NEW SINGLE FAMILY
NEW HOUSE. COVERED DECK. UNFINISHED BASEMENT. STOP WORK ORDER generated on 04/25/2024 12:00 AM by username 'Dustin Agcopra'. STOP WORK ORDER removed on 04/25/2024 12:00 AM by username 'Dustin Agcopra'.
12/04/2023
12/13/2023
06/05/2024
12/10/2024
Locations
Contacts
BELLAH HOMES LLC, Address:P O BOX 346, Phone:(816) 697-2870  
Paul Miller, Address:P.O. Box 346, Phone:(816) 786-5050  
AFC HEATING AND COOLING, Address:824 NW MAIN ST , Phone:(816) 347-8388  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
PAUL@BELLAHHOMES.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $3,760.00 $3,760.00 Paid 12/13/2023
Water Meter Fee $680.46 $680.46 Paid 12/13/2023
Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 12/13/2023
Right of Way Permit Fee $85.00 $85.00 Paid 12/13/2023
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 12/13/2023
Valuation Fee New Single Family $2,163.89 $2,163.89 Paid 12/13/2023
Not Ready Inspection Fee $75.00 $75.00 Paid 06/28/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/26/2024 02/26/2024
Erosion Control Inspection Residential Failed 3/6/2024 03/06/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/06/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - GRAVEL FILTER - REPAIR SILT FENCE
Underslab Plumbing Inspection - Residential Passed 3/6/2024 3/6/2024 03/06/2024
Sewer Service Inspection - R Passed 3/19/2024 3/19/2024 03/19/2024
Water Service Inspection - R Partial 3/19/2024 3/19/2024 03/19/2024
Misc
Partial Correction
03/19/2024
Copper into foundation
Water Service Inspection - R Passed 3/20/2024 3/20/2024 03/20/2024
Misc
Resolved
03/20/2024
Erosion Control Inspection Residential Failed 3/20/2024 03/20/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/06/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - REPAIR SILT FENCE AT DRIVEWAY
Erosion Control Inspection Residential Passed 04/25/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/20/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - REPAIR SILT FENCE AT DRIVEWAY
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/25/2024
4-25-24 Dustin A, EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Erosion Control Inspection Residential Partial 4/26/2024 4/26/2024 04/26/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
04/26/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - REPAIR SILT FENCE AT DRIVEWAY
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
04/26/2024
4-25-24 Dustin A, EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Misc
Corrective Action Required
04/26/2024
-OK AT TIME OF INSPECTION
All Rough Inspection - Residential Not Ready 6/27/2024 6/27/2024 06/27/2024
Misc
Corrective Action Required
06/27/2024
INSPECTION DENIED - NO ADDRESS POSTED - NO GAS LINE, complete all MEP’s - FIRE BLOCKING NOT DONE
Electrical Service Inspection Passed 7/3/2024 7/3/2024 07/03/2024
Gas Service Inspection - Residential Failed 7/3/2024 7/3/2024 07/03/2024
Misc
Corrective Action Required
07/03/2024
- provide bonding for gas piping
Erosion Control Inspection Residential Partial 7/3/2024 07/03/2024
Misc
Resolved
07/03/2024
-OK AT TIME OF INSPECTION
Misc
Corrective Action Required
07/03/2024
- Ok at time of inspection
All Rough Inspection - Residential Failed 7/3/2024 7/3/2024 07/03/2024
Misc
Resolved
07/03/2024
INSPECTION DENIED - NO ADDRESS POSTED - NO GAS LINE, complete all MEP’s - FIRE BLOCKING NOT DONE
Misc
Corrective Action Required
07/03/2024
1113 sw Corinthian ln Fb = Fire block/ draft stop - Fb all top plate penetrations above garage doors - Protect water lines in master shower - Provide window @ master tub - Fb top plate penetrations @ master/bathroom vanity - Provide window @master bedroom - Provide security blocking at all exterior doors - At bottom of stairs to second floor stud missing above not supported below second floor - Address Gap in top plate and less than 24” overlap at top plate Bedroom 3 closet - Address over tapered bottom support of valley rafter @ Bedroom 4 - All steel columns are 3”, plans call for 3 1/2” - Gas piping not bonded
Gas Service Inspection - Residential Passed 7/10/2024 7/10/2024 07/10/2024
Misc
Resolved
07/10/2024
Erosion Control Inspection Residential Failed 7/10/2024 07/10/2024
Misc
Resolved
07/10/2024
- Ok at time of inspection
Misc
Corrective Action Required
07/10/2024
- REMOVE CONSTRUCTION DEBRIS - TRIM OVERGROWN VEGETATION
All Rough Inspection - Residential Failed 7/10/2024 7/10/2024 07/10/2024
Misc
Corrective Action Required
07/03/2024
- Provide window @ master tub - All steel columns are 3”, plans call for 3 1/2” OK TO INSULATE
All Rough Inspection - Residential Passed 7/19/2024 7/19/2024 07/19/2024
Misc
Resolved
07/19/2024
Sidewalk Inspection Partial 8/27/2024 8/27/2024 08/27/2024
Misc
Informational
08/27/2024
8-27-24 DP. SW is formed, aggregate compacted, cross slopes in compliance but conditions can change. Approved to pour.
