Permit Application Status

PRRES20232322


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20232322
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - ROOF TRUSSES
05/23/2023
06/06/2023
11/21/2023
06/27/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
Savanna Scarbo, Address:120 SE 30th st, Phone:(816) 246-6700  
SAVANNA@SUMMITHOMESKC.COM  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
CARUTHERS ELECTRICAL LLC, Address:30905 E TRUMAN RD, Phone:(816) 508-9050  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 06/06/2023
Right of Way Permit Fee $85.00 $85.00 Paid 06/06/2023
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 06/06/2023
Water Tap Fee $3,730.00 $3,730.00 Paid 06/06/2023
Water Meter Fee $550.50 $550.50 Paid 06/06/2023
Valuation Fee New Single Family $1,553.26 $1,553.26 Paid 06/06/2023
Not Ready Inspection Fee $75.00 $75.00 Paid 02/29/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 03/07/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/30/2023 06/30/2023
Miscellaneous Correction
Informational
06/30/2023
Footing was passed by a third party inspector. Piers were not included in footing inspection.
Underslab Plumbing Inspection - Residential Passed 7/13/2023 7/13/2023 07/13/2023
Erosion Control Inspection Residential Partial 7/13/2023 07/13/2023
Miscellaneous Correction
Informational
07/13/2023
Erosion control is in place at the time of under slab plumbing inspection
Sewer Service Inspection - R Passed 7/20/2023 7/20/2023 07/20/2023
Water Service Inspection - R Failed 7/20/2023 7/20/2023 07/20/2023
Miscellaneous Correction
Corrective Action Required
07/20/2023
Water line is not installed at the time it was scheduled for. 07/20/2023. KBEARD 11:22AM
Water Service Inspection - R Passed 7/20/2023 07/20/2023
Miscellaneous Correction
Resolved
07/20/2023
Water line is not installed at the time it was scheduled for. 07/20/2023. KBEARD 11:22AM
Erosion Control Inspection Residential Failed 8/29/2023 08/29/2023
Miscellaneous Correction
Informational
07/13/2023
Erosion control is in place at the time of under slab plumbing inspection
Miscellaneous Correction
Corrective Action Required
08/29/2023
Erosion control is damaged and needs to be repaired. Remove dirt and gravel from the streets. Full erosion control must be maintained until CO
Erosion Control Inspection Residential Failed 11/30/2023 11/30/2023
Miscellaneous Correction
Informational
08/29/2023
Erosion control is in place at the time of under slab plumbing inspection
Miscellaneous Correction
Corrective Action Required
08/29/2023
Erosion control is damaged and needs to be repaired. Remove dirt and gravel from the streets. Full erosion control must be maintained until CO
Miscellaneous Correction
Corrective Action Required
11/30/2023
Some erosion control is damaged or missing. Erosion control must be maintained until CofO. Remove mud and gravel in the street. This is the second notice. No inspections will be completed until full erosion control is in place and streets are cleared. 11/30/23 KBEARD
Erosion Control Inspection Residential Partial 12/13/2023 12/13/2023
Miscellaneous Correction
Informational
11/30/2023
Erosion control is in place at the time of under slab plumbing inspection
Miscellaneous Correction
Resolved
12/13/2023
Erosion control is damaged and needs to be repaired. Remove dirt and gravel from the streets. Full erosion control must be maintained until CO
Miscellaneous Correction
Resolved
12/13/2023
Some erosion control is damaged or missing. Erosion control must be maintained until CofO. Remove mud and gravel in the street. This is the second notice. No inspections will be completed until full erosion control is in place and streets are cleared. 11/30/23 KBEARD
Miscellaneous Correction
Informational
12/13/2023
Erosion control is in place at the time of all rough. Full erosion control must be maintained until CofO
All Rough Inspection - Residential Failed 12/13/2023 12/13/2023 12/13/2023
Miscellaneous Correction
Corrective Action Required
12/13/2023
2133 sw Rutherford. All rough Verify if trusses in garage have adequate support at joist hangers being nailed to sheeting Verify if truss tie down screws in garage are adequate length to penetrate and secure through 3 depths of top plate Fire block in garage at low voltage wire penetrations Strap in needs in the garage top plate at N/E corner Chase top in party needs to be fire blocked at the ceiling Renail double joist hanger at stair landing Strap is needed in top plate at stair landing in corner Attic access requires a minimum of 30 inches of head room Nail N/E corner of bedroom one to code Strap corner of bedroom 1 closet top plate Gas line is not bonded
Electrical Service Inspection Passed 12/13/2023 12/13/2023 12/13/2023
All Rough Inspection - Residential Failed 12/15/2023 12/15/2023 12/15/2023
Miscellaneous Correction
Partial Correction
12/15/2023
2133 sw Rutherford. All rough Verify if trusses in garage have adequate support at joist hangers being nailed to sheeting Verify if truss tie down screws in garage are adequate length to penetrate and secure through 3 depths of top plate Fire block in garage at low voltage wire penetrations Strap in needs in the garage top plate at N/E corner Chase top in party needs to be fire blocked at the ceiling Renail double joist hanger at stair landing Strap is needed in top plate at stair landing in corner Attic access requires a minimum of 30 inches of head room Nail N/E corner of bedroom one to code Strap corner of bedroom 1 closet top plate Gas line is not bonded
Miscellaneous Correction
Corrective Action Required
12/15/2023
2133 sw Rutherford. All rough 2nd inspection -Verify ( engineers letter) if trusses in garage have adequate support at joist hangers being nailed to sheeting -garage attic space is not vented
All Rough Inspection - Residential Not Ready 12/19/2023 12/20/2023 12/20/2023
Miscellaneous Correction
Partial Correction
12/20/2023
2133 sw Rutherford. All rough Verify if trusses in garage have adequate support at joist hangers being nailed to sheeting Verify if truss tie down screws in garage are adequate length to penetrate and secure through 3 depths of top plate Fire block in garage at low voltage wire penetrations Strap in needs in the garage top plate at N/E corner Chase top in party needs to be fire blocked at the ceiling Renail double joist hanger at stair landing Strap is needed in top plate at stair landing in corner Attic access requires a minimum of 30 inches of head room Nail N/E corner of bedroom one to code Strap corner of bedroom 1 closet top plate Gas line is not bonded
Miscellaneous Correction
Corrective Action Required
12/15/2023
2133 sw Rutherford. All rough 2nd inspection -Verify ( engineers letter) if trusses in garage have adequate support at joist hangers being nailed to sheeting -garage attic space is not vented
Miscellaneous Correction
Corrective Action Required
12/20/2023
Garage Attic vents were not cut in at the time of inspection. Not ready for inspection. Walk your properties before scheduling inspections 12/20/23 KBEARD 9:26 AM
