to all construction or demolition sites. Vehicle access shall be provided to within 100 feet (30 480mm) of temporary or permanent fire department connections. Vehicle access shall be provided by either temporary or permanent roads, capable of supporting vehicle loading under all weather conditions. Vehicle access shall be maintained until permanent fire apparatus access roads are available.
Miscellaneous Correction
Resolved
09/26/2024
1808 SW Hightown. All rough •2 1/2x 2 1/2 steel plate for garage anchor bolt for double overhead door is not properly installed •Anchor bolt is missing at sole plate between overhead garage doors •Garage north side anchor bolts need to be placed in the middle 1/3 of sole plate •Fire block the top of both chases in the garage •Fully support both trusses in garage by 3 inch steel column •Nail pantry stud N/W corner to garage wall at top 1/3rd •Fire block top of both chases in living area •Fire block all gaps in floor in office at mechanical •Nails missing in LIB in office •Truss C2 does not have truss screws installed •Replace, repair or install nail in truss brackets in bedroom 3 •Truss tie down screws missing in D11 •BOCA plate needed in his closet to utility room at water lines •Fire block at waste line in stairwell going to basement •Double 2x10 floor joist under kitchen island appears to not be far enough east for proper load transfer support
Piers/Caissons Inspection - Residential Passed 9/26/2024 9/26/2024 09/26/2024
Suspended Slab Inspection Passed 10/11/2024 10/11/2024
Miscellaneous Correction
Informational
10/11/2024
Third party for front porch
Erosion Control Inspection Residential Partial 11/6/2024 11/06/2024
Miscellaneous Correction
Informational
09/24/2024
Erosion control measures are in place and must be maintained until CofO
Driveway Inspection Partial 11/8/2024 11/8/2024 11/08/2024
Misc
Informational
11/08/2024
11-8-24 DP. DW was formed, aggregate compacted. Approved to pour
Sidewalk Inspection Partial 11/8/2024 11/8/2024 11/08/2024
Misc
Informational
11/08/2024
11-8-24 DP. SW was formed, aggregate compacted, cross slopes in compliance but conditions can change. Approved to pour.
Driveway Inspection Passed 11/15/2024 11/15/2024 11/15/2024
Misc
Informational
11/08/2024
11-8-24 DP. DW was formed, aggregate compacted. Approved to pour 11-1524 Dustin A, Dw is poured to city specs. Slopes are in compliance. Pass
Sidewalk Inspection Partial 11/15/2024 11/15/2024 11/15/2024
Misc
Informational
11/08/2024
11-8-24 DP. SW was formed, aggregate compacted, cross slopes in compliance but conditions can change. Approved to pour. 11-15-24 Dustin A, Cannot inspect due to forms and debris on sw. Left side will need another pre pour inspection before they pour. Talked with Doug this morning and let him know
Sidewalk Inspection Failed 12/3/2024 12/3/2024 12/03/2024
Misc
Informational
11/15/2024
11-8-24 DP. SW was formed, aggregate compacted, cross slopes in compliance but conditions can change. Approved to pour. 11-15-24 Dustin A, Cannot inspect due to forms and debris on sw. Left side will need another pre pour inspection before they pour. Talked with Doug this morning and let him know. 12-2-24 Dustin A, Sw on left of approach is formed. Slopes are in compliance. Gravel is to shallow near existing sidewalk/ It is not compacted and their is big chunks of concrete that needs to be removed. Will need another pre pour inspection, Fail. Talked with colby and let him know.