Erosion Control Inspection Residential Passed 9/3/2024 9/3/2024 09/03/2024
Misc
Corrective Action Required
07/10/2024
- REMOVE CONSTRUCTION DEBRIS - TRIM OVERGROWN VEGETATION
Misc
Informational
09/03/2024
9-3-24 DP. ESC has been installed.
Sidewalk Inspection Partial 9/3/2024 9/3/2024 09/03/2024
Misc
Informational
09/03/2024
8-27-24 DP. SW was formed, aggregate compacted, cross slopes in compliance but conditions can change. Approved to pour. 9-3-24 DP. Forms still on SW. Need to be removed before getting final.
Sidewalk Inspection Partial 9/9/2024 9/9/2024 09/09/2024
Misc
Informational
09/03/2024
8-27-24 DP. SW was formed, aggregate compacted, cross slopes in compliance but conditions can change. Approved to pour. 9-3-24 DP. Forms still on SW. Need to be removed before getting final. 9-9-24 DP. SW Still has forms that need to be removed.
Sidewalk Inspection Passed 9/11/2024 09/11/2024
Misc
Informational
09/09/2024
8-27-24 DP. SW was formed, aggregate compacted, cross slopes in compliance but conditions can change. Approved to pour. 9-3-24 DP. Forms still on SW. Need to be removed before getting final. 9-9-24 DP. SW Still has forms that need to be removed. 9-11-24 DP. Sidwalk's forms have been removed and cross slopes are in compliance. Passed.
Erosion Control Inspection Residential Failed 12/4/2024 12/04/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
12/04/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - PROTECT FRONT OF LOT. EROSION CONTROL TO BE IN PLACE UNTIL SOD IS IN.
Plot Plan Inspection Passed 12/4/2024 12/04/2024
Occupancy Inspection - Codes Residential Failed 12/4/2024 12/4/2024 12/04/2024
Misc
Corrective Action Required
12/04/2024
- final grading and sod - Seal top of electrical meter can and A/C disconnect - Label non- GFCI outlet in garage - Handrail at garage stairs at 40” ( lower to 34-38”) - Provide back flow prevention at spigot basement by main shut off
Erosion Control Inspection Residential Passed 12/10/2024 12/10/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
12/10/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - PROTECT FRONT OF LOT. EROSION CONTROL TO BE IN PLACE UNTIL SOD IS IN.
Occupancy Inspection - Codes Residential Full C of O 12/10/2024 12/10/2024 12/10/2024
Misc
Resolved
12/10/2024
- Provide back flow prevention at spigot basement by main shut off
Documents & Images
Date Uploaded File Type Document Name
12/04/2023 Lot 126 Permit Application
12/04/2023 Lot 126 Tax Application
12/08/2023 Permit Codes Residential Plan Review
12/12/2023 Plot Plan APPROVED PLOT PLAN
12/12/2023 Approved Plans APPROVED PLANS
12/12/2023 Permit Codes Residential Plan Review
12/13/2023 Permit DS Building Permit
12/13/2023 Receipt Receipt for transaction: 2023-009070
02/23/2024 M L Crose 1113 SW Corinthian Ln LSMO Pergola Park Lot 126 3rd Party Footing Inspection Report 2-23-24
02/26/2024 Letter INSPECTION SUMMARY
03/06/2024 Letter INSPECTION SUMMARY
03/06/2024 Letter INSPECTION SUMMARY
03/19/2024 Letter INSPECTION SUMMARY
03/19/2024 Letter INSPECTION SUMMARY
03/20/2024 Letter INSPECTION SUMMARY
03/20/2024 Letter INSPECTION SUMMARY
04/25/2024 Letter Stop Work Order
04/25/2024 Letter Stop Work Order
04/25/2024 Letter INSPECTION SUMMARY
04/26/2024 Letter INSPECTION SUMMARY
06/27/2024 Letter INSPECTION SUMMARY
06/28/2024 Receipt Receipt for transaction:2024-005315
07/03/2024 Letter INSPECTION SUMMARY
07/03/2024 Letter INSPECTION SUMMARY
07/03/2024 Letter INSPECTION SUMMARY
07/03/2024 Letter INSPECTION SUMMARY
07/10/2024 Letter INSPECTION SUMMARY
07/10/2024 Letter INSPECTION SUMMARY
07/10/2024 Letter INSPECTION SUMMARY
07/19/2024 Letter INSPECTION SUMMARY
08/27/2024 Letter INSPECTION SUMMARY
09/03/2024 Letter INSPECTION SUMMARY
09/03/2024 Letter INSPECTION SUMMARY
09/09/2024 Letter INSPECTION SUMMARY
09/11/2024 Letter INSPECTION SUMMARY
12/04/2024 Letter INSPECTION SUMMARY
12/04/2024 Letter INSPECTION SUMMARY
12/04/2024 Letter INSPECTION SUMMARY
12/04/2024 Letter INSPECTION SUMMARY
12/10/2024 Letter Codes Final Certificate of Occupancy
12/10/2024 Letter Field Certificate of Occupancy
12/10/2024 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home