Summary
PRRES20221553
Building Permit - Residential
Issued
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK - SUSPENDED STOOP STOP WORK ORDER generated on 12/09/2024 12:00 AM by username 'Dustin Agcopra'. STOP WORK ORDER removed on 12/10/2024 12:00 AM by username 'Mitchell Schwarz'.
04/18/2022
04/26/2022
10/16/2022
Locations
Contacts
D AND D BUILDING INC, Address:PO BOX 7014, Phone:(816) 491-2125  
Kevin Stallings, Address:1100 NE Delta School Rd, Phone:(816) 491-2125  
DANDDBUILDINGCO@GMAIL.COM  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
TEAGUE ELECTRIC CONSTRUCTION INC, Address:12425 W 92ND ST, Phone:(913) 529-4600  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $510.00 $510.00 Paid 04/26/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 04/26/2022
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 04/26/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 04/26/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 04/26/2022
9110078-Valuation Fee New Single Family $1,220.34 $1,220.34 Paid 04/26/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 06/18/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 04/14/2025
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 04/14/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Pending
Occupancy Inspection - Codes Residential Pending
Misc
Corrective Action Required
03/28/2025
-pay all fees -Provide as graded plot plan
Footing Inspection - Residential Passed 7/8/2022 (8:45) 7/8/2022 07/08/2022
Underslab Plumbing Inspection - Residential Failed 9/13/2022 9/13/2022 09/13/2022
Misc
Corrective Action Required
09/13/2022
Inspection denied no address posted erosion control not in compliance
Underslab Plumbing Inspection - Residential Passed 9/21/2022 09/21/2022
Misc
Resolved
09/21/2022
Inspection denied no address posted erosion control not in compliance
Erosion Control Inspection Residential Passed 12/8/2022 12/8/2022 12/08/2022
Sewer Service Inspection - R Passed 12/30/2022 12/30/2022
Water Service Inspection - R Passed 1/3/2023 (11:15) 1/3/2023 01/03/2023
Piers/Caissons Inspection - Residential Passed 1/4/2023 (1:30) 1/4/2023 01/04/2023
Erosion Control Inspection Residential Failed 2/22/2023 02/22/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/22/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/22/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Erosion Control Inspection Residential Failed 7/20/2023 07/20/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
07/20/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
07/20/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Misc
Corrective Action Required
07/20/2023
Maintain overgrown vegetation
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/20/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Failed 9/22/2023 09/22/2023
Misc
Corrective Action Required
07/20/2023
Maintain overgrown vegetation and remove contruction debries and trash from lot. Mitchell Schwarz 09/22/2023 10:58 AM
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/20/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Failed 02/07/2024
Misc
Resolved
02/07/2024
Maintain overgrown vegetation and remove contruction debries and trash from lot. Mitchell Schwarz 09/22/2023 10:58 AM
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
09/22/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/07/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. REPAIR DOWNED AND REPLACE MISSING SILT FENCE
All Rough Inspection - Residential Not Ready 6/4/2024 6/4/2024 06/04/2024
Misc
Corrective Action Required
06/04/2024
-Properly install boca on Lara for dwv in garage entry desk area -seal top plate penetration at garage entry -3 studs required at all exterior all corners See garage/ pantry -address rear great room wall not framed to plans and address header size -install fireplace -seal hvac chase to furr down -missing double lvl in master -missing lib throughout Have design professional address details on plans assuming for lib bracing and wsp walls. Please revise and submit. -fire block dead space at bed3/4 bath -bring hvac vent to ceiling lever in basement unfinished area -provide engineered floor Joist plans on site and uploaded to permit.
All Rough Inspection - Residential Not Ready 6/21/2024 6/21/2024 06/21/2024
Misc
Corrective Action Required
06/04/2024
-Properly install boca plate for dwv in garage entry desk area -seal top plate penetration at garage entry -3 studs required at all exterior all corners See garage/ pantry -address rear great room wall not framed to plans and address header size -complete install fireplace -seal hvac chase to furr down/ceiling space in great room -missing double lvl in master -missing lib throughout Have design professional address details on plans assuming for lib bracing and wsp walls. Please revise and submit. -fire block dead space at bed3/4 bath -bring hvac vent to ceiling lever in basement unfinished area -provide engineered floor Joist plans on site and uploaded to permit.
