Permit Application Status

PRRES20240893


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20240893
Building Permit - Residential
Final Completion
BANNING WILLIAM M & LESLIE
ALTERATION SINGLE FAMILY
basement finish / 825 sq. ft.
02/28/2024
03/14/2024
05/21/2024
Locations
Contacts
DAVE RICHARDS HOMEBUILDING INC, Address:605 SW US HIGHWAY 40 #414, Phone:(816) 365-8034  
DAVE3@DAVERICHARDSHOMES.COM  
BANNING WILLIAM M & LESLIE, Address:4805 NE JAMESTOWN DR  
FIVE STAR MECHANICAL CONTRACT INC, Address:P O BOX 11964, Phone:(816) 358-4444  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 02/28/2024 02/28/2024
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Add/Alter Single Family $165.69 $165.69 Paid 03/14/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
All Rough Inspection - Residential Failed 3/25/2024 3/25/2024 03/25/2024
Misc
Corrective Action Required
03/25/2024
-Fb wall space from soffit space at wet bar location ; fb bathroom sink wall; fb closet wall from joist space -Protect plumbing at wet bar sink -Complete vent bathroom fan to outdoor -Shim gap underneath joists at joist hangers above bathroom **OK TO INSULATE
All Rough Inspection - Residential Passed 3/29/2024 3/29/2024 03/29/2024
Misc
Resolved
03/29/2024
-Shim gap underneath joists at joist hangers above bathroom **OK TO INSULATE
Final Inspection - Residential Failed 5/20/2024 5/20/2024 05/20/2024
Misc
Corrective Action Required
05/20/2024
-Provide AFCI breakers for outlets per NEC 210.12 -The refrigerator receptacle outlet listed within 6 ft of the wet bar sink shall be gfci-protected. Outlet has hot and neutral connectors reversed
Final Inspection - Residential Passed 5/21/2024 5/21/2024 05/21/2024
Misc
Resolved
05/21/2024
-Provide AFCI breakers for outlets per NEC 210.12 -The refrigerator receptacle outlet listed within 6 ft of the wet bar sink shall be gfci-protected. Outlet has hot and neutral connectors reversed
Documents & Images
Date Uploaded File Type Document Name
02/28/2024 Application Form APPLICATION
02/28/2024 Approved Plans APPROVED BASEMENT FINISH
03/14/2024 Permit DS Building Permit
03/14/2024 Receipt Receipt for transaction:2024-001601
03/25/2024 Letter INSPECTION SUMMARY
03/29/2024 Letter INSPECTION SUMMARY
05/20/2024 Letter INSPECTION SUMMARY
05/21/2024 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home