Permit Application Status

PRRES20236250


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20236250
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. WALKOUT BASEMENT. COVERED DECK. STOP WORK ORDER generated on 02/06/2024 12:00 AM by username 'Robb Popp'. STOP WORK ORDER removed on 02/15/2024 12:00 AM by username 'Robb Popp'.
11/28/2023
12/08/2023
05/28/2024
08/23/2024
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
Ashley Kirby, Address:5207 NW Crooked Rd, Phone:(816) 969-9010  
HARRINGTON BROTHERS HEATING & COOLING, Address:15630 S KEELER ST, Phone:(913) 422-5444  
ELECTRICAL INVESTMENTS, Address:8014 REEDER ST, Phone:(816) 210-1597  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
whitney@newmarkhomeskc.com  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $3,760.00 $3,760.00 Paid 12/08/2023
Water Meter Fee $680.46 $680.46 Paid 12/08/2023
Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 12/08/2023
Right of Way Permit Fee $85.00 $85.00 Paid 12/08/2023
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 12/08/2023
Valuation Fee New Single Family $2,437.79 $2,437.79 Paid 12/08/2023
Temporary Occupancy Fee $50.00 $50.00 Paid 08/13/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 1/30/2024 1/30/2024 01/30/2024
Misc
Corrective Action Required
01/30/2024
-Have engineer address pier pads in rec room not fully bearing on soil. Pads are formed over the excavated bank. This footing is not approved to pour
Erosion Control Inspection Residential Partial 1/30/2024 01/30/2024
Misc
Corrective Action Required
01/30/2024
BMP in compliance at time of inspection
Miscellaneous Inspection Failed 1/30/2024 01/30/2024
Misc
Corrective Action Required
01/30/2024
Post site address
Footing Inspection - Residential Failed - Stop Work 2/6/2024 02/06/2024
Misc
Corrective Action Required
01/30/2024
1/31/24 -Have engineer address pier pads in rec room not fully bearing on soil. Pads are formed over the excavated bank. This footing is not approved to pour
Misc
Corrective Action Required
02/06/2024
2/6/24 -FOOTING AND FOUNDATION WALLS POURED WITHOUT INSPECTION. NO RECORD OF 3RD PARTY INSPECTION ON FILE. NO DOCUMENTATION OF ENGINEERED CORRECTION OR APPROVAL FOR UNDERMINED PIER PADS. SEE PHOTO UPLOADED ON PORTAL.
Erosion Control Inspection Residential Failed 8/6/2024 02/06/2024
Misc
Resolved
02/06/2024
BMP in compliance at time of inspection
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/06/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. *2/6/24 -Install erosion control methods at spoils pile and disturbed soil at adjacent lot
Erosion Control Inspection Residential Passed 2/15/2024 02/15/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
02/15/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. *2/6/24 -Install erosion control methods at spoils pile and disturbed soil at adjacent lot
Misc
Informational
02/15/2024
Erosion control in compliance at time of inspection
Underslab Plumbing Inspection - Residential Passed 2/16/2024 2/16/2024 02/16/2024
Erosion Control Inspection Residential Failed 3/21/2024 03/21/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/21/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Restore silt fence at side of lot and remove trash from site
Sewer Service Inspection - R Passed 4/4/2024 4/4/2024 04/04/2024
Water Service Inspection - R Passed 4/5/2024 04/05/2024
Footing Inspection - Residential Passed 4/29/2024 04/29/2024
Misc
Resolved
04/29/2024
1/31/24 -Have engineer address pier pads in rec room not fully bearing on soil. Pads are formed over the excavated bank. This footing is not approved to pour
Misc
Resolved
04/29/2024
2/6/24 -FOOTING AND FOUNDATION WALLS POURED WITHOUT INSPECTION. NO RECORD OF 3RD PARTY INSPECTION ON FILE. NO DOCUMENTATION OF ENGINEERED CORRECTION OR APPROVAL FOR UNDERMINED PIER PADS. SEE PHOTO UPLOADED ON PORTAL.
