Permit Application Status

PRRES20232880


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20232880
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. COVERED DECK. ROOF TRUSSES.
06/19/2023
06/28/2023
12/24/2023
04/10/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
BILLQ@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $3,730.00 $3,730.00 Paid 06/28/2023
Water Meter Fee $550.50 $550.50 Paid 06/28/2023
Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 06/28/2023
Right of Way Permit Fee $85.00 $85.00 Paid 06/28/2023
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 06/28/2023
Valuation Fee New Single Family $1,291.65 $1,291.65 Paid 06/28/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/6/2023 7/6/2023 07/06/2023
Miscellaneous Correction
Informational
07/06/2023
Three piers for the back deck were set to pour at the same time as the footing
Piers/Caissons Inspection - Residential Passed 7/6/2023 07/06/2023
Miscellaneous Correction
Informational
07/06/2023
Three deck piers were set to pour at the same time as the footing.
Sewer Service Inspection - R Passed 7/20/2023 (11:00) 7/20/2023 07/20/2023
Water Service Inspection - R Passed 7/20/2023 (1:45) 7/20/2023 07/20/2023
Erosion Control Inspection Residential Failed 7/26/2023 07/26/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/26/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Underslab Plumbing Inspection - Residential Passed 7/26/2023 7/26/2023 07/26/2023
Gas Service Inspection - Residential Failed 1/5/2024 1/5/2024 01/05/2024
Misc
Corrective Action Required
01/05/2024
-provide minimum 5min psi a gas gauge -complete gas line install at fireplace
Electrical Service Inspection Passed 1/5/2024 1/5/2024 01/05/2024
All Rough Inspection - Residential Failed 1/5/2024 1/5/2024 01/05/2024
Misc
Corrective Action Required
01/05/2024
-anchor bolts to be in the middle 1/3 of sill plate. -anchor bolts to be within 12” of plate breaks but not closer that 7x the diameter of the bolt -seal top plate penetration at top of stairs and foyer -complete gas line installation -uncover cover front porch and deck for inspection -fire block beam ends in basement -seal penetration in 10’ fire blocking in basement E wall -fire block vertically every 10’ horizontally See windows S wall, west basement wall -seal penetrations from wall space to ceiling space multiple throughout basement -for block plumbing into furr dow bed 4 -fireblock bed 4 closet to ceiling space -missing lateral bracing on multiple trusses -trusses on e side of home do not match truss plans. Check all trusses to ensure correct placement
Erosion Control Inspection Residential Failed 1/5/2024 01/05/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/26/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
01/05/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Gas Service Inspection - Residential Passed 1/11/2024 1/11/2024 01/11/2024
Misc
Resolved
01/11/2024
-provide minimum 5min psi a gas gauge -complete gas line install at fireplace
All Rough Inspection - Residential Passed 1/11/2024 1/11/2024 01/11/2024
Misc
Resolved
01/11/2024
-anchor bolts to be in the middle 1/3 of sill plate. -anchor bolts to be within 12” of plate breaks but not closer that 7x the diameter of the bolt -seal top plate penetration at top of stairs and foyer -complete gas line installation -uncover cover front porch and deck for inspection -fire block beam ends in basement -seal penetration in 10’ fire blocking in basement E wall -fire block vertically every 10’ horizontally See windows S wall, west basement wall -seal penetrations from wall space to ceiling space multiple throughout basement -for block plumbing into furr dow bed 4 -fireblock bed 4 closet to ceiling space -missing lateral bracing on multiple trusses -trusses on e side of home do not match truss plans. Check all trusses to ensure correct placement
Driveway Inspection Partial 2/1/2024 2/1/2024 02/01/2024
Misc
Informational
02/01/2024
2-1-24 Dustin A, DW is formed and aggregate ic compacted . Approved to pour
Driveway Inspection Passed 2/8/2024 2/8/2024 02/05/2024
Misc
Informational
02/01/2024
2-1-24 Dustin A, DW is formed and aggregate ic compacted . Approved to pour 2-5-24 Dustin A, DW is poured. Forms are pulled. Passed
Erosion Control Inspection Residential Failed 2/7/2024 02/07/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
01/05/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
02/07/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/07/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN AND REPLACE SILT FENCE AT FRONT OF LOT.
Occupancy Inspection - Codes Residential Failed 4/2/2024 4/2/2024 04/02/2024
Misc
Corrective Action Required
04/02/2024
No erosion control in place inspection denied
Erosion Control Inspection Residential Failed 4/2/2024 04/02/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
04/02/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM2 ESC DEFICIENT INSTALLATION
Resolved
04/02/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN AND REPLACE SILT FENCE AT FRONT OF LOT.
DCM5 ESC INSP DENIED
Corrective Action Required
04/02/2024
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/02/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Failed 4/3/2024 4/3/2024 04/03/2024
Misc
Resolved
04/03/2024
No erosion control in place inspection denied
Misc
Corrective Action Required
04/03/2024
-sod -splash blocks and sump pump discharge -provide as graded plot plan -will check water meter at time of sod, meter to be 14”-18” from top of meter to well lid ring -(2) 1/2” through bolts at deck post to beam connections -spark rings at basement wet bar backsplash outlets -
Plot Plan Inspection Passed 04/10/2024
Erosion Control Inspection Residential Passed 04/10/2024
DCM5 ESC INSP DENIED
Resolved
04/10/2024
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
DCM3 ESC REQUIRED 2 DAY
Resolved
04/10/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Full C of O 4/10/2024 4/10/2024 04/10/2024
Misc
Resolved
04/10/2024
-sod -splash blocks and sump pump discharge -provide as graded plot plan -will check water meter at time of sod, meter to be 14”-18” from top of meter to well lid ring -(2) 1/2” through bolts at deck post to beam connections -spark rings at basement wet bar backsplash outlets -
Documents & Images
Date Uploaded File Type Document Name
06/19/2023 H3 #84 - PERMIT APP
06/26/2023 Permit Codes Residential Plan Review
06/27/2023 Permit Codes Residential Plan Review
06/28/2023 Plot Plan APPROVED PLOT PLAN
06/28/2023 Approved Plans APPROVED TRUSS PACKAGE
06/28/2023 Approved Plans APPROVED TRUSS LAYOUT
06/28/2023 Approved Plans APPROVED PLANS
06/28/2023 Permit Codes Residential Plan Review
06/28/2023 Permit DS Building Permit
06/28/2023 Receipt Receipt for transaction:2023-004968
07/06/2023 Letter INSPECTION SUMMARY
07/06/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter INSPECTION SUMMARY
07/26/2023 Letter INSPECTION SUMMARY
07/26/2023 Letter INSPECTION SUMMARY
12/19/2023 Letter Codes 140 Day Letter
01/05/2024 Letter INSPECTION SUMMARY
01/05/2024 Letter INSPECTION SUMMARY
01/05/2024 Letter INSPECTION SUMMARY
01/05/2024 Letter INSPECTION SUMMARY
01/11/2024 Letter INSPECTION SUMMARY
01/11/2024 Letter INSPECTION SUMMARY
02/01/2024 Letter INSPECTION SUMMARY
02/05/2024 Letter INSPECTION SUMMARY
02/07/2024 Letter INSPECTION SUMMARY
04/02/2024 Letter INSPECTION SUMMARY
04/02/2024 Letter INSPECTION SUMMARY
04/03/2024 Letter INSPECTION SUMMARY
04/04/2024 LOT 84 ASBUILT
04/10/2024 Letter INSPECTION SUMMARY
04/10/2024 Letter INSPECTION SUMMARY
04/10/2024 Letter Field Certificate of Occupancy
04/10/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home