Permit Application Status

PRRES20225569


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20225569
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO
11/04/2022
11/09/2022
08/31/2023
Locations
Contacts
CAPITAL CONSTRUCTION SERVICES LLC, Address:2642 NE HAGAN RD, Phone:(816) 875-0018  
Doug Rothfuss, Address:2642 HAGAN RD  
5 STAR HEATING & COOLING, Address:211 NW 12TH, Phone:(816) 517-3341  
INHOME SYSTEMS LLC, Address:510 MISSION RD SW, Phone:(816) 372-0483  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
DROTHFUSS@CAPITALCONST.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $2,064.36 $2,064.36 Paid 11/09/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 11/09/2022
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 11/09/2022
8331401-Water Tap Fee $3,730.00 $3,730.00 Paid 11/09/2022
8350015-Water Meter Fee $550.50 $550.50 Paid 11/09/2022
8331507-Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 11/09/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 08/30/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Passed 12/2/2022 12/2/2022 12/02/2022
Footing Inspection - Residential Passed 12/02/2022
Informational
12/02/2022
FOOTING APPROVED BY ENGINEER
Sewer Service Inspection - R Passed 12/2/2022 (1:00) 12/2/2022 12/02/2022
Water Service Inspection - R Failed 12/6/2022 (8:00) 12/6/2022 12/06/2022
Misc
Corrective Action Required
12/06/2022
WATER LINE WAS NOT INSPECTED AND WAS NOT INSTALLED AT SEWER INSPECTION. WATER FINAL WAS CALLED BUT THE TRENCH WAS ALREADY BACKFILLED
Piers/Caissons Inspection - Residential Failed 1/20/2023 (8:00) 1/20/2023 01/20/2023
Misc
Corrective Action Required
01/20/2023
NOT READY
Piers/Caissons Inspection - Residential Passed 2/7/2023 2/7/2023 02/07/2023
Misc
Resolved
02/07/2023
NOT READY
Electrical Service Inspection Failed 3/6/2023 3/6/2023 03/06/2023
Misc
Corrective Action Required
03/06/2023
-Bond service panel enclosure
Gas Service Inspection - Residential Passed 3/6/2023 3/6/2023 03/06/2023
All Rough Inspection - Residential Failed 3/6/2023 3/6/2023 03/06/2023
Misc
Corrective Action Required
03/06/2023
-Tighten all anchor nuts -Secure SE cable within 12” of meter entry -Fb all wall plate and floor penetrations -Triple stud support for lvl beam at laundry/garage wall -Reroute refrigerator water line and protect if required -Protect wiring at pantry bottom wall plate -Provide security blockings at exterior door to patio -Support top of hip above rear dining -Nail together kitchen I beam support studs -Protect wiring at great room bottom wall plate at rear wall and wall across stair; at upper fl bathroom -Provide wall receptacle spacing per code at rear great room -Provide min clearance from top of fireplace -Fb fireplace space from roof space; Fb master bathroom triangular wall space from roof -Install hangers at connections to master bedroom ceiling beam -Nail corner studs per code -Support hips above foyer -Install hangers at basement stair wall -Double I joist under fireplace per I joist plan **OK TO INSULATE
Electrical Service Inspection Failed 3/16/2023 3/16/2023 03/16/2023
Misc
Corrective Action Required
03/06/2023
-Bond service panel enclosure **not ready
All Rough Inspection - Residential Failed 3/16/2023 3/16/2023 03/16/2023
Misc
Corrective Action Required
03/06/2023
-Anchor sill plates within 12” of added garage door -Reroute refrigerator water line and protect if required **Protect water line -Provide security blockings at exterior door to patio -Protect wiring at wall across stair -Provide min clearance from top of fireplace **Remove wood below the triangular spacers -Install hangers at basement stair wall **Nail the hanger at lvl connection
All Rough Inspection - Residential Passed 3/21/2023 3/21/2023 03/21/2023
Misc
Resolved
03/21/2023
Electrical Service Inspection Passed 3/21/2023 3/21/2023 03/21/2023
Misc
Resolved
03/21/2023
-Bond service panel enclosure **not ready
Driveway Inspection Passed 4/3/2023 4/3/2023 04/03/2023
Misc
Informational
04/03/2023
Site visited and it appears driveway meet city standards. No sidewalk and Passed.
Occupancy Inspection - Codes Residential Failed 8/25/2023 8/25/2023 08/25/2023
Misc
Corrective Action Required
08/25/2023
-Obtain lawn irrigation permit and submit backflow valve test report to city -Water service was not inspected & approved -Complete rear patio stair -Gutter, downspouts , and sump pump extension -Correct kitchen countertop receptacles wiring-hot and ground reversed -Provide box extension for TV outlet above fireplace -Provide a readily accessible gfci for the hydrotub receptacle -Fb hole in floor inside hydrotub -Install shutoff device at auxiliary drain pan of 2nd fl furnace -Label or identify all dedicated non-gfci receptacles in garage and basement -Screw the exterior door embedded jamb braces into studs
Occupancy Inspection - Codes Residential Ready for Temp CO 8/30/2023 8/30/2023 08/30/2023
Misc
Corrective Action Required
08/25/2023
-Obtain lawn irrigation permit and submit backflow valve test report to city -Water service was not inspected & approved
Occupancy Inspection - Codes Residential Full C of O 8/31/2023 8/31/2023 08/31/2023
Misc
Resolved
08/31/2023
-Obtain lawn irrigation permit and submit backflow valve test report to city -Water service was not inspected & approved
Documents & Images
Date Uploaded File Type Document Name
11/04/2022 LS Application
11/04/2022 PLOT- lot 311 FINAL
11/07/2022 Approved Plans Approved Drawings
11/08/2022 Plot Plan Approved Plot Plan
11/08/2022 Permit Codes Residential Plan Review
11/09/2022 Permit DS Building Permit
11/09/2022 Receipt Receipt for transaction:2022-008818
11/20/2022 2012 NE Blue Stone Dr LSMO Park Ridge Lot 311 Foundation Footing Inspection Report 11-16-22
12/02/2022 Letter INSPECTION SUMMARY
12/02/2022 Letter INSPECTION SUMMARY
12/02/2022 Letter INSPECTION SUMMARY
12/06/2022 Letter INSPECTION SUMMARY
01/20/2023 Letter INSPECTION SUMMARY
02/07/2023 Letter INSPECTION SUMMARY
03/06/2023 Letter INSPECTION SUMMARY
03/06/2023 Letter INSPECTION SUMMARY
03/06/2023 Letter INSPECTION SUMMARY
03/07/2023 Plans 2012 NE Blue Stone Dr 1st Floor I-Joist Layout
03/16/2023 Letter INSPECTION SUMMARY
03/16/2023 Letter INSPECTION SUMMARY
03/21/2023 Letter INSPECTION SUMMARY
03/21/2023 Letter INSPECTION SUMMARY
04/03/2023 Letter INSPECTION SUMMARY
08/25/2023 Letter INSPECTION SUMMARY
08/30/2023 Certificate/License Codes Temporary Certificate of Occupancy
08/30/2023 Receipt Receipt for transaction:2023-006719
08/31/2023 Letter Field Certificate of Occupancy
08/31/2023 Letter Codes Final Certificate of Occupancy
08/31/2023 Letter Capital 311 Parkridge Letter
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home