Permit Application Status

PRRES20242599


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20242599
Building Permit - Residential
Certificate of Occupancy
DOMAIN TIMBERLAKE MULTISTATE LLC
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. WALKOUT BASEMENT. COVERED DECK. ROOF TRUSSES. STOP WORK ORDER generated on 06/27/2024 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 06/28/2024 12:00 AM by username 'Mitchell Schwarz'.
05/21/2024
06/03/2024
11/25/2024
01/02/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
DOMAIN TIMBERLAKE MULTISTATE LLC, Address:590 MADISON AVE FL 13TH  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
TYLER@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $3,760.00 $3,760.00 Paid 06/03/2024
Water Meter Fee $680.46 $680.46 Paid 06/03/2024
Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 06/03/2024
Right of Way Permit Fee $85.00 $85.00 Paid 06/03/2024
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 06/03/2024
Valuation Fee New Single Family $1,388.68 $1,388.68 Paid 06/03/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 11/26/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 11/26/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 6/27/2024 6/27/2024 06/27/2024
Footing Inspection - Residential Failed - Stop Work 6/27/2024 06/27/2024
Misc
Corrective Action Required
06/27/2024
Footing poured without inspection. Stop work issued
Footing Inspection - Residential Passed 6/28/2024 06/28/2024
Misc
Resolved
06/28/2024
Footing poured without inspection. Stop work issued
Water Service Inspection - R Passed 6/28/2024 06/28/2024
Underslab Plumbing Inspection - Residential Failed 7/16/2024 7/16/2024 07/16/2024
Misc
Corrective Action Required
07/16/2024
Complete sump pump drainage and pit install
Underslab Plumbing Inspection - Residential Passed 7/17/2024 7/17/2024 07/17/2024
Misc
Resolved
07/17/2024
Complete sump pump drainage and pit install
Electrical Service Inspection Passed 9/23/2024 9/23/2024 09/23/2024
All Rough Inspection - Residential Failed 9/23/2024 9/23/2024 09/23/2024
Misc
Corrective Action Required
09/23/2024
-install all roof boots throughout -provide truss plans on site -nail plate under PFH to headed to plans -seal dead space to ceiling space at owners entry closet -seal top plate penetration garage/bed 3 -address electrical not landed above bed 3 -address NE basement exterior wall corner framing (over notched studs, using 2x4 instead of 2x6) -address all over notched studs in basement -missing nut on anchor bolt at E wall in basement -provide blocking per plans under island -anchor steel columns in basement -address floor joist over notched and notched in the middle 1/3 for driver vent above -missing nails in hanger for header at return air -provide blocking above beams in basement where missing -anchor bolts to be in the middle within 12” of plate breaks but not closer than 7x the diameter of the bolt -uncover covered front porch
All Rough Inspection - Residential Failed 9/27/2024 9/27/2024 09/27/2024
Misc
Corrective Action Required
09/23/2024
-address electrical not landed above bed 3
All Rough Inspection - Residential Passed 10/3/2024 10/3/2024 10/03/2024
Misc
Resolved
10/03/2024
-address electrical not landed above bed 3
Gas Service Inspection - Residential Passed 10/3/2024 10/3/2024 10/03/2024
Piers/Caissons Inspection - Residential Passed 11/12/2024 11/12/2024 11/12/2024
Driveway Inspection Partial 11/14/2024 11/14/2024 11/14/2024
Misc
Informational
11/14/2024
10-13-24 Dustin A, Curb and driveway has been formed and compacted to city specs, Approved to pour
Sidewalk Inspection Partial 11/14/2024 11/14/2024 11/14/2024
Misc
Informational
11/14/2024
10-13-24 Dustin A, sw has been formed and compacted and slopes are in compliance. Approved to pour
Sidewalk Inspection Passed 11/21/2024 11/21/2024 11/21/2024
Misc
Informational
11/21/2024
11-21-24 Dustin A, SW is poured to city specs, Slopes are in compliance. Passed
Driveway Inspection Passed 11/21/2024 11/21/2024 11/21/2024
Misc
Informational
11/14/2024
10-13-24 Dustin A, Curb and driveway has been formed and compacted to city specs, Approved to pour 11-21-24 Dustin A, DW has been poured to city specs and slopes are in compliance. Passed
