PRRES20240775


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20240775
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE (Continuation of New Residential Build). FINISHED BASEMENT. ROOF TRUSSES. UNCOVERED PATIO. *Foundation up - see PRRES20221208 for Footing, sewer, water, under slab inspections. Andrea Sessler 02/26/2024 3:38 PM STOP WORK ORDER generated on 04/25/2024 12:00 AM by username 'Dustin Agcopra'. STOP WORK ORDER removed on 04/25/2024 12:00 AM by username 'Dustin Agcopra'.
02/22/2024
03/08/2024
08/27/2024
01/24/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
TAYLOR@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $599.05 $599.05 Paid 03/08/2024
$1,198.11
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 08/05/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 01/24/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 4/10/2024 04/10/2024
Miscellaneous Correction
Corrective Action Required
04/10/2024
-Repair or replace silt fence -Spread gravel from street to foundation Full erosion control must be maintained until CofO
Erosion Control Inspection Residential Passed 04/25/2024
Miscellaneous Correction
Corrective Action Required
04/10/2024
-Repair or replace silt fence -Spread gravel from street to foundation Full erosion control must be maintained until CofO
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/25/2024
4-25-24 Dustin A, EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Electrical Service Inspection Passed 5/8/2024 5/8/2024 05/08/2024
Gas Service Inspection - Residential Passed 5/8/2024 5/8/2024 05/08/2024
Erosion Control Inspection Residential Partial 5/8/2024 05/08/2024
Miscellaneous Correction
Resolved
05/08/2024
-Repair or replace silt fence -Spread gravel from street to foundation Full erosion control must be maintained until CofO
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
05/08/2024
4-25-24 Dustin A, EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Miscellaneous Correction
Informational
05/08/2024
Erosion control is in place and must be maintained until CofO
All Rough Inspection - Residential Failed 5/8/2024 5/8/2024 05/08/2024
Miscellaneous Correction
Resolved
05/08/2024
3521 SE Corbin. All rough Exterior garage portal is not nailed to the top plate Interior garage portal sole plate needs 2 hold down bolts installed Garage anchor bolts need to be in the middle 1/3 of the sole plate Some solid blocking is missing above Ibeam in basement Stair stringers must be supported on platforms and 2x10’s at least by 1 1/2 inches Nail basement corners to code Front porch ceiling is covered and can not be inspected Truss tie down screws are missing in the front entry Two truss joist hangers are missing nails on the great room Nail great room S/W corner to code Nail all corners to code Stud shoes in bathroom 1 is missing a nails Fire block top of chase in bathroom 1 Protect all mechanical pipes through top and bottom plate by extending protection plate 2 inches above bottom plate and 2 inches below top plate IRC 1308.2.1
Miscellaneous Correction
Corrective Action Required
05/08/2024
SE Corbin. All rough Exterior garage portal is not nailed to the top plate Interior garage portal sole plate needs 2 hold down bolts installed Garage anchor bolts need to be in the middle 1/3 of the sole plate Some solid blocking is missing above Ibeam in basement Stair stringers must be supported on platforms and 2x10’s at least by 1 1/2 inches Nail basement corners to code Front porch ceiling is covered and can not be inspected Truss tie down screws are missing in the front entry Two truss joist hangers are missing nails on the great room Nail great room S/W corner to code Nail all corners to code Stud shoes in bathroom 1 is missing a nails Fire block top of chase in bathroom 1 Protect all mechanical pipes through top and bottom plate by extending protection plate 2 inches above bottom plate and 2 inches below top plate IRC 1308.2.1 GT H6 straps are not installed
All Rough Inspection - Residential Failed 5/13/2024 5/13/2024 05/13/2024
Miscellaneous Correction
Partial Correction
05/13/2024
3521 SE Corbin. All rough Exterior garage portal is not nailed to the top plate Stair stringers must be supported on platforms and 2x10’s at least by 1 1/2 inches
All Rough Inspection - Residential Passed 5/14/2024 5/14/2024 05/14/2024
Miscellaneous Correction
Resolved
05/14/2024
3521 SE Corbin. All rough Exterior garage portal is not nailed to the top plate Stair stringers must be supported on platforms and 2x10’s at least by 1 1/2 inches
Driveway Inspection Partial 6/25/2024 6/25/2024 06/25/2024
Misc
Informational
06/25/2024
6-25-24 PS Driveway approach pre pour, forms in place, aggregate compacted approved to pour
Sidewalk Inspection Partial 6/25/2024 6/25/2024 06/25/2024
Misc
Informational
06/25/2024
6-25-24 PS Sidewalk pre pour, forms in place, aggregate compacted, approved to pour
Driveway Inspection Passed 7/2/2024 7/2/2024 07/02/2024
Misc
Informational
06/25/2024
6-25-24 PS Driveway approach pre pour, forms in place, aggregate compacted approved to pour 7-2-24 PS Driveway approach meets ADA and LS specs
Sidewalk Inspection Passed 7/2/2024 7/2/2024 07/02/2024
Misc
Informational
06/25/2024
6-25-24 PS Sidewalk pre pour, forms in place, aggregate compacted, approved to pour 7-2-24 PS Sidewalk meets LS and ADA specs
Erosion Control Inspection Residential Partial 7/19/2024 07/19/2024
Miscellaneous Correction
Resolved
07/19/2024
Erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Informational
07/19/2024
Erosion control is in place and must be maintained until CofO
Piers/Caissons Inspection - Residential Passed 7/19/2024 07/19/2024
Occupancy Inspection - Codes Residential Failed 8/1/2024 8/1/2024 08/01/2024
Misc
Corrective Action Required
08/01/2024
-Missing access panel/door for crawlspace beneath stairs -Address/seal hole on exterior siding to the left side of electric meter
Occupancy Inspection - Codes Residential Ready for Temp CO 8/2/2024 8/2/2024 08/02/2024
Misc
Resolved
08/02/2024
Misc
Informational
08/02/2024
Note: Foundation up - see PRRES20221208 for Footing, sewer, water, and under slab inspections.
