Permit Application Status

PRRES20243057


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20243057
Building Permit - Residential
Issued
TRAILS OF PARK RIDGE LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED PORCH
06/13/2024
09/09/2024
12/10/2024
Locations
Contacts
CAPITAL CONSTRUCTION SERVICES LLC, Address:2642 NE HAGAN RD, Phone:(816) 875-0018  
TRAILS OF PARK RIDGE LLC, Address:3170 NE CARNEGIE DR STE 400  
Doug Rothfuss, Address:2642 HAGAN RD  
DROTHFUSS@CAPITALCONST.COM  
FIVE STAR MECHANICAL CONTRACT INC, Address:P O BOX 11964, Phone:(816) 358-4444  
INHOME SYSTEMS LLC, Address:510 MISSION RD SW, Phone:(816) 372-0483  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 09/09/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 09/09/2024
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 09/09/2024
8331401-Water Tap Fee $3,973.00 $3,973.00 Paid 09/09/2024
8350015-Water Meter Fee $748.03 $748.03 Paid 09/09/2024
9110078-Valuation Fee New Single Family $1,468.99 $1,468.99 Paid 09/09/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Plot Plan Inspection Pending
Occupancy Inspection - Codes Residential Pending
Erosion Control Inspection Residential Pending
Misc
Informational
12/23/2024
Erosion control in compliance at time of inspection
Driveway Inspection Pending
Misc
Informational
04/07/2025
4-7-25 NS Site visited for a pre pour inspection and it appears that sidewalk and driveway meet city standards. Will come back when house is in rough inspection to pass driveway.
Erosion Control Inspection Residential Partial 10/3/2024 10/03/2024
Misc
Informational
10/03/2024
Erosion control in compliance at time of inspection
Footing Inspection - Residential Passed 10/03/2024
Informational
10/03/2024
Footing approved by engineer
Underslab Plumbing Inspection - Residential Passed 10/3/2024 10/3/2024 10/03/2024
Erosion Control Inspection Residential Partial 11/21/2024 11/21/2024
Misc
Informational
10/03/2024
Erosion control in compliance at time of inspection
Sewer Service Inspection - R Passed 11/21/2024 11/21/2024 11/21/2024
Erosion Control Inspection Residential Partial 11/25/2024 11/25/2024
Misc
Informational
11/21/2024
Erosion control in compliance at time of inspection
Water Service Inspection - R Passed 11/25/2024 11/25/2024 11/25/2024
Erosion Control Inspection Residential Partial 12/13/2024 12/13/2024
Misc
Informational
11/25/2024
Erosion control in compliance at time of inspection
Erosion Control Inspection Residential Partial 12/13/2024 12/13/2024
Misc
Informational
12/13/2024
Erosion control in compliance at time of inspection
Gas Service Inspection - Residential Passed 12/13/2024 12/13/2024 12/13/2024
Electrical Service Inspection Passed 12/13/2024 12/13/2024
All Rough Inspection - Residential Failed 12/13/2024 12/13/2024 12/13/2024
Misc
Corrective Action Required
12/13/2024
-Install box extension for receptacle box recessed behind combustible wall finish (near AC) -Fb laundry wall from roof space -Fb b-vent space from roof space -Provide insulation shield for b-vent in attic; provide min 1” clearance from roof deck -The end of each rafter must have min 1.5” of bearing -Brace cripple wall above kitchen -Provide full support for lvl hip at exterior kitchen wall; hip is over-notched -Provide security blockings at rear exterior door per security code; fill in void between stud and door frame at strike side from 12” below to 12” above strike plate and at hinges -Secure ceiling light circuit above kitchen -Protect wiring at great room bottom wall plate; at front bedroom bottom wall plate; at top plate of basement stair wall; at ceiling of bedroom 4 -Cannot insulate before inspection -Fb basement wall space vertically at max 10 ft intervals; fb wall from soffit space throughout; fb rear wall of basement gaming from joist -Anchor basement sill plate within 12” of break -Lower ducting to basement bathroom ceiling level -Install 3”-4” transition fitting for basement bathroom fan. There are several unused ones above master bathroom -Unblock return air space at bedroom 3 -Provide combustion air openings (min 100 sq inches per opening) **DO NOT INSULATE
Erosion Control Inspection Residential Partial 12/17/2024 12/17/2024
Misc
Informational
12/13/2024
Erosion control in compliance at time of inspection
All Rough Inspection - Residential Failed 12/17/2024 12/17/2024 12/17/2024
Misc
Corrective Action Required
12/13/2024
-The end of each rafter must have min 1.5” of bearing -Brace cripple wall above kitchen -Provide full support for lvl hip at exterior kitchen wall; hip is over-notched -Fill in void between stud and door frame at strike side from 12” below to 12” above strike plate and at hinges -Provide combustion air openings (min 100 sq inches per opening) **OK TO INSULATE
Erosion Control Inspection Residential Partial 12/23/2024 12/23/2024
Misc
Informational
12/17/2024
Erosion control in compliance at time of inspection
All Rough Inspection - Residential Passed 12/23/2024 12/23/2024 12/23/2024
Misc
Resolved
12/23/2024
-The end of each rafter must have min 1.5” of bearing -Brace cripple wall above kitchen -Provide full support for lvl hip at exterior kitchen wall; hip is over-notched -Fill in void between stud and door frame at strike side from 12” below to 12” above strike plate and at hinges -Provide combustion air openings (min 100 sq inches per opening) **OK TO INSULATE
Piers/Caissons Inspection - Residential Passed 3/12/2025 3/12/2025 03/12/2025
Driveway Inspection Partial 4/7/2025 4/7/2025 04/07/2025
Misc
Informational
04/07/2025
4-7-25 NS Site visited for a pre pour inspection and it appears that sidewalk and driveway meet city standards. Will come back when house is in rough inspection to pass driveway.
Documents & Images
Date Uploaded File Type Document Name
06/13/2024 Lot 46 - Permit App
06/17/2024 Permit Codes Residential Plan Review
06/17/2024 Approved Plans APPROVED PLANS
06/17/2024 Plot Plan APPROVED PLOT PLAN
09/09/2024 Permit DS Building Permit
09/09/2024 Receipt Receipt for transaction:2024-007540
09/17/2024 3RD Party Insp Report THIRD PARTY FOOTING INSPECTION REPORT
10/03/2024 Letter INSPECTION SUMMARY
10/03/2024 Letter INSPECTION SUMMARY
10/03/2024 Letter INSPECTION SUMMARY
11/21/2024 Letter INSPECTION SUMMARY
11/21/2024 Letter INSPECTION SUMMARY
11/25/2024 Letter INSPECTION SUMMARY
11/25/2024 Letter INSPECTION SUMMARY
12/13/2024 Letter INSPECTION SUMMARY
12/13/2024 Letter INSPECTION SUMMARY
12/13/2024 Letter INSPECTION SUMMARY
12/13/2024 Letter INSPECTION SUMMARY
12/13/2024 Letter INSPECTION SUMMARY
12/17/2024 Letter INSPECTION SUMMARY
12/23/2024 Letter INSPECTION SUMMARY
03/12/2025 Letter INSPECTION SUMMARY
03/12/2025 Letter INSPECTION SUMMARY
03/12/2025 Letter INSPECTION SUMMARY
04/07/2025 Letter INSPECTION SUMMARY
Upload Documents
  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:
Browse..





    Portal Home