Plot Plan Inspection Passed 12/5/2024 12/05/2024
Occupancy Inspection - Codes Residential Not Ready 12/5/2024 12/5/2024 12/05/2024
Miscellaneous Correction
Corrective Action Required
12/05/2024
House locked and no access code in public notes in city view Not ready
Occupancy Inspection - Codes Residential Failed 12/9/2024 12/9/2024 12/09/2024
Miscellaneous Correction
Resolved
12/09/2024
House locked and no access code in public notes in city view Not ready
Misc
Corrective Action Required
12/09/2024
- double outlet at sprinkler control in garage to be GFCI protected or changed to a single and labeled non-GFCI - Open electrical at master bathroom vanity lights - Outlets at sump/grinder pits to be GFCI protected unless singles and labeled non- GFCI - Basement outlet for networking near panel to be GFCI - Pay all fees - Obtain an irrigation permit and submit a back flow certificate - Provide sod - Sump discharge to be 36” away from foundation - Provide Gutter down spouts splash pads to divert water 36” away from foundation
Erosion Control Inspection Residential Failed 12/9/2024 12/09/2024
Miscellaneous Correction
Resolved
12/09/2024
Erosion control measures are in place and must be maintained until CofO
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
12/09/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Occupancy Inspection - Codes Residential Failed 12/10/2024 12/10/2024 12/10/2024
Misc
Corrective Action Required
12/09/2024
- double outlet at sprinkler control in garage to be GFCI protected or changed to a single and labeled non-GFCI - Outlets at sump/grinder pits to be GFCI protected unless singles and labeled non- GFCI - Basement outlet for networking near panel to be GFCI - Pay all fees - Obtain an irrigation permit and submit a back flow certificate - Sump discharge to be 36” away from foundation - Provide Gutter down spouts splash pads to divert water 36” away from foundation - Raise water meter pit to grade with meter height at 14-18" from lid
Erosion Control Inspection Residential Passed 12/10/2024 12/10/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
12/10/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Sidewalk Inspection Partial 12/10/2024 12/10/2024 12/10/2024
Misc
Informational
12/03/2024
11-8-24 DP. SW was formed, aggregate compacted, cross slopes in compliance but conditions can change. Approved to pour. 11-15-24 Dustin A, Cannot inspect due to forms and debris on sw. Left side will need another pre pour inspection before they pour. Talked with Doug this morning and let him know. 12-2-24 Dustin A, Sw on left of approach is formed. Slopes are in compliance. Gravel is to shallow near existing sidewalk/ It is not compacted and their is big chunks of concrete that needs to be removed. Will need another pre pour inspection, Fail. Talked with colby and let him know. 12-10-24 Dustin A, sw that is missing has been formed and compacted, slopes are in compliance. Approved to pour
Occupancy Inspection - Codes Residential Failed 12/11/2024 12/11/2024 12/11/2024
Misc
Corrective Action Required
12/10/2024
- Pay all fees -Address pending sidewalk inspection - Obtain an irrigation permit and submit a back flow certificate - Raise water meter pit to grade with meter height at 14-18" from lid
Occupancy Inspection - Codes Residential Ready for Temp CO 12/12/2024 12/12/2024 12/12/2024
Misc
Corrective Action Required
12/11/2024
- Pay all fees -Address pending sidewalk inspection - Obtain an irrigation permit and submit a back flow certificate - Raise water meter pit to grade with meter height at 14-18" from lid
Sidewalk Inspection Partial 12/17/2024 12/17/2024 12/17/2024
Misc
Informational
12/10/2024
11-8-24 DP. SW was formed, aggregate compacted, cross slopes in compliance but conditions can change. Approved to pour. 11-15-24 Dustin A, Cannot inspect due to forms and debris on sw. Left side will need another pre pour inspection before they pour. Talked with Doug this morning and let him know. 12-2-24 Dustin A, Sw on left of approach is formed. Slopes are in compliance. Gravel is to shallow near existing sidewalk/ It is not compacted and their is big chunks of concrete that needs to be removed. Will need another pre pour inspection, Fail. Talked with colby and let him know. 12-10-24 Dustin A, sw that is missing has been formed and compacted, slopes are in compliance. Approved to pour 12-17-24 Dustin A, SW has been poured to city specs and slopes are in compliance. Cannot pass until forms pulled