Occupancy Inspection - Codes Residential Failed 8/6/2024 08/06/2024
Misc
Informational
08/02/2024
Note: Foundation up - see PRRES20221208 for Footing, sewer, water, and under slab inspections.
Misc
Corrective Action Required
08/06/2024
-Missing sod and splash blocks - Plot plan inspection pending
Erosion Control Inspection Residential Failed 8/16/2024 08/16/2024
Miscellaneous Correction
Resolved
08/16/2024
Erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Corrective Action Required
08/16/2024
Erosion control measures are missing at the front of the lot at the street
Erosion Control Inspection Residential Failed 8/27/2024 08/27/2024
Miscellaneous Correction
Resolved
08/27/2024
Erosion control measures are missing at the front of the lot at the street
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
08/27/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Erosion control measures are missing at the front of the lot at the street
Occupancy Inspection - Codes Residential Ready for Temp CO 8/27/2024 08/27/2024
Misc
Informational
08/06/2024
Note: Foundation up - see PRRES20221208 for Footing, sewer, water, and under slab inspections.
Misc
Resolved
08/27/2024
-Missing sod and splash blocks - Plot plan inspection pending
Miscellaneous Correction
Corrective Action Required
08/27/2024
-Missing sod, splash blocks and sump pump - Plot plan inspection pending Builder sent in a TCO extension request. This is the first extension request on this permit. New TCO expires 09/02/2024
Occupancy Inspection - Codes Residential Failed 9/6/2024 09/06/2024
Misc
Informational
08/27/2024
Note: Foundation up - see PRRES20221208 for Footing, sewer, water, and under slab inspections.
Miscellaneous Correction
Resolved
09/06/2024
-Missing sod, splash blocks and sump pump - Plot plan inspection pending Builder sent in a TCO extension request. This is the first extension request on this permit. New TCO expires 09/02/2024
Miscellaneous Correction
Corrective Action Required
09/06/2024
-Seal gas line penetration at siding -Pay $50 fee associated with this permit Everything has passed
Plot Plan Inspection Passed 9/6/2024 09/06/2024
Erosion Control Inspection Residential Passed 9/6/2024 09/06/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
09/06/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Erosion control measures are missing at the front of the lot at the street
Occupancy Inspection - Codes Residential Full C of O 1/24/2025 01/24/2025
Misc
Resolved
01/24/2025
Note: Foundation up - see PRRES20221208 for Footing, sewer, water, and under slab inspections.
Miscellaneous Correction
Resolved
01/24/2025
-Seal gas line penetration at siding -Pay $50 fee associated with this permit Everything has passed
Documents & Images
Date Uploaded File Type Document Name
02/22/2024 CB #147 - Permit Application
02/29/2024 Plot Plan APPROVED PLOT PLAN
02/29/2024 Permit Codes Residential Plan Review
03/07/2024 COBEY CREEK 147 - FND CLARIFICATION - 240305
03/07/2024 Approved Plans APPROVED PLANS
03/07/2024 Approved Plans APPROVED TRUSS LAYOUT
03/07/2024 Approved Plans APPROVED TRUSS PACKAGE
03/07/2024 Permit Codes Residential Plan Review
03/08/2024 Permit DS Building Permit
03/08/2024 Receipt Receipt for transaction:2024-001445
04/10/2024 Letter INSPECTION SUMMARY
04/25/2024 Letter Stop Work Order
04/25/2024 Letter Stop Work Order
04/25/2024 Letter INSPECTION SUMMARY
05/08/2024 Letter INSPECTION SUMMARY
05/08/2024 Letter INSPECTION SUMMARY
05/08/2024 Letter INSPECTION SUMMARY
05/08/2024 Letter INSPECTION SUMMARY
05/08/2024 Letter INSPECTION SUMMARY
05/13/2024 Letter INSPECTION SUMMARY
05/14/2024 Letter INSPECTION SUMMARY
06/25/2024 Letter INSPECTION SUMMARY
06/25/2024 Letter INSPECTION SUMMARY
07/02/2024 Letter INSPECTION SUMMARY
07/02/2024 Letter INSPECTION SUMMARY
07/19/2024 Letter INSPECTION SUMMARY
07/19/2024 Letter INSPECTION SUMMARY
08/01/2024 Letter INSPECTION SUMMARY
08/02/2024 Letter INSPECTION SUMMARY
08/05/2024 Certificate/License Codes Temporary Certificate of Occupancy
08/05/2024 Receipt Receipt for transaction:2024-006522
08/06/2024 Letter INSPECTION SUMMARY
08/16/2024 Letter INSPECTION SUMMARY
08/26/2024 Application Form EXTENSION REQUEST FORM
08/27/2024 Letter INSPECTION SUMMARY
08/27/2024 Letter INSPECTION SUMMARY
09/06/2024 Letter INSPECTION SUMMARY
09/06/2024 Letter INSPECTION SUMMARY
09/06/2024 Letter INSPECTION SUMMARY
01/24/2025 Certificate/License Codes Temporary Certificate of Occupancy
01/24/2025 Receipt Receipt for transaction:2025-000440
01/24/2025 Letter Codes Final Certificate of Occupancy
01/24/2025 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents