Permit Application Status

PRRES20220773


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20220773
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. COVERED PATIO.
03/02/2022
03/08/2022
06/13/2023
Locations
Contacts
WALKER CUSTOM HOMES, LLC, Address:PO BOX 3194, Phone:(913) 208-2026  
Jason walker, Address:PO Box 247, Phone:(913) 208-2026  
R-MECH HEATING COOLING PLUMBING/RHODES HEATING COOLING PLUMBING AND ROOTER, Address:1425 AGNES AVE, Phone:(816) 920-5955  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
JASONFW1@COMCAST.NET  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $570.00 $570.00 Paid 03/08/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 03/08/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 03/08/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 03/08/2022
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 03/08/2022
9110078-Valuation Fee New Single Family $1,403.80 $1,403.80 Paid 03/08/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 4/22/2022 04/22/2022
Misc
Informational
04/22/2022
third party inspection performed
Underslab Plumbing Inspection - Residential Passed 4/22/2022 4/22/2022 04/22/2022
Sewer Service Inspection - R Passed 5/12/2022 (1:00) 5/12/2022 05/12/2022
Water Service Inspection - R Passed 5/16/2022 (8:45) 5/16/2022 05/16/2022
Electrical Service Inspection Passed 12/15/2022 12/15/2022 12/15/2022
Gas Service Inspection - Residential Failed 12/15/2022 12/15/2022 12/15/2022
Misc
Corrective Action Required
12/15/2022
provide pressure at gas gauge minum 10psi.
All Rough Inspection - Residential Failed 12/15/2022 12/15/2022 12/15/2022
Misc
Corrective Action Required
12/15/2022
-complete portal frame nailing on exterior and top plate to header interior -nail off garage portals frame straps completely -anchor bolts to be in the middle 1/3 of sill plate -s3.0 7 in garage and 2nd floor -attic access in garage -furr down for return air in garage -connect bath vent in garage entry bath -missing hangers above pantry -fireblock into furr down in pantry -block along line for future cabinet furr down -missing nail in hanger above master near window -missing nails in hangers above master bath -address holes drilled closer than 2” to edge of joist above master shower -missing nails in hanger above master closet -sold block sheathing break top bed 4 closet -anchor all steel column in basement -complete R/a panning near furnace -missing double 2x10 in basement near N D column -provide pressure at gas gauge
All Rough Inspection - Residential Passed 12/29/2022 12/29/2022 12/29/2022
Misc
Resolved
12/29/2022
-anchor bolts to be in the middle 1/3 of sill plate -missing nails in hanger above master closet -anchor all steel column in basement -complete R/a panning near furnace -missing double 2x10 in basement near N D column -provide pressure at gas gauge
Gas Service Inspection - Residential Passed 12/29/2022 12/29/2022 12/29/2022
Misc
Resolved
12/29/2022
provide pressure at gas gauge minum 10psi.
Erosion Control Inspection Residential Failed 2/22/2023 02/22/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/22/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/22/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Driveway Inspection Partial 3/20/2023 3/20/2023 03/20/2023
Misc
Informational
03/20/2023
3-20-23 RH. Driveway is formed up and aggregate is placed and compacted. Approved to pour.
Driveway Inspection Passed 3/27/2023 3/27/2023 03/27/2023
Misc
Informational
03/20/2023
3-20-23 RH. Driveway is formed up and aggregate is placed and compacted. Approved to pour. 3-27-23 RH. Driveway meets LS specificaiton.
Piers/Caissons Inspection - Residential Passed 06/08/2023
Misc
Resolved
06/08/2023
-Provide arc fault protection for all kitchen outlets. See refrigerator -provide 14”-18” depth at water meter from meter top to well lid ring while maintaining meter lid flush with grade
Plot Plan Inspection Passed 06/08/2023
Erosion Control Inspection Residential Passed 06/08/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
06/08/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Resolved
06/08/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Occupancy Inspection - Codes Residential Failed 6/8/2023 6/8/2023 06/08/2023
Misc
Corrective Action Required
06/08/2023
-Provide arc fault protection for all kitchen outlets. See refrigerator -provide 14”-18” depth at water meter from meter top to well lid ring while maintaining meter lid flush with grade
Occupancy Inspection - Codes Residential Full C of O 6/13/2023 6/13/2023 06/13/2023
Misc
Resolved
06/13/2023
-provide 14”-18” depth at water meter from meter top to well lid ring while maintaining meter lid flush with grade
Documents & Images
Date Uploaded File Type Document Name
03/03/2022 3213 Saddlebred Signed Permit Application
03/08/2022 Plot Plan APPROVED PLOT PLAN
03/08/2022 Approved Plans APPROVED DRAWINGS
03/08/2022 Permit Codes Residential Plan Review
03/08/2022 Permit DS Building Permit
03/08/2022 Receipt Receipt for transaction:2022-001257
04/08/2022 Wilmoth 3213 SW Saddlebred Ter LSMO Summit View Farms Lot 114 Footing Inspection Report 4-7-22
04/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
05/12/2022 Letter INSPECTION SUMMARY
05/16/2022 Letter INSPECTION SUMMARY
10/03/2022 Letter Codes 140 Day Letter
12/07/2022 3213 SW Saddlebred Terr ROW
12/15/2022 Letter INSPECTION SUMMARY
12/15/2022 Letter INSPECTION SUMMARY
12/15/2022 Letter INSPECTION SUMMARY
12/29/2022 Letter INSPECTION SUMMARY
12/29/2022 Letter INSPECTION SUMMARY
02/22/2023 Letter INSPECTION SUMMARY
03/20/2023 Letter INSPECTION SUMMARY
03/27/2023 Letter INSPECTION SUMMARY
06/08/2023 3213 Saddlebred Pier inspection
06/08/2023 Letter INSPECTION SUMMARY
06/08/2023 Letter INSPECTION SUMMARY
06/08/2023 Letter INSPECTION SUMMARY
06/08/2023 Letter INSPECTION SUMMARY
06/13/2023 Letter Field Certificate of Occupancy
06/13/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home