Gas Service Inspection - Residential Passed 12/13/2023 12/21/2023 12/21/2023
All Rough Inspection - Residential Passed 12/21/2023 12/21/2023 12/21/2023
Miscellaneous Correction
Resolved
12/21/2023
2133 sw Rutherford. All rough Verify if trusses in garage have adequate support at joist hangers being nailed to sheeting Verify if truss tie down screws in garage are adequate length to penetrate and secure through 3 depths of top plate Fire block in garage at low voltage wire penetrations Strap in needs in the garage top plate at N/E corner Chase top in party needs to be fire blocked at the ceiling Renail double joist hanger at stair landing Strap is needed in top plate at stair landing in corner Attic access requires a minimum of 30 inches of head room Nail N/E corner of bedroom one to code Strap corner of bedroom 1 closet top plate Gas line is not bonded
Miscellaneous Correction
Resolved
12/21/2023
2133 sw Rutherford. All rough 2nd inspection -Verify ( engineers letter) if trusses in garage have adequate support at joist hangers being nailed to sheeting -garage attic space is not vented
Miscellaneous Correction
Resolved
12/21/2023
Garage Attic vents were not cut in at the time of inspection. Not ready for inspection. Walk your properties before scheduling inspections 12/20/23 KBEARD 9:26 AM
Driveway Inspection Partial 2/1/2024 2/1/2024 02/01/2024
Misc
Informational
02/01/2024
2-1-24 Dustin a, Dw is formed and meets city specs, Approved to pour
Driveway Inspection Passed 2/8/2024 2/8/2024 02/05/2024
Misc
Informational
02/01/2024
2-1-24 Dustin a, Dw is formed and meets city specs, Approved to pour 2-5-24 Dustin A, DW is poured. Slopes are in compliance . Passed
Occupancy Inspection - Codes Residential Failed 2/23/2024 2/23/2024 02/23/2024
Miscellaneous Correction
Corrective Action Required
02/23/2024
-All interior inspections have passed -Exterior was not ready and sidewalk must pass before a TCO can be issued
Sidewalk Inspection Partial 02/28/2024
Misc
Informational
02/28/2024
2-28-24 Dustin A, SW's are all formed to city specs. approved to pour
Occupancy Inspection - Codes Residential Failed 2/29/2024 2/29/2024 02/29/2024
Miscellaneous Correction
Corrective Action Required
02/23/2024
-All interior inspections have passed -Exterior was not ready and sidewalk must pass before a TCO can be issued
Misc
Corrective Action Required
02/29/2024
-Must maintain erosion control -Final grade, sod and splash blocks not complete -Missing sump pump extension -Sidewalk still shows as partial
Sidewalk Inspection Passed 3/6/2024 3/6/2024 03/04/2024
Misc
Informational
02/28/2024
2-28-24 Dustin A, SW's are all formed to city specs. approved to pour 3-4-24 Dustin A, sw are poured to city specs. Slopes are in compliance. Passed
Occupancy Inspection - Codes Residential Failed 3/6/2024 3/6/2024 03/06/2024
Miscellaneous Correction
Resolved
03/06/2024
-All interior inspections have passed -Exterior was not ready and sidewalk must pass before a TCO can be issued
Misc
Resolved
03/06/2024
-Must maintain erosion control -Final grade, sod and splash blocks not complete -Missing sump pump extension -Sidewalk still shows as partial
Miscellaneous Correction
Corrective Action Required
03/06/2024
-Must maintain erosion control -Final grade, sod and splash blocks not complete -Missing sump pump extension Inspection for Occupancy failed, if scheduling for TCO, please specify when ordering an inspection
Erosion Control Inspection Residential Failed 3/6/2024 03/06/2024
Miscellaneous Correction
Informational