Occupancy Inspection - Codes Residential Failed 12/27/2024 12/27/2024 12/27/2024
Misc
Resolved
12/27/2024
- Pay all fees -Address pending sidewalk inspection - Obtain an irrigation permit and submit a back flow certificate - Raise water meter pit to grade with meter height at 14-18" from lid
Miscellaneous Correction
Corrective Action Required
12/27/2024
-Address pending sidewalk inspection
Sidewalk Inspection Passed 1/2/2025 1/2/2025 01/02/2025
Misc
Informational
12/17/2024
11-8-24 DP. SW was formed, aggregate compacted, cross slopes in compliance but conditions can change. Approved to pour. 11-15-24 Dustin A, Cannot inspect due to forms and debris on sw. Left side will need another pre pour inspection before they pour. Talked with Doug this morning and let him know. 12-2-24 Dustin A, Sw on left of approach is formed. Slopes are in compliance. Gravel is to shallow near existing sidewalk/ It is not compacted and their is big chunks of concrete that needs to be removed. Will need another pre pour inspection, Fail. Talked with colby and let him know. 12-10-24 Dustin A, sw that is missing has been formed and compacted, slopes are in compliance. Approved to pour 12-17-24 Dustin A, SW has been poured to city specs and slopes are in compliance. Cannot pass until forms pulled 01-02-25 Jamie S, Forms have been pulled. Passed
Occupancy Inspection - Codes Residential Full C of O 1/8/2025 1/8/2025 01/08/2025
Miscellaneous Correction
Resolved
01/08/2025
-Address pending sidewalk inspection
Documents & Images
Date Uploaded File Type Document Name
06/27/2024 RS 99 License_Tax_Application Signed
06/27/2024 RS 99 Permit Application Signed
06/27/2024 Approved Plans APPROVED PLANS
06/27/2024 Plot Plan APPROVED PLOT PLAN
06/27/2024 Approved Plans APPROVED TRUSS LAYOUT
07/01/2024 Permit Codes Residential Plan Review
07/02/2024 Permit DS Building Permit
07/02/2024 Receipt Receipt for transaction:2024-005470
07/17/2024 Letter INSPECTION SUMMARY
07/26/2024 Letter INSPECTION SUMMARY
07/30/2024 Letter INSPECTION SUMMARY
08/16/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/20/2024 Letter INSPECTION SUMMARY
08/20/2024 Letter INSPECTION SUMMARY
08/20/2024 Letter INSPECTION SUMMARY
08/21/2024 Letter INSPECTION SUMMARY
08/21/2024 Letter INSPECTION SUMMARY
09/03/2024 Letter RMS letter (underslab plumbing)
09/05/2024 Letter INSPECTION SUMMARY
09/05/2024 Letter INSPECTION SUMMARY
09/19/2024 Letter INSPECTION SUMMARY
09/19/2024 Letter INSPECTION SUMMARY
09/24/2024 Letter INSPECTION SUMMARY
09/26/2024 Letter INSPECTION SUMMARY
09/26/2024 Letter INSPECTION SUMMARY
09/26/2024 Letter INSPECTION SUMMARY
09/26/2024 Letter INSPECTION SUMMARY
10/09/2024 2024_10_07_1808 SW Hightown Dr_LSMO_Stoop-Sealed
10/11/2024 Letter INSPECTION SUMMARY
11/06/2024 Letter INSPECTION SUMMARY
11/08/2024 Letter INSPECTION SUMMARY
11/08/2024 Letter INSPECTION SUMMARY
11/15/2024 Letter INSPECTION SUMMARY
11/15/2024 Letter INSPECTION SUMMARY
11/15/2024 Letter INSPECTION SUMMARY
12/03/2024 Letter INSPECTION SUMMARY
12/03/2024 Letter INSPECTION SUMMARY
12/05/2024 Letter INSPECTION SUMMARY
12/05/2024 Letter INSPECTION SUMMARY
12/09/2024 Letter INSPECTION SUMMARY
12/09/2024 Letter INSPECTION SUMMARY
12/10/2024 Letter INSPECTION SUMMARY
12/10/2024 Letter INSPECTION SUMMARY
12/10/2024 Letter INSPECTION SUMMARY
12/11/2024 Letter INSPECTION SUMMARY
12/11/2024 Receipt Receipt for transaction:2024-009444
12/12/2024 Certificate/License Codes Temporary Certificate of Occupancy
12/12/2024 Receipt Receipt for transaction:2024-009467
12/17/2024 Letter INSPECTION SUMMARY
12/27/2024 Letter INSPECTION SUMMARY
01/02/2025 Letter INSPECTION SUMMARY
01/02/2025 Letter INSPECTION SUMMARY
01/08/2025 Letter Codes Final Certificate of Occupancy
01/08/2025 Letter Field Certificate of Occupancy
01/08/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home