Permit Application Status

PRRES20222990


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20222990
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. COVERED PATIO. UNFINISHED BASEMENT. STOP WORK ORDER generated on 05/04/2023 12:00 AM by username 'Robb Popp'. STOP WORK ORDER removed on 05/18/2023 12:00 AM by username 'Robb Popp'.
06/29/2022
08/11/2022
01/09/2023
08/15/2023
Locations
Contacts
KC CUSTOM HOMES, Address:406 NW DONOVAN RD, Phone:(816) 564-5149  
Steve Froehlich, Address:406 NW Donovan Rd  
ONE HOUR HEATING & AIR CONDITIONING, Address:712 SW BLUE PKWY, Unit A, Phone:(816) 524-2121  
THE SOLAR GUYS, Address:6114 MO-9 HWY STE C1, Phone:(913) 424-2112  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
STEVE@KC-CUSTOMHOMES.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $630.00 $630.00 Paid 08/11/2022
Water Tap Fee $3,655.00 $3,655.00 Paid 08/11/2022
Water Meter Fee $479.24 $479.24 Paid 08/11/2022
Right of Way Permit Fee $85.00 $85.00 Paid 08/11/2022
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 08/11/2022
Valuation Fee New Single Family $1,688.31 $1,688.31 Paid 08/11/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 9/6/2022 09/06/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/06/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - SPREAD GRAVEL FILTER AT DRIVEWAY -
Footing Inspection - Residential Passed 9/6/2022 (11:00) 9/6/2022 09/06/2022
Misc
Informational
09/06/2022
UFER LOCATED NORTH WALL AT STEP DOWN BEHIND GARAGE
Erosion Control Inspection Residential Failed 9/30/2022 09/30/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/06/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - SPREAD GRAVEL FILTER AT DRIVEWAY -
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/30/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - SPREAD GRAVEL FILTER AT DRIVEWAY - - MAINTAIN GUTTER BUDDY & REMOVE SILT DEPOSITS AT CURB INLET -
Underslab Plumbing Inspection - Residential Failed 9/30/2022 9/30/2022 09/30/2022
Miscellaneous Correction
Corrective Action Required
09/30/2022
COMPLETE DWV ( NOT READY ) Michael Harkins 09/30/2022 8:47 AM
Underslab Plumbing Inspection - Residential Passed 10/5/2022 10/05/2022
Miscellaneous Correction
Resolved
10/05/2022
Suspended Slab Inspection Passed 10/19/2022 (11:00) 10/19/2022 10/19/2022
Misc
Informational
10/19/2022
FRONT STOOP
Piers/Caissons Inspection - Residential Passed 10/28/2022 10/28/2022
Misc
Informational
10/28/2022
3RD PARTY DECK PIERS (3) 24" X 36" BY STEVEN FITCH @ APEX SIGNED & SEALED BY CLAYTON HESS UPLOADED TO PERMIT
Sewer Service Inspection - R Passed 12/19/2022 (11:15) 12/19/2022 12/19/2022
Water Service Inspection - R Passed 12/20/2022 (1:00) 12/20/2022 12/20/2022
Electrical Service Inspection Passed 2/16/2023 2/16/2023 02/16/2023
Gas Service Inspection - Residential Failed 2/16/2023 2/16/2023 02/16/2023
Misc
Corrective Action Required
02/16/2023
-Complete gas piping to fireplace and perform pressure test
Erosion Control Inspection Residential Failed 02/16/2023
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/30/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - SPREAD GRAVEL FILTER AT DRIVEWAY -
DCM2 ESC DEFICIENT INSTALLATION
Resolved
02/16/2023
DEFICIENT EROSION CONTROL INSTALLATION. - MAINTAIN GRAVEL FILTER AT DRIVEWAY - 6" MIN LIFT OF 3/4" GRAVEL REQUIRED - MAINTAIN GUTTER BUDDY & REMOVE SILT DEPOSITS AT CURB INLET - -CLEAN DEBRIS FROM STREET
Erosion Control Inspection Residential Failed 02/16/2023
DCM2 ESC DEFICIENT INSTALLATION
Resolved
02/16/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - SPREAD GRAVEL FILTER AT DRIVEWAY -
Miscellaneous Correction
Corrective Action Required
02/16/2023
DEFICIENT EROSION CONTROL INSTALLATION. - MAINTAIN GRAVEL FILTER AT DRIVEWAY - 6" MIN LIFT OF 3/4" GRAVEL REQUIRED - MAINTAIN GUTTER BUDDY & REMOVE SILT DEPOSITS AT CURB INLET - -CLEAN DEBRIS FROM STREET
