Permit Application Status

PRRES20242339


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20242339
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. PARTIALLY COVERED PATIO.
05/08/2024
05/21/2024
11/13/2024
10/25/2024
Locations
Contacts
ELEVATE DESIGN & BUILD LLC, Address:350 SW LONGVIEW BLVD, Phone:(816) 622-8826  
Elevate Design + Build , Address:350 Longview Blvd.   
Sara Ladd, Address:350 SW Longview Blvd, Phone:(816) 325-3382  
Bill Seachrest, Address:350 SW Longview Blvd, Phone:(816) 786-8876  
FIVE STAR MECHANICAL CONTRACT INC, Address:P O BOX 11964, Phone:(816) 358-4444  
ELECTRICAL CONNECTIONS, Address:20112 HOPS CREEK DR, Phone:(816) 838-6946  
S&B Plumbing, Inc., Address:PO Box 101, Phone:(913) 850-3445  
BILL@ELEVATEDESIGNBUILDKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 05/21/2024
8350015-Water Meter Fee $680.46 $680.46 Paid 05/21/2024
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 05/21/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 05/21/2024
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 05/21/2024
9110078-Valuation Fee New Single Family $1,160.99 $1,160.99 Paid 05/21/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/30/2024 (1:00) 5/30/2024 05/30/2024
Miscellaneous Correction
Informational
05/30/2024
-No exterior piers were present at the time of footing inspection -UFER is located in the basement utility room along the North wall
Erosion Control Inspection Residential Partial 06/03/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/03/2024
6-3-24 Dustin A, EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Restroom needs to be removed off of storm drain
Erosion Control Inspection Residential Passed 6/5/2024 6/5/2024 06/05/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/03/2024
6-3-24 Dustin A, EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Restroom needs to be removed off of storm drain 6-5-24 Dustin A, Restroom has been moved
Underslab Plumbing Inspection - Residential Failed 6/12/2024 06/12/2024
Misc
Corrective Action Required
06/12/2024
Provide back fill around foundation for inspection
Sewer Service Inspection - R Passed 6/13/2024 (9:45) 6/13/2024 06/13/2024
Water Service Inspection - R Partial 6/13/2024 6/13/2024 06/13/2024
Misc
Informational
06/13/2024
Pex and copper ran from foundation to pit
Erosion Control Inspection Residential Partial 6/14/2024 06/14/2024
Misc
Corrective Action Required
06/14/2024
- OK AT TIME OF INSPECTION
Underslab Plumbing Inspection - Residential Passed 6/14/2024 6/14/2024 06/14/2024
Misc
Corrective Action Required
06/12/2024
Provide back fill around foundation for inspection
Water Service Inspection - R Passed 6/14/2024 06/14/2024
Misc
Resolved
06/14/2024
All Rough Inspection - Residential Failed 7/10/2024 7/10/2024 07/10/2024
Misc
Corrective Action Required
07/10/2024
Garage portal okay to cover Rear cspf sheathing breakers not in middle 24” of portal leg.
Gas Service Inspection - Residential Failed 8/2/2024 8/2/2024 08/02/2024
Misc
Corrective Action Required
08/02/2024
- No pressure on gauge
Erosion Control Inspection Residential Failed 8/2/2024 08/02/2024
Misc
Corrective Action Required
08/02/2024
- REPAIR SILT FENCE
All Rough Inspection - Residential Failed 8/2/2024 8/2/2024 08/02/2024
Misc
Resolved
08/02/2024
Garage portal okay to cover Rear cspf sheathing breakers not in middle 24” of portal leg.
