Summary
PRRES20222969
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UFINSIHED BASEMENT - COVERED DECK
06/28/2022
07/08/2022
10/04/2023
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
Ashley Kirby, Address:5207 NW Crooked Rd, Phone:(816) 969-9010  
ASHLEY@NEWMARKHOMESKC.COM  
HARRINGTON BROTHERS HEATING & COOLING, Address:15630 S KEELER ST, Phone:(913) 422-5444  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
ELECTRICAL INVESTMENTS, Address:8014 REEDER ST, Phone:(816) 210-1597  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $630.00 $630.00 Paid 07/08/2022
Right of Way Permit Fee $85.00 $85.00 Paid 07/08/2022
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 07/08/2022
Water Tap Fee $3,730.00 $3,730.00 Paid 07/08/2022
Water Meter Fee $550.50 $550.50 Paid 07/08/2022
Valuation Fee New Single Family $1,912.65 $1,912.65 Paid 07/08/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/12/2022 (1:00) 9/12/2022 09/12/2022
Misc
Informational
09/12/2022
UFER LOCATED NW CORNER BASEMENT
Underslab Plumbing Inspection - Residential Passed 10/4/2022 10/4/2022 10/04/2022
Piers/Caissons Inspection - Residential Passed 10/19/2022 10/19/2022
Misc
Informational
10/19/2022
3RD PARTY BY TODD LANGENHORST @ VAN DEURZEN 24" DECK PIERS APPROVED UPLOADED TO PERMIT
Sewer Service Inspection - R Passed 12/19/2022 (8:15) 12/19/2022 12/19/2022
Water Service Inspection - R Passed 12/19/2022 (10:00) 12/19/2022 12/19/2022
Electrical Service Inspection Passed 3/28/2023 3/28/2023 03/28/2023
Gas Service Inspection - Residential Passed 3/28/2023 3/28/2023 03/28/2023
All Rough Inspection - Residential Failed 3/28/2023 3/28/2023 03/28/2023
Misc
Corrective Action Required
03/28/2023
2067 -missing nail at hanger above entry -address holes drilled too close together and with two inches of edge of joist -missing nails at LIB top right entry -missing sill plate bolts in garage  -missing nail at top plate to header at PFH -fire block HVAC chase in the garage fur down  -fire block east wall in garage  -protect nm within 6 ft of attic access -seal joist space above owner's closet used for return air -missing nails in hangers 1st floor hallway  -fire block HVAC chase to ceiling owners closet  -address holes bored in DWV in master bath for load bearing wall (see figure R 602.6. (1) -fire block in kitchen under upstairs tub -missing nails at LIB in kitchen  -fire block right side ceiling of fireplace  -fire block furred out wall left of fireplace -provide stud pack at triple LVL at stair well wall -properly attach steel columns at 1st floor to beam -fire block south wall loft to ceiling space -address south loft wall resting on blocks above beam -fire blocking at south wall bedroom 5 at split 2x4 -address rafters landing on multiple top plates bedroom 4 east wall -fire block bed 4 closet multiple areas to ceiling space  -nails missing LIB upstairs hallway  -missing nails at hanger bed 3 closet -bed 3 LIB improper angle -stud pack at bottom of stairs basement  -address cut floor joist under master bathroom  -tighten all anchor bolts basement  -address exterior stud notched for anchor bolts basement  -anchor bolts need to be in the middle third basement  -uncover covered deck and entry ceiling -uncover PFH exterior -address deck post to beam connection -maintain erosion control -address great room CSPF nailing not to code -
All Rough Inspection - Residential Failed 4/14/2023 4/14/2023 04/14/2023
Misc
Corrective Action Required
03/28/2023
-address holes drilled too close together and with two inches of edge of joist( partially fixed. New holes drilled do not meet code and some holes not addressed) -protect nm within 6 ft of attic access -missing nails in hanger and hanger 1st floor hall -provide stud pack at triple LVL at stair well wall -uncover covered deck and entry ceiling -uncover PFH exterior -maintain erosion control -address great room CSPF nailing not to code
Erosion Control Inspection Residential Failed 04/14/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/14/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/14/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Miscellaneous Inspection Passed 4/17/2023 4/17/2023 04/17/2023
Misc
Informational
04/17/2023
Met with Craig on side to discuss outstanding all rough items.