All Rough Inspection - Residential Failed 2/16/2023 2/16/2023 02/16/2023
Misc
Corrective Action Required
02/16/2023
-Repaint address before further inspection -Provide gravel filter at drive-(6" lift of 3/4" gravel) **Exterior not inspected due to conditions -Install anchor bolt at end plate at PFH exterior corner -Nail exterior corners and intersecting wall studs per code -Missing hanger nails at tail joist near single car bay and at double hanger near beam -Anchor bolts to be in middle third of plate -Address/clarify missing HSS columns at garage -Secure water service lines -Missing column in basement SW storage area -Overnotched joist near beam for master bath dwv -Furdown hvac for R19 insulation -Fireblock hvac chases -Complete fireblocking at ceiling line in garage -Support hip joist above single car bay -Protect DWV 2” above plate line in garage -Address holes bored over 40% at load bearing wall in laundry-See near cut out top plate missing fireblocking -Fireblock dead space in laundry -Missing hanger nails in laundry at header joist -Missing nails at double hanger above refrigerator -Address/clarify (3) 2x4s used instead column shown on plans resting directly on beam below by stairs -Complete gas piping to fireplace-also csst is not allowed through the fireplace enclosure -Uncover covered patio roof framing for inspection -Install all missing windows -Install floor receptacle at stairwell -Correct over bored stud at load bearing wall in master bath/ hallway -Have engineer address broken hip joist in master bath near exterior corner -Support hip joists in attic space to bearing walls below -Seal through floor penetration at bath 2 -Use Simpson HHUS hanger at LVL beams upstairs per plan -Missing all LIB bracing on second floor-see sheet 6 -Provide lateral restraint at LVL beam above stair landing -Seal plate penetration at upstairs hall closet -Provide joist hanger at tail joist for attic access upstairs bath -Fireblock dead space at exterior corner bath 4 -Seal through floor penetration bath 4 -Missing column in basement SW storage area -Over notched joist near beam for master dwv above
Erosion Control Inspection Residential Partial 3/17/2023 03/17/2023
Miscellaneous Correction
Informational
03/17/2023
- EROSION CONTROL SATISFACTORY AT TIME OF INSPECTION.
Gas Service Inspection - Residential Passed 3/17/2023 03/17/2023
Misc
Resolved
03/17/2023
All Rough Inspection - Residential Failed 3/17/2023 3/17/2023 03/17/2023
Misc
Corrective Action Required
02/16/2023
-Address holes bored over 40% at load bearing wall in laundry-See near cut out top plate missing fireblocking (stud shoes near top plate ) -Complete fireplace-also fb penetrations to basement
All Rough Inspection - Residential Passed 3/22/2023 3/22/2023 03/22/2023
Misc
Resolved
03/22/2023
Driveway Inspection Partial 3/30/2023 3/30/2023 03/30/2023
Misc
Informational
03/30/2023
3-30-23 DP. DW is formed, aggregate is compacted. Approved to pour
Erosion Control Inspection Residential Failed 05/01/2023
Miscellaneous Correction
Resolved
05/01/2023
- EROSION CONTROL SATISFACTORY AT TIME OF INSPECTION.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/01/2023
5/1/23 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Failed - Stop Work 5/4/2023 5/4/2023 05/04/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/01/2023
5/1/23 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
05/04/2023
5/4/23 EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. STOP WORK ORDER ISSUED
Erosion Control Inspection Residential Failed - Stop Work 05/17/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/04/2023
5/1/23 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
05/04/2023
