Permit Application Status

PRRES20242541


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20242541
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK
05/19/2024
05/28/2024
04/17/2025
Locations
Contacts
WALKER CUSTOM HOMES, LLC, Address:PO BOX 3194, Phone:(913) 208-2026  
Jason walker, Address:PO Box 247, Phone:(913) 208-2026  
WALKERCUSTOMHOMESKC@GMAIL.COM  
5 STAR MECHANICAL, LLC, Address:PO BOX 793, Phone:(816) 679-0375  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 05/28/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 05/28/2024
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 05/28/2024
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 05/28/2024
8350015-Water Meter Fee $680.46 $680.46 Paid 05/28/2024
9110078-Valuation Fee New Single Family $1,764.48 $1,764.48 Paid 05/28/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Partial 7/2/2024 07/02/2024
Miscellaneous Correction
Informational
07/02/2024
Full erosion control is in place and must be maintained until CofO
Footing Inspection - Residential Failed 7/2/2024 07/02/2024
Miscellaneous Correction
Corrective Action Required
07/02/2024
Piers were noted on the footing inspection but did not provide enough information on them. Please submit the following information on the piers and then reschedule a footing inspection A) quantity B) location C) size D) depth
Sewer Service Inspection - R Failed 7/5/2024 07/05/2024
Miscellaneous Correction
Corrective Action Required
07/05/2024
Sewer passed and is okay to cover Footing needs to pass before sewer can be completed and passed
Water Service Inspection - R Failed 7/5/2024 07/05/2024
Miscellaneous Correction
Corrective Action Required
07/05/2024
Water line has been run out from under the foundation to a point of 20 feet towards the street Okay to cover This is a partial pass only Water failed due to the footing inspection not passing
Footing Inspection - Residential Passed 7/8/2024 07/08/2024
Miscellaneous Correction
Resolved
07/08/2024
Piers were noted on the footing inspection but did not provide enough information on them. Please submit the following information on the piers and then reschedule a footing inspection A) quantity B) location C) size D) depth
Piers/Caissons Inspection - Residential Partial 7/8/2024 07/08/2024
Miscellaneous Correction
Informational
07/08/2024
Footing piers passed by a third party
Water Service Inspection - R Passed 7/8/2024 07/08/2024
Miscellaneous Correction
Resolved
07/08/2024
Water line has been run out from under the foundation to a point of 20 feet towards the street Okay to cover This is a partial pass only Water failed due to the footing inspection not passing
Sewer Service Inspection - R Passed 7/8/2024 07/08/2024
Miscellaneous Correction
Resolved
07/08/2024
Sewer passed and is okay to cover Footing needs to pass before sewer can be completed and passed
Underslab Plumbing Inspection - Residential Passed 7/10/2024 7/10/2024 07/10/2024
Erosion Control Inspection Residential Failed 7/10/2024 7/10/2024 07/10/2024
Miscellaneous Correction
Resolved
07/10/2024
Full erosion control is in place and must be maintained until CofO
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/10/2024
7/10/24 -Maintain gravel filter with min 6" lift of min 3/4" gravel -Remove loose trash on site
Erosion Control Inspection Residential Partial 8/26/2024 08/26/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
08/26/2024
7/10/24 -Maintain gravel filter with min 6" lift of min 3/4" gravel -Remove loose trash on site
Miscellaneous Correction
Informational
08/26/2024
Erosion control measures are in place and must be maintained until CofO
Gas Service Inspection - Residential Passed 10/16/2024 10/16/2024 10/16/2024
Electrical Service Inspection Passed 10/16/2024 10/16/2024 10/16/2024
Erosion Control Inspection Residential Partial 10/16/2024 10/16/2024
Miscellaneous Correction
Informational
08/26/2024
Erosion control measures are in place and must be maintained until CofO
All Rough Inspection - Residential Failed 10/16/2024 10/16/2024 10/16/2024
Miscellaneous Correction
Corrective Action Required
10/16/2024