Piers/Caissons Inspection - Residential Failed 8/14/2024 08/14/2024
Misc
Corrective Action Required
08/14/2024
Rebar in piers is not to plans
Erosion Control Inspection Residential Failed 08/14/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/07/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/07/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. REPAIR DOWNED SILT FENCE MAINTAIN OVERGROWN VEGETATION
All Rough Inspection - Residential Failed 8/15/2024 8/15/2024 08/15/2024
Misc
Corrective Action Required
06/21/2024
-address rear great room wall not framed to plans and address header size -complete install fireplace (secure gas line) -seal hvac chase to furr down/ceiling space in great room
All Rough Inspection - Residential Failed 10/2/2024 10/2/2024 10/02/2024
Misc
Corrective Action Required
08/15/2024
-address rear great room wall not framed to plans and address header size - ( Engineer correction is strap from top plate to 18” below header, not done this way) -complete install fireplace (secure gas line)
Erosion Control Inspection Residential Failed 10/2/2024 10/02/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
10/02/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM2 ESC DEFICIENT INSTALLATION
Resolved
10/02/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. REPAIR DOWNED SILT FENCE MAINTAIN OVERGROWN VEGETATION
Misc
Corrective Action Required
10/02/2024
- REMOVE TRASH AND DEBRIS FROM LOT
All Rough Inspection - Residential Passed 10/10/2024 10/10/2024 10/10/2024
Misc
Resolved
10/10/2024
-address rear great room wall not framed to plans and address header size - ( Engineer correction is strap from top plate to 18” below header, not done this way) -complete install fireplace
Driveway Inspection Partial 11/6/2024 11/6/2024 11/06/2024
Misc
Informational
11/06/2024
11-6-24 Dustin A, Dw is formed and compacted. Approach was to wide when arrived ( 40 ft ). Contractor took off wings it is now at 36 ft. Approved to pour.
Driveway Inspection Passed 11/13/2024 11/13/2024 11/13/2024
Misc
Informational
11/06/2024
11-6-24 Dustin A, Dw is formed and compacted. Approach was to wide when arrived ( 40 ft ). Contractor took off wings it is now at 36 ft. Approved to pour. 10-13-24 Dustin A, DW is poured to city specs. Passed
Erosion Control Inspection Residential Failed 12/5/2024 12/5/2024 12/05/2024
Misc
Corrective Action Required
10/02/2024
- REMOVE TRASH AND DEBRIS FROM LOT
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
12/05/2024
12-5-24 Dustin A, EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Silt fence down
Erosion Control Inspection Residential Failed - Stop Work 12/9/2024 12/9/2024 12/09/2024
Misc
Corrective Action Required
12/05/2024
- REMOVE TRASH AND DEBRIS FROM LOT
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
12/05/2024
12-5-24 Dustin A, EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Silt fence down 12-6-24 Dustin A, Silt fence still down
Erosion Control Inspection Residential Partial 12/10/2024 12/10/2024 12/10/2024
Misc
Resolved
12/10/2024
- REMOVE TRASH AND DEBRIS FROM LOT
DCM3 ESC REQUIRED 2 DAY
Resolved
12/10/2024
12-5-24 Dustin A, EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Silt fence down 12-6-24 Dustin A, Silt fence still down
Gas Service Inspection - Residential Not Ready 12/13/2024 12/13/2024 12/13/2024
Misc
Corrective Action Required
12/13/2024
No pressure at gas gauge outside. No access to inspect gas line inside.
Gas Service Inspection - Residential Passed 12/19/2024 12/19/2024 12/19/2024
Misc
Resolved
12/19/2024
No pressure at gas gauge outside. No access to inspect gas line inside.
Occupancy Inspection - Codes Residential Failed 3/24/2025 3/24/2025 03/24/2025
Misc
Corrective Action Required
03/24/2025
Inspection denied, Erosion control not in compliance.