5/4/23 EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. STOP WORK ORDER ISSUED
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
05/17/2023
5/17/23 STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. STOP WORK ORDER POSTED
Erosion Control Inspection Residential Partial 5/18/2023 5/18/2023 05/18/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
05/18/2023
5/1/23 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
05/18/2023
5/4/23 EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. STOP WORK ORDER ISSUED
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
05/18/2023
5/17/23 STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. STOP WORK ORDER POSTED
Misc
Corrective Action Required
05/18/2023
5/18/23 EROSION CONTROL IN COMPLIANCE AT TIME OF INSPECTION
Erosion Control Inspection Residential Failed 06/21/2023
Misc
Corrective Action Required
05/18/2023
6/21/23 -Restore silt fence at perimeter
Erosion Control Inspection Residential Failed 08/08/2023
Misc
Resolved
08/08/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/08/2023
8/8/23 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Passed 8/11/2023 8/11/2023 08/11/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
08/11/2023
Sod in place
Occupancy Inspection - Codes Residential Failed 8/14/2023 8/14/2023 08/14/2023
Misc
Corrective Action Required
08/14/2023
-Driveway insepction pending -Complete gutters, downspouts and extensions -Label all non GFCI protected outlets -Install secondary lock at sliding glass door -Install security screws per code -Provide ladders at egress wells -Secure pex at backflow device in basement -Gaurdrail at second level to be min 36"
Driveway Inspection Passed 8/15/2023 8/15/2023 08/15/2023
Misc
Informational
03/30/2023
3-30-23 DP. DW is formed, aggregate is compacted. Approved to pour 8-15-23 DP. DW was poured, forms removed. Passed.
Plot Plan Inspection Passed 8/15/2023 08/15/2023
Occupancy Inspection - Codes Residential Full C of O 8/15/2023 8/15/2023 08/15/2023
Misc
Resolved
08/15/2023
-Provide ladders at egress wi
Documents & Images
Date Uploaded File Type Document Name
06/30/2022 Permit Application
06/30/2022 Excise Tax Application
07/13/2022 Permit Codes Residential Plan Review
07/18/2022 Plot Plan APPROVED PLOT PLAN
07/18/2022 Approved Plans APPROVED PLANS
07/18/2022 Permit Codes Residential Plan Review
08/11/2022 Permit DS Building Permit
08/11/2022 Receipt Receipt for transaction:2022-006609
09/06/2022 Letter INSPECTION SUMMARY
09/06/2022 Letter INSPECTION SUMMARY
09/06/2022 Letter INSPECTION SUMMARY
09/30/2022 Letter INSPECTION SUMMARY
09/30/2022 Letter INSPECTION SUMMARY
10/05/2022 Letter INSPECTION SUMMARY
10/19/2022 Letter INSPECTION SUMMARY
10/28/2022 Engineer Report/Study Final_2022_10_07_DPier_LSMO_Pat Cochran Concrete
10/28/2022 Letter INSPECTION SUMMARY
12/19/2022 Letter INSPECTION SUMMARY
12/20/2022 Letter INSPECTION SUMMARY
02/16/2023 Letter INSPECTION SUMMARY
02/16/2023 Letter INSPECTION SUMMARY
02/16/2023 Letter INSPECTION SUMMARY
02/16/2023 Letter INSPECTION SUMMARY
02/16/2023 Letter INSPECTION SUMMARY
03/15/2023 Engineering Report Framing Issues
03/17/2023 Letter INSPECTION SUMMARY
03/17/2023 Letter INSPECTION SUMMARY
03/17/2023 Letter INSPECTION SUMMARY
03/22/2023 Letter INSPECTION SUMMARY
03/30/2023 Letter INSPECTION SUMMARY
05/01/2023 Letter INSPECTION SUMMARY
05/04/2023 Letter Stop Work Order
05/04/2023 Letter INSPECTION SUMMARY
05/17/2023 Letter Stop Work Order
05/18/2023 Letter INSPECTION SUMMARY
06/21/2023 Letter INSPECTION SUMMARY
08/08/2023 Letter INSPECTION SUMMARY
08/11/2023 Letter INSPECTION SUMMARY
08/14/2023 Letter INSPECTION SUMMARY
08/15/2023 Letter INSPECTION SUMMARY
08/15/2023 Letter INSPECTION SUMMARY
08/15/2023 Letter Field Certificate of Occupancy
08/15/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home