929 SW Flintrock All rough -Garage anchor bolts are not located in the middle 1/3 of sole plate at PFH -Electrical nail guard is needed in corner of bedroom 2 -1/3 of hip LVL above bedroom 2 has been cut to lay on top of top plate. Vertically support all of LVL -Nail N/E corner of bedroom 2 to code -Nail double LVL to king stud in corner of great room above floating shelves -Snow block step flashing above floating shelf’s in great room -2 steel columns in the basement have 3 inch columns installed instead of 3 1/2 inches -Electrical nail guards are needed in bedroom 4 east wall -Upload third party pier inspection for back deck -Upload type of fastener used for back deck post to beam connection -Install anchor bolt in bottom sole plate in basement next to uninstalled sliding patio door -Add missing 3 studs under Ibeam in basement between patio door and window and support the header on the west side under the same Ibeam -Install anchor bolts in the middle 1/3 of sole plate in basement east wall
All Rough Inspection - Residential Failed 11/7/2024 11/7/2024 11/07/2024
Miscellaneous Correction
Resolved
11/07/2024
929 SW Flintrock All rough -Garage anchor bolts are not located in the middle 1/3 of sole plate at PFH -Electrical nail guard is needed in corner of bedroom 2 -1/3 of hip LVL above bedroom 2 has been cut to lay on top of top plate. Vertically support all of LVL -Nail N/E corner of bedroom 2 to code -Nail double LVL to king stud in corner of great room above floating shelves -Snow block step flashing above floating shelf’s in great room -2 steel columns in the basement have 3 inch columns installed instead of 3 1/2 inches -Electrical nail guards are needed in bedroom 4 east wall -Upload third party pier inspection for back deck -Upload type of fastener used for back deck post to beam connection -Install anchor bolt in bottom sole plate in basement next to uninstalled sliding patio door -Add missing 3 studs under Ibeam in basement between patio door and window and support the header on the west side under the same Ibeam -Install anchor bolts in the middle 1/3 of sole plate in basement east wall
Miscellaneous Correction
Corrective Action Required
11/07/2024
3929 SW Flintrock All rough (2) Upload third party pier inspection for back deck Add missing 3 studs under Ibeam in basement between patio door and window and support the header on the west side under the same Ibeam
Piers/Caissons Inspection - Residential Passed 11/12/2024 11/12/2024
Miscellaneous Correction
Resolved
11/12/2024
Footing piers passed by a third party
All Rough Inspection - Residential Passed 11/12/2024 11/12/2024 11/12/2024
Miscellaneous Correction
Resolved
11/12/2024
3929 SW Flintrock All rough (2) Upload third party pier inspection for back deck Add missing 3 studs under Ibeam in basement between patio door and window and support the header on the west side under the same Ibeam
Driveway Inspection Partial 2/27/2025 2/27/2025 02/27/2025
Misc
Informational
02/27/2025
2-27-25 Dustin A, Dw is formed and compacted. Approved to pour
Driveway Inspection Failed 3/6/2025 3/6/2025 03/06/2025
Misc
Informational
02/27/2025
2-27-25 Dustin A, Dw is formed and compacted. Approved to pour 3-6-25 Jamie S, DW slopes are within city compliance, forms need to be removed before approval. Call in driveway inspection back in once forms are pulled.
Sidewalk Inspection Partial 03/11/2025
Misc
Informational
03/11/2025
3-11-25 RH. Sidewalk was formed up and approved to pour. Contractor was reminded no picture framing the sidewalk, to use white cure, and place expansion joint at approach and around storm box in the sidewalk.
Driveway Inspection Failed 3/20/2025 3/20/2025 03/20/2025
Misc
Informational
03/06/2025
2-27-25 Dustin A, Dw is formed and compacted. Approved to pour 3-6-25 Jamie S, DW slopes are within city compliance, forms need to be removed before approval. Call in driveway inspection back in once forms are pulled. 3-20-25 Jamie S, DW slopes are within city compliance, forms need to be removed before approval. Call in driveway inspection back in once forms are pulled.
Sidewalk Inspection Failed 3/20/2025 3/20/2025 03/20/2025
Misc
Informational
03/11/2025
3-11-25 RH. Sidewalk was formed up and approved to pour. Contractor was reminded no picture framing the sidewalk, to use white cure, and place expansion joint at approach and around storm box in the sidewalk. Jamie S, SW slopes are within city compliance, forms need to be removed before approval. Call in sidewalk inspection back in once forms are pulled.
Driveway Inspection Passed 3/24/2025 3/24/2025 03/24/2025
Misc
Informational
03/20/2025
2-27-25 Dustin A, Dw is formed and compacted. Approved to pour 3-6-25 Jamie S, DW slopes are within city compliance, forms need to be removed before approval. Call in driveway inspection back in once forms are pulled. 3-20-25 Jamie S, DW slopes are within city compliance, forms need to be removed before approval. Call in driveway inspection back in once forms are pulled. 3-24-25 Dustin A, Forms Have been pulled. Pass
Sidewalk Inspection Passed 3/24/2025 3/24/2025 03/24/2025
Misc
Informational
03/20/2025
3-11-25 RH. Sidewalk was formed up and approved to pour. Contractor was reminded no picture framing the sidewalk, to use white cure, and place expansion joint at approach and around storm box in the sidewalk. Jamie S, SW slopes are within city compliance, forms need to be removed before approval. Call in sidewalk inspection back in once forms are pulled. 3-24-25 Dustin A, Forms have been pulled
Plot Plan Inspection Failed 4/8/2025 04/08/2025
Misc
Corrective Action Required
04/08/2025
The address incorrect and inspection denied
Erosion Control Inspection Residential Passed 4/10/2025 04/10/2025
Miscellaneous Correction
Resolved
04/10/2025
Erosion control measures are in place and must be maintained until CofO
Plot Plan Inspection Passed 4/10/2025 04/10/2025
Misc
Resolved
04/10/2025
The address incorrect and inspection denied
Occupancy Inspection - Codes Residential Failed 4/10/2025 4/10/2025 04/10/2025
Misc
Corrective Action Required
04/10/2025
3929 lower water meter pit and meter to grade Paint and support black pipe gas line under deck Provide (2) 1/2” through bolts at each post to beam connections All exterior receptacles to be the weather resistant type Obtain an irrigation permit Outlet at bar not to be more than 24” horizontally from sink edge Lightning 8’ and below must not be open bulb per security ordinance at back sliding door Remove silt fence back of lot master bathroom outlet meeds switch plate Basement bathroom needs switch plate Open outlet in basement South bedroom closet
Occupancy Inspection - Codes Residential Failed 4/17/2025 4/17/2025 04/17/2025
Misc
Corrective Action Required
04/10/2025
3929 Provide (2) 1/2” through bolts at each post to beam connections
Occupancy Inspection - Codes Residential Full C of O 4/17/2025 04/17/2025
Misc
Resolved
04/17/2025
3929 Provide (2) 1/2” through bolts at each post to beam connections
Documents & Images
Date Uploaded File Type Document Name
05/19/2024 LOT 173 FINAL SURVEY
05/19/2024 NPV173 SPEC - Sealed Plans (May 17, 2024)
05/19/2024 Application Form Permit page 1
05/19/2024 Application Form Permit Page 2
05/19/2024 Application Form PErmit page 3
05/19/2024 Application Form Permit Page 4
05/19/2024 Application Form Permit Page 5
05/19/2024 Application Form Permit Page 6
05/20/2024 Approved Plans APPROVED PLANS
05/20/2024 Plot Plan APPROVED PLOT PLAN
05/22/2024 Permit Codes Residential Plan Review
05/28/2024 Permit DS Building Permit
05/28/2024 Receipt Receipt for transaction:2024-003975
07/01/2024 3929 SW FLINTROCK DR FTG INSP
07/02/2024 Letter INSPECTION SUMMARY
07/02/2024 Letter INSPECTION SUMMARY
07/05/2024 Letter INSPECTION SUMMARY
07/05/2024 Letter INSPECTION SUMMARY
07/08/2024 DW PIER PLAN Lot 173 Napa Valley 3929 SW Flintlock Dr 6-17-24
07/08/2024 DW SOIL REPORT Lot 173 Napa Valley 3929 SW Flintlock Dr 6-19-24 (1)
07/08/2024 Letter INSPECTION SUMMARY
07/08/2024 Letter INSPECTION SUMMARY
07/08/2024 Letter INSPECTION SUMMARY
07/08/2024 Letter INSPECTION SUMMARY
07/10/2024 Letter INSPECTION SUMMARY
07/10/2024 Letter INSPECTION SUMMARY
08/26/2024 Letter INSPECTION SUMMARY
10/16/2024 Letter INSPECTION SUMMARY
10/16/2024 Letter INSPECTION SUMMARY
10/16/2024 Letter INSPECTION SUMMARY
10/16/2024 Letter INSPECTION SUMMARY
10/30/2024 Engineer Report/Study Schedule 40 column letter
11/07/2024 Letter INSPECTION SUMMARY
11/07/2024 Engineer Report/Study ENGINEER PIER REPORT
11/12/2024 Letter INSPECTION SUMMARY
11/12/2024 Letter INSPECTION SUMMARY
02/27/2025 Letter INSPECTION SUMMARY
02/27/2025 Letter INSPECTION SUMMARY
03/06/2025 Letter INSPECTION SUMMARY
03/11/2025 Letter INSPECTION SUMMARY
03/20/2025 Letter INSPECTION SUMMARY
03/20/2025 Letter INSPECTION SUMMARY
03/24/2025 Letter INSPECTION SUMMARY
03/24/2025 Letter INSPECTION SUMMARY
04/07/2025 Plot Plan APPROVED AS GRADED PLOT PLAN
04/08/2025 Letter INSPECTION SUMMARY
04/10/2025 Letter INSPECTION SUMMARY
04/10/2025 Letter INSPECTION SUMMARY
04/10/2025 Letter INSPECTION SUMMARY
04/17/2025 Letter INSPECTION SUMMARY
04/17/2025 Letter Codes Final Certificate of Occupancy
04/17/2025 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home