Misc
Corrective Action Required
04/29/2024
-Footing and piers approved by Al Hermans on 1/30/24
Electrical Service Inspection Passed 4/29/2024 4/29/2024 04/29/2024
Gas Service Inspection - Residential Passed 4/29/2024 4/29/2024 04/29/2024
All Rough Inspection - Residential Failed 4/29/2024 4/29/2024 04/29/2024
Misc
Corrective Action Required
04/29/2024
-Anchor bolt missing at garage NW corner -Fire blocking missing at coat closet ceiling -Master stool fan vent kinked
All Rough Inspection - Residential Passed 5/1/2024 5/1/2024 05/01/2024
Misc
Resolved
05/01/2024
Driveway Inspection Partial 5/15/2024 5/15/2024 05/15/2024
Misc
Informational
05/15/2024
5-15-24 DP. DW was formed, aggregate compacted, told to pay attention to rain incoming. Approved to pour.
Driveway Inspection Passed 5/22/2024 5/22/2024 05/22/2024
Misc
Informational
05/15/2024
5-15-24 DP. DW was formed, aggregate compacted, told to pay attention to rain incoming. Approved to pour. 5-22-24 Dustin A, DW is poured to city specs. Passed
Erosion Control Inspection Residential Failed 6/20/2024 06/20/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/21/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -RESTORE SILT FENCE
Erosion Control Inspection Residential Failed 8/6/2024 8/6/2024 08/06/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
08/06/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -RESTORE SILT FENCE
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/06/2024
**8/6/24 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. NO FURTHER INSPECTIONS UNTIL IN COMPLIANCE
Occupancy Inspection - Codes Residential Failed 8/6/2024 8/6/2024 08/06/2024
Misc
Corrective Action Required
08/06/2024
-Complete final grade, sod, gutters, downspouts and splash blocks
Occupancy Inspection - Codes Residential Ready for Temp CO 8/14/2024 08/13/2024
Misc
Corrective Action Required
08/06/2024
-Complete final grade, sod, gutters, downspouts and splash blocks
Erosion Control Inspection Residential Passed 08/23/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
08/23/2024
**8/6/24 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. NO FURTHER INSPECTIONS UNTIL IN COMPLIANCE
Plot Plan Inspection Passed 08/23/2024
Occupancy Inspection - Codes Residential Full C of O 8/23/2024 08/23/2024
Misc
Resolved
08/23/2024
-Complete final grade, sod, gutters, downspouts and splash blocks
Documents & Images
Date Uploaded File Type Document Name
11/28/2023 WR176 Permit Application
11/30/2023 Permit Codes Residential Plan Review
11/30/2023 Plot Plan APPROVED PLOT PLAN
12/06/2023 Approved Plans APPROVED PLANS
12/06/2023 Permit Codes Residential Plan Review
12/08/2023 Permit DS Building Permit
12/08/2023 Receipt Receipt for transaction:2023-008976
01/30/2024 Letter INSPECTION SUMMARY
01/30/2024 Letter INSPECTION SUMMARY
01/30/2024 Letter INSPECTION SUMMARY
02/06/2024 Undermined pier pads
02/06/2024 Letter Stop Work Order
02/06/2024 Letter INSPECTION SUMMARY
02/07/2024 2083 OBRIEN RD FOOTING LETTER
02/07/2024 2083 OBRIEN RD FTG INSP
02/15/2024 Letter INSPECTION SUMMARY
02/16/2024 Letter INSPECTION SUMMARY
02/22/2024 Engineer Report/Study ALL SLAB & DECK PIER INSP_2024-02-20
03/21/2024 Letter INSPECTION SUMMARY
04/04/2024 Letter INSPECTION SUMMARY
04/05/2024 Letter INSPECTION SUMMARY
04/29/2024 Letter INSPECTION SUMMARY
04/29/2024 Letter INSPECTION SUMMARY
04/29/2024 Letter INSPECTION SUMMARY
04/29/2024 Letter INSPECTION SUMMARY
05/01/2024 Letter INSPECTION SUMMARY
05/15/2024 Letter INSPECTION SUMMARY
05/22/2024 Letter INSPECTION SUMMARY
06/20/2024 Letter INSPECTION SUMMARY
08/06/2024 Letter INSPECTION SUMMARY
08/06/2024 Letter INSPECTION SUMMARY
08/13/2024 Letter INSPECTION SUMMARY
08/13/2024 Certificate/License Codes Temporary Certificate of Occupancy
08/13/2024 Receipt Receipt for transaction:2024-006821
08/23/2024 Letter INSPECTION SUMMARY
08/23/2024 Letter INSPECTION SUMMARY
08/23/2024 Letter Codes Final Certificate of Occupancy
08/23/2024 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: