Permit Application Status

PRRES20243203


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20243203
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED PATIO
06/21/2024
06/26/2024
05/06/2025
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
Ashley Kirby, Address:5207 NW Crooked Rd, Phone:(816) 969-9010  
ASHLEY@NEWMARKHOMESKC.COM  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 06/26/2024
Right of Way Permit Fee $85.00 $85.00 Paid 06/26/2024
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 06/26/2024
Water Tap Fee $3,760.00 $3,760.00 Paid 06/26/2024
Water Meter Fee $680.46 $680.46 Paid 06/26/2024
Valuation Fee New Single Family $1,838.24 $1,838.24 Paid 06/26/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 03/28/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 04/23/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/18/2024 07/18/2024
Misc
Informational
07/18/2024
UFER North wall 5 foot West of garage wall.
Erosion Control Inspection Residential Partial 7/18/2024 07/18/2024
Misc
Corrective Action Required
07/18/2024
Ok at time of inspection.
Erosion Control Inspection Residential Partial 8/15/2024 8/15/2024 08/15/2024
Misc
Corrective Action Required
07/18/2024
Ok at time of inspection.
Underslab Plumbing Inspection - Residential Passed 8/15/2024 8/15/2024 08/15/2024
Sewer Service Inspection - R Passed 8/20/2024 8/20/2024 08/20/2024
Water Service Inspection - R Passed 8/23/2024 8/23/2024 08/23/2024
Erosion Control Inspection Residential Failed 10/08/2024
Misc
Resolved
10/08/2024
Ok at time of inspection.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/08/2024
10/8/24 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Restore silt fence, remove trash from lot
Gas Service Inspection - Residential Failed 12/9/2024 12/9/2024 12/09/2024
Misc
Corrective Action Required
12/09/2024
Inspection denied -Post address
Electrical Service Inspection Failed 12/9/2024 12/9/2024 12/09/2024
Misc
Corrective Action Required
12/09/2024
Inspection denied -Post address
Erosion Control Inspection Residential Failed 12/09/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/08/2024
10/8/24 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Post address
All Rough Inspection - Residential Failed 12/12/2024 12/12/2024 12/12/2024
Miscellaneous Correction
Corrective Action Required
12/12/2024
-Portal frame covered without inspection -Nail exterior corners per code -Studs at portal frame not connected to header -Splice at PFH not in middle 24” of portal leg -Bearing studs at garage I beam are over notched -Rafters landing on blocks at garage, joists and rafters not connected to top plates -Structural straps at over bored top plates must extend 6” beyond the hole both directions -Hip joists landing on blocks -Tighten anchor bolts at garage -Rafters landing on cripple wall not connected to ceiling joists -Nail (3) 2x4’s at kitchen -protect all nm 6” above floor at kitchen -Support dwv in attic space per code and provide proper slope -missing joist hangers at laundry -Provide lateral restraint at LVL in kitchen -Correct cut joist hanger at dining -provide lateral restraint at LVL beams -Nail ALL stud packs per code -Roof load bearing on ceiling joists in owners suite -Strap over bored top plates must extend at master bath -Ceiling joists over notched at front bed. Also missing joist hangers -Nail all rafters and ceiling joists per code -Missing nails at basement closet joist hanger -Nail all double 2x10s per code -1/2” plywood not approved for fireblocking at basement -Missing (4) 2x6 at back basement corner by beam per plan -Nail exterior braced wall panels per code
Electrical Service Inspection Passed 12/12/2024 12/12/2024 12/12/2024
Misc
Resolved
12/12/2024
Inspection denied -Post address
Gas Service Inspection - Residential Passed 12/12/2024 12/12/2024 12/12/2024
Misc
Resolved
12/12/2024
Inspection denied -Post address
All Rough Inspection - Residential Failed 12/18/2024 12/18/2024 12/18/2024
Miscellaneous Correction
Corrective Action Required
12/12/2024
-Nail splice at PFH -Structural straps at over bored top plates must extend 6” beyond the hole both directions and have 4 10d nails each side -Tighten anchor bolts at garage -Rafters landing on cripple wall not connected to ceiling joists -Ceiling joists over notched at front bed. Also missing joist hangers-missing hanger in closet -1/2” plywood not approved for fireblocking at basement-seal gaps *ok to insulate
All Rough Inspection - Residential Passed 12/19/2024 12/19/2024 12/19/2024
Miscellaneous Correction
Resolved
12/19/2024
-Nail splice at PFH -Structural straps at over bored top plates must extend 6” beyond the hole both directions and have 4 10d nails each side -Tighten anchor bolts at garage -Rafters landing on cripple wall not connected to ceiling joists -Ceiling joists over notched at front bed. Also missing joist hangers-missing hanger in closet -1/2” plywood not approved for fireblocking at basement-seal gaps *ok to insulate
Driveway Inspection Partial 2/4/2025 2/4/2025 02/04/2025
Misc
Informational
02/04/2025
02/04/25 Tuesday JMJ pre-inspection for driveway passed.