All Rough Inspection - Residential Passed 4/20/2023 4/20/2023 04/20/2023
Misc
Resolved
04/20/2023
-address holes drilled too close together and with two inches of edge of joist( partially fixed. New holes drilled do not meet code and some holes not addressed) -protect nm within 6 ft of attic access -missing nails in hanger and hanger 1st floor hall -provide stud pack at triple LVL at stair well wall -uncover covered deck and entry ceiling -uncover PFH exterior -maintain erosion control -address great room CSPF nailing not to code
Driveway Inspection Partial 5/4/2023 5/4/2023 05/04/2023
Misc
Informational
05/04/2023
Site Visited and driveway meets city standards. Passed there is no sidewalk.
Erosion Control Inspection Residential Failed 08/08/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
08/08/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
08/08/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Misc
Corrective Action Required
08/08/2023
MAINTAIN VEGETATION
Erosion Control Inspection Residential Failed 08/21/2023
Misc
Resolved
08/21/2023
MAINTAIN VEGETATION
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/21/2023
8/21/23 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. CLEAN MUD FROM STREET, SILT FROM STORM INLET, REPAIR SILT FENCE AT SIDES, AND INSTALL EROSION CONTROL AT FRONT OF LOT IF NOT IN COMPLIANCE IN 2 BUSINESS DAY, STOP WORK WILL BE ISSUED
Erosion Control Inspection Residential Partial 8/25/2023 8/25/2023 08/25/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
08/25/2023
8/21/23 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. CLEAN MUD FROM STREET, SILT FROM STORM INLET, REPAIR SILT FENCE AT SIDES, AND INSTALL EROSION CONTROL AT FRONT OF LOT IF NOT IN COMPLIANCE IN 2 BUSINESS DAY, STOP WORK WILL BE ISSUED
Misc
Corrective Action Required
08/25/2023
Erosion control in compliance at time of inspection
Plot Plan Inspection Passed 9/1/2023 09/01/2023
Occupancy Inspection - Codes Residential Failed 9/1/2023 9/1/2023 09/01/2023
Misc
Corrective Action Required
09/01/2023
-label non gfci's in garage -missing water hammer devices in laundry -Install junction box and approved appliance connector for hood -address light fixture too close to shelf in upstairs east bedroom closet -trim drain at egress window well at the back of the house -missing splash blocks
Occupancy Inspection - Codes Residential Full C of O 10/4/2023 10/4/2023 10/04/2023
Misc
Resolved
10/04/2023
Documents & Images
Date Uploaded File Type Document Name
07/05/2022 Permit Application
07/07/2022 Approved Plans APPROVED PLANS
07/07/2022 Plot Plan approved plot plan
07/07/2022 Permit Codes Residential Plan Review
07/08/2022 Permit DS Building Permit
07/08/2022 Receipt Receipt for transaction:2022-005601
09/12/2022 Letter INSPECTION SUMMARY
10/04/2022 Letter INSPECTION SUMMARY
10/18/2022 2067 NW O'Brien Rd_DECK PIER INSP_2022-10-10
10/19/2022 Letter INSPECTION SUMMARY
12/09/2022 Final_2022_12_02_PortFme_LSMO_New Mark Homes
12/19/2022 Letter INSPECTION SUMMARY
12/19/2022 Letter INSPECTION SUMMARY
03/28/2023 Letter INSPECTION SUMMARY
03/28/2023 Letter INSPECTION SUMMARY
03/28/2023 Letter INSPECTION SUMMARY
04/07/2023 2023_04_04_2067 NW O'Brien Rd_LSMO_Discrepancy Response_Sealed
04/14/2023 Letter INSPECTION SUMMARY
04/14/2023 Letter INSPECTION SUMMARY
04/17/2023 Letter INSPECTION SUMMARY
04/20/2023 Letter INSPECTION SUMMARY
05/04/2023 Letter INSPECTION SUMMARY
08/08/2023 Letter INSPECTION SUMMARY
08/21/2023 Letter INSPECTION SUMMARY
08/25/2023 Letter INSPECTION SUMMARY
09/01/2023 Letter INSPECTION SUMMARY
09/01/2023 Letter INSPECTION SUMMARY
10/04/2023 Letter Field Certificate of Occupancy
10/04/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home