Misc
Corrective Action Required
08/02/2024
2614 SW Barelyfield dr Fb = Fire block or draft stop - Fb top plate penetrations at closest and switch in bedroom 2 - In bedroom 2 nail exterior stud corners to code - Solid block sheeting break at South side of living room window - Provide anchor bolt at plate break at exterior wall of single bay garage - Not able to inspect framing of patio cover ( closed up) - No pressure on gauge for gas piping
Electrical Service Inspection Failed 8/2/2024 8/2/2024 08/02/2024
Misc
Corrective Action Required
08/02/2024
- appears to be set up as main panel, not Sub
All Rough Inspection - Residential Passed 8/5/2024 8/5/2024 08/05/2024
Misc
Resolved
08/05/2024
2614 SW Barelyfield dr Fb = Fire block or draft stop - Fb top plate penetrations at closest and switch in bedroom 2 - In bedroom 2 nail exterior stud corners to code - Solid block sheeting break at South side of living room window - Provide anchor bolt at plate break at exterior wall of single bay garage - Not able to inspect framing of patio cover ( closed up) - No pressure on gauge for gas piping
Electrical Service Inspection Passed 8/6/2024 8/6/2024 08/06/2024
Misc
Resolved
08/06/2024
- appears to be set up as main panel, not Sub
Gas Service Inspection - Residential Passed 8/6/2024 8/6/2024 08/06/2024
Misc
Resolved
08/06/2024
- No pressure on gauge
Driveway Inspection Partial 8/15/2024 8/15/2024 08/15/2024
Misc
Informational
08/15/2024
8-15-24 Dustin A, Dw is formed and aggregate is compacted. Approved to pour
Driveway Inspection Passed 8/27/2024 8/27/2024 08/26/2024
Misc
Informational
08/15/2024
8-15-24 Dustin A, Dw is formed and aggregate is compacted. Approved to pour 8-26-24 Dustin A, DW is poured to city specs. passed
Plot Plan Inspection Passed 10/11/2024 10/11/2024
Erosion Control Inspection Residential Passed 10/25/2024 10/23/2024
Misc
Resolved
10/23/2024
- REPAIR SILT FENCE
Occupancy Inspection - Codes Residential Failed 10/23/2024 10/23/2024 10/23/2024
Misc
Corrective Action Required
10/23/2024
-spark rings at kitchen back splash outlets -missing AFCI protection of multiple circuits see code section E3902.16 -label all non gfci outlets in unfinished spaces
Occupancy Inspection - Codes Residential Full C of O 10/25/2024 10/25/2024 10/25/2024
Misc
Resolved
10/25/2024
-spark rings at kitchen back splash outlets -missing AFCI protection of multiple circuits see code section E3902.16 -label all non gfci outlets in unfinished spaces
Documents & Images
Date Uploaded File Type Document Name
05/08/2024 License_Tax_Application
05/08/2024 LS_tax_signed
05/14/2024 Residental Permit Application_1
05/15/2024 Permit Codes Residential Plan Review
05/15/2024 Permit Codes Residential Plan Review
05/16/2024 24-5-16-Review Comment Response-REV1
05/17/2024 Permit Codes Residential Plan Review
05/17/2024 Permit Codes Residential Plan Review
05/17/2024 24-5-17-Residential Plan Review2
05/17/2024 Approved Plans APPROVED PLANS
05/17/2024 Plot Plan APPROVED PLOT PLAN
05/17/2024 Permit Codes Residential Plan Review
05/17/2024 Permit Codes Residential Plan Review
05/21/2024 Permit DS Building Permit
05/21/2024 Permit DS Building Permit
05/21/2024 Receipt Receipt for transaction:2024-003704
05/30/2024 Letter INSPECTION SUMMARY
05/30/2024 Letter INSPECTION SUMMARY
06/03/2024 Letter INSPECTION SUMMARY
06/03/2024 Letter INSPECTION SUMMARY
06/05/2024 Letter INSPECTION SUMMARY
06/05/2024 Letter INSPECTION SUMMARY
06/11/2024 Letter INSPECTION SUMMARY
06/12/2024 Letter INSPECTION SUMMARY
06/13/2024 Letter INSPECTION SUMMARY
06/13/2024 Letter INSPECTION SUMMARY
06/14/2024 Letter INSPECTION SUMMARY
06/14/2024 Letter INSPECTION SUMMARY
06/14/2024 Letter INSPECTION SUMMARY
07/10/2024 Letter INSPECTION SUMMARY
07/10/2024 Letter INSPECTION SUMMARY
08/02/2024 Letter INSPECTION SUMMARY
08/02/2024 Letter INSPECTION SUMMARY
08/02/2024 Letter INSPECTION SUMMARY
08/02/2024 Letter INSPECTION SUMMARY
08/05/2024 Letter INSPECTION SUMMARY
08/06/2024 Letter INSPECTION SUMMARY
08/06/2024 Letter INSPECTION SUMMARY
08/15/2024 Letter INSPECTION SUMMARY
08/26/2024 Letter INSPECTION SUMMARY
10/10/2024 As Graded PP-24-10-10-HF171
10/10/2024 Plot Plan approved as graded plot plan
10/11/2024 Letter INSPECTION SUMMARY
10/23/2024 Letter INSPECTION SUMMARY
10/23/2024 Letter INSPECTION SUMMARY
10/25/2024 Letter Codes Final Certificate of Occupancy
10/25/2024 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home