12/13/2023
Erosion control is in place at the time of under slab plumbing inspection
Miscellaneous Correction
Informational
12/13/2023
Erosion control is in place at the time of all rough. Full erosion control must be maintained until CofO
Miscellaneous Correction
Corrective Action Required
03/06/2024
Sod is not in place at the time of occupancy inspection. Full erosion control must be maintained until full CofO
Occupancy Inspection - Codes Residential Ready for Temp CO 3/7/2024 3/7/2024 03/07/2024
Miscellaneous Correction
Resolved
03/07/2024
-Must maintain erosion control -Final grade, sod and splash blocks not complete -Missing sump pump extension Inspection for Occupancy failed, if scheduling for TCO, please specify when ordering an inspection
Miscellaneous Correction
Corrective Action Required
03/07/2024
Must maintain erosion control -Final grade, sod and splash blocks not complete -Missing sump pump extension Passed for TCO only 03/07/2024 KBEARD
Plot Plan Inspection Failed 4/9/2024 04/09/2024
Miscellaneous Correction
Informational
04/09/2024
-As graded plot plan is required prior to sodding. -Sod is not installed at this time -This is for a partial inspection only 04/09/24. KBEARD
Occupancy Inspection - Codes Residential Failed 4/11/2024 04/11/2024
Miscellaneous Correction
Resolved
04/11/2024
Must maintain erosion control -Final grade, sod and splash blocks not complete -Missing sump pump extension Passed for TCO only 03/07/2024 KBEARD
Miscellaneous Correction
Corrective Action Required
04/11/2024
Must maintain erosion control -Final grade, sod and splash blocks not complete -Missing sump pump extension -Email was sent asking for a TCO extension form to be filled out. -No response from the email request -Not ready for TCO extension and fees added 04/11/2024 KBEARD
Plot Plan Inspection Passed 5/1/2024 05/01/2024
Miscellaneous Correction
Resolved
05/01/2024
-As graded plot plan is required prior to sodding. -Sod is not installed at this time -This is for a partial inspection only 04/09/24. KBEARD
Erosion Control Inspection Residential Passed 6/27/2024 06/27/2024
Miscellaneous Correction
Resolved
06/27/2024
Erosion control is in place at the time of under slab plumbing inspection
Miscellaneous Correction
Resolved
06/27/2024
Erosion control is in place at the time of all rough. Full erosion control must be maintained until CofO
Miscellaneous Correction
Resolved
06/27/2024
Sod is not in place at the time of occupancy inspection. Full erosion control must be maintained until full CofO
Occupancy Inspection - Codes Residential Full C of O 6/27/2024 6/27/2024 06/27/2024
Miscellaneous Correction
Resolved
06/27/2024
Must maintain erosion control -Final grade, sod and splash blocks not complete -Missing sump pump extension -Email was sent asking for a TCO extension form to be filled out. -No response from the email request -Not ready for TCO extension and fees added 04/11/2024 KBEARD
Documents & Images
Date Uploaded File Type Document Name
05/23/2023 OS 68 Basswood Farmhouse 2 SIGNED
05/23/2023 68 osage roof layout
05/23/2023 LOT 68 FINAL
05/23/2023 OS #68 Permit App
05/23/2023 P230231 - Osage Lot 68 - Sealed Truss Drawings
05/25/2023 Approved Plans APPROVED PLANS
05/25/2023 Approved Plans APPROVED TRUSS LAYOUT
05/25/2023 Approved Plans APPROVED TRUSS PACKAGE
05/25/2023 Permit Codes Residential Plan Review
05/25/2023 Permit Codes Residential Plan Review
05/31/2023 LOT 68 CITY
06/06/2023 Plot Plan approved plot plan
06/06/2023 Permit Codes Residential Plan Review