Occupancy Inspection - Codes Residential Failed 3/24/2025 3/24/2025 03/24/2025
Misc
Corrective Action Required
03/24/2025
-Inspection denied house locked Address pending suspended slab inspection and electrical service inspection before scheduling occupancy inspection.
Electrical Service Inspection Failed 03/25/2025
Misc
Corrective Action Required
03/25/2025
Uncover and identify ufer ground connection
Occupancy Inspection - Codes Residential Failed 3/25/2025 3/25/2025 03/25/2025
Misc
Corrective Action Required
03/24/2025
-pay all fees -Provide as graded plot plan -uncover and identify ufer ground connection
Electrical Service Inspection Passed 03/28/2025
Misc
Resolved
03/28/2025
Uncover and identify ufer ground connection
Occupancy Inspection - Codes Residential Failed 3/28/2025 3/28/2025 03/28/2025
Misc
Corrective Action Required
03/25/2025
-pay all fees -Provide as graded plot plan
Plot Plan Inspection Passed 4/21/2025 04/21/2025
Documents & Images
Date Uploaded File Type Document Name
04/19/2022 45ww application
04/19/2022 Permit Codes Residential Plan Review
04/20/2022 Plot Plan APPROVED PLOT PLAN
04/21/2022 Approved Plans APPROVED PLANS
04/21/2022 Permit Codes Residential Plan Review
04/26/2022 Permit DS Building Permit
04/26/2022 Receipt Receipt for transaction:2022-002417
07/08/2022 Letter INSPECTION SUMMARY
12/08/2022 Letter INSPECTION SUMMARY
12/30/2022 Letter INSPECTION SUMMARY
01/03/2023 Letter INSPECTION SUMMARY
01/03/2023 Letter INSPECTION SUMMARY
01/03/2023 Letter INSPECTION SUMMARY
01/03/2023 Letter INSPECTION SUMMARY
01/04/2023 Letter INSPECTION SUMMARY
02/22/2023 Letter INSPECTION SUMMARY
07/12/2023 Letter Codes 140 Day Letter
07/20/2023 Letter INSPECTION SUMMARY
09/22/2023 Letter INSPECTION SUMMARY
09/25/2023 Letter Codes 180 Day Letter
11/09/2023 permit ext request
02/07/2024 Letter INSPECTION SUMMARY
06/04/2024 Letter INSPECTION SUMMARY
06/06/2024 Permit 20221553 Extension Request
06/18/2024 Receipt Receipt for transaction:2024-004857
06/21/2024 Letter INSPECTION SUMMARY
07/11/2024 Approved Plans approved joist layout
08/14/2024 Letter INSPECTION SUMMARY
08/14/2024 Letter INSPECTION SUMMARY
08/15/2024 Letter INSPECTION SUMMARY
09/23/2024 3RD Party Insp Report 1616 SW 27th St_ Lot 45 WW Comment Response
10/02/2024 Letter INSPECTION SUMMARY
10/02/2024 Letter INSPECTION SUMMARY
10/10/2024 Letter INSPECTION SUMMARY
11/06/2024 Letter INSPECTION SUMMARY
11/13/2024 Letter INSPECTION SUMMARY
12/05/2024 Letter INSPECTION SUMMARY
12/05/2024 Letter INSPECTION SUMMARY
12/09/2024 Letter Stop Work Order
12/09/2024 Letter Stop Work Order
12/10/2024 Letter INSPECTION SUMMARY
12/13/2024 Letter INSPECTION SUMMARY
12/19/2024 Letter INSPECTION SUMMARY
03/24/2025 Letter INSPECTION SUMMARY
03/24/2025 Letter INSPECTION SUMMARY
03/25/2025 Letter INSPECTION SUMMARY
03/25/2025 Letter INSPECTION SUMMARY
03/28/2025 Letter INSPECTION SUMMARY
03/28/2025 Letter INSPECTION SUMMARY
04/14/2025 Receipt Receipt for transaction:2025-002287
04/18/2025 Plot Plan APPROVED AS BUILT PLOT PLAN
04/21/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home