Summary
PRRES20224991
Building Permit - Residential
Certificate of Occupancy
SAB CONSTRUCTION LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO
10/05/2022
10/10/2022
04/04/2023
09/18/2023
Locations
Contacts
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
SAB CONSTRUCTION LLC, Address:200 NW COMMERCE CT  
Joseph Matthew Schartz, Address:PO Box 942, Phone:(816) 524-3855  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
TEAGUE ELECTRIC CONSTRUCTION INC, Address:12425 W 92ND ST, Phone:(913) 529-4600  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
Talby Twiford, Address:PO Box 942  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,918.50 $1,918.50 Paid 10/10/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/10/2022
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 10/10/2022
8331401-Water Tap Fee $3,730.00 $3,730.00 Paid 10/10/2022
8350015-Water Meter Fee $550.50 $550.50 Paid 10/10/2022
8331507-Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 10/10/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 05/31/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 11/14/2022 11/14/2022
Misc
Corrective Action Required
11/14/2022
maintain erosion crontrol no gravel filter
Erosion Control Inspection Residential Failed 11/14/2022 11/14/2022
DCM5 ESC INSP DENIED
Corrective Action Required
11/14/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. no gravel filter
Underslab Plumbing Inspection - Residential Failed 11/14/2022 11/14/2022 11/14/2022
Misc
Corrective Action Required
11/14/2022
inspection denied maintain erosion control no gravel filter
Underslab Plumbing Inspection - Residential Passed 11/16/2022 11/16/2022 11/16/2022
Misc
Resolved
11/16/2022
inspection denied maintain erosion control no gravel filter
Footing Inspection - Residential Passed 11/18/2022 11/18/2022
Misc
Resolved
11/18/2022
maintain erosion crontrol no gravel filter
Sewer Service Inspection - R Passed 11/18/2022 (4:00) 11/18/2022 11/18/2022
Water Service Inspection - R Passed 11/22/2022 (4:00) 11/22/2022 11/22/2022
Piers/Caissons Inspection - Residential Partial 12/14/2022 (9:15) 12/14/2022 12/14/2022
Misc
Corrective Action Required
12/14/2022
East pier okay West pier not to depth
Piers/Caissons Inspection - Residential Passed 12/14/2022 (10:15) 12/14/2022 12/14/2022
Misc
Resolved
12/14/2022
East pier okay West pier not to depth
Gas Service Inspection - Residential Passed 5/3/2023 5/3/2023 05/03/2023
Electrical Service Inspection Passed 5/3/2023 5/3/2023 05/03/2023
All Rough Inspection - Residential Not Ready 5/3/2023 5/3/2023 05/03/2023
Misc
Corrective Action Required
05/03/2023
-provide complete City approved STAMPED plans on site for inspection list subject to change -Fireblock South garage wall into furr down -strike plate for penetration at top plate SE garage -fireblock s garage furred out wall to ceiling space -fireblock hvac chase to ceiling space -missing 3 stud pack at coat closet (address broken stud at this area as well) -address holes drilled closer than 2” to each other above powder room -bath vents to be 4” in diameter -fireblock dead space to ceiling space left of fireplace -fireblock fireplace to ceiling space -address any and all holes drilled in floor joist above great room, breakfast & kitchen closer than 2” to one another or the edge of the joist -Address floor joist above pantry landing on N pantry non load bearing wall -tighten nuts for through bolts above bed 4 -missing stud pack at bed 3/4 bath east and west wall -missing lib at bed 3/4 bath S wall -lib not to plans at bed 2 bath N wall -missing stud at bed 2 bath N wall -fireblock master bath entry wall, west wall, closet and entry wall to ceiling space -missing nails in hangers above master closet -protect NM within 6’ of attic access -fireblock left of laundry hvac chase to ceiling space -address holes drilled closer than 2” to each other in floor joist W basement -