Occupancy Inspection - Codes Residential Not Ready 11/22/2024 11/22/2024 11/22/2024
Misc
Corrective Action Required
11/22/2024
1628 sw buckthorn - provide guard for front porch ( over 30” above grade) - Second story sliding door with no deck built - NO THERMOSTAT - Inspection incomplete, too many life safety issues NOT READY
Plot Plan Inspection Passed 11/22/2024 11/22/2024
Erosion Control Inspection Residential Failed 11/22/2024 11/22/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
11/22/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Occupancy Inspection - Codes Residential Failed 11/25/2024 11/25/2024 11/25/2024
Misc
Resolved
11/25/2024
1628 sw buckthorn - provide guard for front porch ( over 30” above grade) - Second story sliding door with no deck built - NO THERMOSTAT - Inspection incomplete, too many life safety issues NOT READY
Miscellaneous Correction
Corrective Action Required
11/25/2024
•Fire block gaps in sheet rock in garage above overhead doors •Identify electrical receptacle in garage as non GFCI protected •Thermostat not installed •Nails missing for joist hanger on back deck •Exterior A/C system s not installed •Sod, splash pads and sump pump extension are not installed •eal exterior penetrations •Pay $75 fee associated with this permit
Erosion Control Inspection Residential Partial 11/25/2024 11/25/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
11/25/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Miscellaneous Correction
Informational
11/25/2024
Erosion control is in place and must be properly maintained until CofO
Occupancy Inspection - Codes Residential Ready for Temp CO 11/26/2024 11/26/2024 11/26/2024
Miscellaneous Correction
Resolved
11/26/2024
•Identify electrical receptacle in garage as non GFCI protected •Thermostat not installed •Nails missing for joist hanger on back deck •Exterior A/C system s not installed •Sod, splash pads and sump pump extension are not installed •eal exterior penetrations •Pay $75 fee associated with this permit
Miscellaneous Correction
Corrective Action Required
11/26/2024
•Sod, splash pads and sump pump extension are not installed •Pay $75 fee associated with this permit Pass for TCO only
Erosion Control Inspection Residential Passed 01/02/2025
Miscellaneous Correction
Resolved
01/02/2025
Erosion control is in place and must be properly maintained until CofO
Occupancy Inspection - Codes Residential Full C of O 1/2/2025 01/02/2025
Miscellaneous Correction
Resolved
01/02/2025
•Sod, splash pads and sump pump extension are not installed •Pay $75 fee associated with this permit Pass for TCO only
Documents & Images
Date Uploaded File Type Document Name
05/21/2024 HT #165 - PERMIT APP
05/29/2024 Permit Codes Residential Plan Review
05/31/2024 Plot Plan APPROVED PLOT PLAN
05/31/2024 Approved Plans APPROVED PLANS
05/31/2024 Approved Plans APPROVED TRUSS PACKAGE
05/31/2024 Approved Plans APPROVED TRUSS LAYOUT
05/31/2024 Permit Codes Residential Plan Review
06/03/2024 Permit DS Building Permit
06/03/2024 Receipt Receipt for transaction:2024-004249
06/27/2024 Letter Stop Work Order
06/27/2024 Letter INSPECTION SUMMARY
06/27/2024 3RD Party Insp Report M L Crose 1628 SW Buckthorn St LSMO Foundation Footing Inspection Report 6-11-24
06/28/2024 Letter INSPECTION SUMMARY
06/28/2024 Letter INSPECTION SUMMARY
07/16/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
09/23/2024 Letter INSPECTION SUMMARY
09/23/2024 Letter INSPECTION SUMMARY
09/27/2024 Letter INSPECTION SUMMARY
10/03/2024 Letter INSPECTION SUMMARY
10/03/2024 Letter INSPECTION SUMMARY
11/12/2024 Letter INSPECTION SUMMARY
11/14/2024 Letter INSPECTION SUMMARY
11/14/2024 Letter INSPECTION SUMMARY
11/21/2024 Letter INSPECTION SUMMARY
11/21/2024 Letter INSPECTION SUMMARY
11/22/2024 Letter INSPECTION SUMMARY
11/22/2024 Letter INSPECTION SUMMARY
11/22/2024 Letter INSPECTION SUMMARY
11/25/2024 Letter INSPECTION SUMMARY
11/25/2024 Letter INSPECTION SUMMARY
11/26/2024 Letter INSPECTION SUMMARY
11/26/2024 Certificate/License Codes Temporary Certificate of Occupancy
11/26/2024 Receipt Receipt for transaction:2024-009174
01/02/2025 Letter INSPECTION SUMMARY
01/02/2025 Letter Field Certificate of Occupancy
01/02/2025 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home