06/06/2023 Permit Codes Residential Plan Review
06/06/2023 Permit DS Building Permit
06/06/2023 Permit DS Building Permit
06/06/2023 Receipt Receipt for transaction:2023-003981
06/30/2023 2133 SW Rutherford Dr LSMO Osage Lot 68 Clayton Properties P 2023-2322 3rd Party Footing Inspection Report 6-29-23
06/30/2023 Letter INSPECTION SUMMARY
06/30/2023 Letter INSPECTION SUMMARY
06/30/2023 Letter INSPECTION SUMMARY
07/13/2023 Letter INSPECTION SUMMARY
07/13/2023 Letter INSPECTION SUMMARY
07/13/2023 Letter INSPECTION SUMMARY
07/13/2023 Letter INSPECTION SUMMARY
07/13/2023 Letter INSPECTION SUMMARY
07/13/2023 Letter INSPECTION SUMMARY
07/13/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter INSPECTION SUMMARY
08/29/2023 Letter INSPECTION SUMMARY
08/29/2023 Letter INSPECTION SUMMARY
08/29/2023 Letter INSPECTION SUMMARY
11/30/2023 Letter INSPECTION SUMMARY
11/30/2023 Letter INSPECTION SUMMARY
11/30/2023 Letter INSPECTION SUMMARY
12/13/2023 Letter INSPECTION SUMMARY
12/13/2023 Letter INSPECTION SUMMARY
12/13/2023 Letter INSPECTION SUMMARY
12/13/2023 Letter INSPECTION SUMMARY
12/13/2023 Letter INSPECTION SUMMARY
12/13/2023 Letter INSPECTION SUMMARY
12/13/2023 Letter INSPECTION SUMMARY
12/13/2023 Letter INSPECTION SUMMARY
12/13/2023 Letter INSPECTION SUMMARY
12/15/2023 Letter INSPECTION SUMMARY
12/15/2023 Letter INSPECTION SUMMARY
12/15/2023 Letter INSPECTION SUMMARY
12/20/2023 Letter INSPECTION SUMMARY
12/20/2023 Letter INSPECTION SUMMARY
12/21/2023 68 Osage - Truss Issue
12/21/2023 Letter INSPECTION SUMMARY
12/21/2023 Letter INSPECTION SUMMARY
12/21/2023 Letter INSPECTION SUMMARY
12/21/2023 Letter INSPECTION SUMMARY
12/21/2023 Letter INSPECTION SUMMARY
02/01/2024 Letter INSPECTION SUMMARY
02/01/2024 Letter INSPECTION SUMMARY
02/01/2024 Letter INSPECTION SUMMARY
02/05/2024 Letter INSPECTION SUMMARY
02/23/2024 Letter INSPECTION SUMMARY
02/23/2024 Letter INSPECTION SUMMARY
02/28/2024 Letter INSPECTION SUMMARY
02/28/2024 Letter INSPECTION SUMMARY
02/29/2024 Receipt Receipt for transaction:2024-001218
02/29/2024 Letter INSPECTION SUMMARY
02/29/2024 Letter INSPECTION SUMMARY
02/29/2024 Letter INSPECTION SUMMARY
02/29/2024 Letter INSPECTION SUMMARY
02/29/2024 Letter INSPECTION SUMMARY
02/29/2024 Letter INSPECTION SUMMARY
02/29/2024 Letter INSPECTION SUMMARY
02/29/2024 Letter INSPECTION SUMMARY
02/29/2024 Letter INSPECTION SUMMARY
02/29/2024 Letter INSPECTION SUMMARY
02/29/2024 Letter INSPECTION SUMMARY
02/29/2024 Letter INSPECTION SUMMARY
02/29/2024 Letter INSPECTION SUMMARY
02/29/2024 Letter INSPECTION SUMMARY
02/29/2024 Letter INSPECTION SUMMARY
02/29/2024 Letter INSPECTION SUMMARY
03/04/2024 Letter INSPECTION SUMMARY
03/04/2024 Letter INSPECTION SUMMARY
03/06/2024 Letter INSPECTION SUMMARY
03/06/2024 Letter INSPECTION SUMMARY
03/06/2024 Letter INSPECTION SUMMARY
03/06/2024 Letter INSPECTION SUMMARY
03/07/2024 Certificate/License Codes Temporary Certificate of Occupancy
03/07/2024 Certificate/License Codes Temporary Certificate of Occupancy
03/07/2024 Receipt Receipt for transaction:2024-001403
04/09/2024 Letter INSPECTION SUMMARY
04/09/2024 Letter INSPECTION SUMMARY
04/11/2024 Letter INSPECTION SUMMARY
04/11/2024 Letter INSPECTION SUMMARY
04/30/2024 LOT 68 ASBUILT
04/30/2024 Plot Plan approved as graded plot plan
05/01/2024 Letter INSPECTION SUMMARY
06/27/2024 Letter INSPECTION SUMMARY
06/27/2024 Letter Codes Final Certificate of Occupancy
06/27/2024 Letter Codes Final Certificate of Occupancy
06/27/2024 Letter Field Certificate of Occupancy
06/27/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home