All Rough Inspection - Residential Failed 6/1/2023 6/1/2023 06/01/2023
Misc
Corrective Action Required
05/03/2023
-fireblock s garage furred out wall to ceiling space -fireblock hvac chase to ceiling space -missing 3 stud pack at coat closet (address broken stud at this area as well) -fireblock fireplace to ceiling space -missing 3 stud pack at bed 3/4 bath E wall -fireblock master closet entry wall to ceiling space
All Rough Inspection - Residential Passed 6/2/2023 6/2/2023 06/02/2023
Misc
Resolved
06/02/2023
-fireblock s garage furred out wall to ceiling space -fireblock hvac chase to ceiling space -missing 3 stud pack at coat closet (address broken stud at this area as well) -fireblock fireplace to ceiling space -missing 3 stud pack at bed 3/4 bath E wall -fireblock master closet entry wall to ceiling space
Driveway Inspection Failed 8/18/2023 07/20/2023
DCM5 ESC INSP DENIED
Resolved
07/20/2023
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. no gravel filter
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/20/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Maintain silt fence and overgrown vegetation
Driveway Inspection Partial 8/18/2023 8/18/2023 08/18/2023
Misc
Informational
08/18/2023
8-18-23 A.A DW is formed, aggregate is compacted. Will need to maintain 2% slope through driveway but conditions can change, approved to pour
Driveway Inspection Passed 9/1/2023 9/1/2023 09/01/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/18/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Maintain silt fence and overgrown vegetation 9-1-23 A.A DW is poured to city standards . Forms are pulled. Passed
Plot Plan Inspection Passed 9/15/2023 09/15/2023
Erosion Control Inspection Residential Passed 9/18/2023 09/18/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
09/18/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Maintain silt fence and overgrown vegetation
Occupancy Inspection - Codes Residential Full C of O 9/18/2023 9/18/2023 09/18/2023
Documents & Images
Date Uploaded File Type Document Name
10/05/2022 HFR096 - Permit Application
10/05/2022 HFR096 - Excise Tax Application
10/05/2022 HFR096 - Air Combustion Calculations
10/06/2022 Permit Codes Residential Plan Review
10/10/2022 Plot Plan Approved Plot Plan
10/10/2022 Approved Plans Approved Drawings
10/10/2022 Permit Codes Residential Plan Review
10/10/2022 Permit DS Building Permit
10/10/2022 Receipt Receipt for transaction:2022-008144
10/17/2022 M L Crose 2037 SW arvest Moon Ln LSMO Footin Inspection Report 10-17-22
11/14/2022 Letter INSPECTION SUMMARY
11/14/2022 Letter INSPECTION SUMMARY
11/14/2022 Letter INSPECTION SUMMARY
11/18/2022 Letter INSPECTION SUMMARY
11/18/2022 Letter INSPECTION SUMMARY
11/18/2022 Letter INSPECTION SUMMARY
11/22/2022 Letter INSPECTION SUMMARY
12/14/2022 Letter INSPECTION SUMMARY
05/03/2023 Letter INSPECTION SUMMARY
05/03/2023 Letter Codes 140 Day Letter
05/03/2023 Letter INSPECTION SUMMARY
05/03/2023 Letter INSPECTION SUMMARY
05/03/2023 Letter INSPECTION SUMMARY
05/24/2023 DW FRAMING INSPECTION RESPONSE HFR096 Redbud ll 2037 SW Harvest Moon Lane 5-4-23
05/31/2023 Receipt Receipt for transaction:2023-003794
06/01/2023 Letter INSPECTION SUMMARY
06/02/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter INSPECTION SUMMARY
08/18/2023 Letter INSPECTION SUMMARY
09/01/2023 Letter INSPECTION SUMMARY
09/14/2023 Plot Plan APPROVED AS BUILT PLOT PLAN
09/15/2023 Letter INSPECTION SUMMARY
09/18/2023 Letter Codes Final Certificate of Occupancy
09/18/2023 Letter Field Certificate of Occupancy
09/18/2023 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home