Driveway Inspection Passed 2/6/2025 2/6/2025 02/10/2025
Misc
Informational
02/04/2025
02/04/25 Tuesday JMJ pre-inspection for driveway passed. 02/07/25 Friday Driveway passed final inspection.
Erosion Control Inspection Residential Failed 02/11/2025
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
12/09/2024
2/11/25 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Restore erosion control methods at perimeter
Erosion Control Inspection Residential Failed 03/18/2025
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/18/2025
2/11/25 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Restore erosion control methods at perimeter
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/18/2025
3/18/25 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Re establish erosion control at perimeter
Erosion Control Inspection Residential Partial 3/28/2025 03/28/2025
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/18/2025
2/11/25 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Restore erosion control methods at perimeter
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/18/2025
3/18/25 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Re establish erosion control at perimeter
Erosion Control Inspection Residential Partial 03/28/2025
DCM2 ESC DEFICIENT INSTALLATION
Resolved
03/28/2025
2/11/25 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Restore erosion control methods at perimeter
DCM3 ESC REQUIRED 2 DAY
Resolved
03/28/2025
3/18/25 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Re establish erosion control at perimeter
Plot Plan Inspection Passed 3/28/2025 03/28/2025
Occupancy Inspection - Codes Residential Ready for Temp CO 3/28/2025 3/28/2025 03/28/2025
Misc
Corrective Action Required
03/28/2025
-Complete final grade, sod, splash blocks and irrigation
Occupancy Inspection - Codes Residential Ready for Temp CO 04/23/2025
Misc
Corrective Action Required
03/28/2025
-Complete final grade, sod, splash blocks and irrigation
Erosion Control Inspection Residential Passed 5/6/2025 5/6/2025 05/06/2025
Occupancy Inspection - Codes Residential Full C of O 5/6/2025 5/6/2025 05/06/2025
Misc
Resolved
05/06/2025
-Complete final grade, sod, splash blocks and irrigation
Documents & Images
Date Uploaded File Type Document Name
06/21/2024 Application Form WR191 - Lee's Summit Permit Application Packet_pdf191
06/26/2024 Permit Codes Residential Plan Review
06/26/2024 Approved Plans APPROVED PLANS
06/26/2024 Plot Plan APPROVED PLOT PLAN
06/26/2024 Permit DS Building Permit
06/26/2024 Receipt Receipt for transaction:2024-005187
07/18/2024 Letter INSPECTION SUMMARY
07/18/2024 Letter INSPECTION SUMMARY
08/15/2024 Letter INSPECTION SUMMARY
08/15/2024 Letter INSPECTION SUMMARY
08/19/2024 2238 NW Killarney Ln_ALL SLAB INSP_2024-08-16
08/20/2024 Letter INSPECTION SUMMARY
08/23/2024 Letter INSPECTION SUMMARY
10/08/2024 Letter INSPECTION SUMMARY
12/09/2024 Letter INSPECTION SUMMARY
12/09/2024 Letter INSPECTION SUMMARY
12/09/2024 Letter INSPECTION SUMMARY
12/12/2024 Letter INSPECTION SUMMARY
12/12/2024 Letter INSPECTION SUMMARY
12/12/2024 Letter INSPECTION SUMMARY
12/12/2024 Letter INSPECTION SUMMARY
12/18/2024 Letter INSPECTION SUMMARY
12/19/2024 Letter INSPECTION SUMMARY
02/04/2025 Letter INSPECTION SUMMARY
02/10/2025 Letter INSPECTION SUMMARY
02/11/2025 Letter INSPECTION SUMMARY
03/18/2025 Letter INSPECTION SUMMARY
03/28/2025 Letter INSPECTION SUMMARY
03/28/2025 Letter INSPECTION SUMMARY
03/28/2025 Letter INSPECTION SUMMARY
03/28/2025 Letter INSPECTION SUMMARY
03/28/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/28/2025 Receipt Receipt for transaction:2025-001879
04/22/2025 Application Form TCO EXTENSION REQUEST
04/23/2025 Letter INSPECTION SUMMARY
04/23/2025 Certificate/License Codes Temporary Certificate of Occupancy
04/23/2025 Receipt Receipt for transaction:2025-002532
05/06/2025 Letter INSPECTION SUMMARY
05/06/2025 Letter Codes Final Certificate of Occupancy
05/06/2025 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home