Permit Application Status

PRRES20220755


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20220755
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. WALKOUT BASEMENT. FINISHED/UNFINISHED BASEMENT. COVERED DECK. ENGINEERD FLOOR SYSTEM - DEFERRED.
03/01/2022
03/04/2022
07/18/2023
Locations
Contacts
JFE CONSTRUCTION INC, Address:1314 SW MARKET ST, Phone:(816) 470-0074  
Angie Mendenhall, Address:1314 SW Market Street  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
PERMITTING@JFECONSTRUCTION.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $510.00 $510.00 Paid 03/04/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 03/04/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 03/04/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 03/04/2022
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 03/04/2022
9110078-Valuation Fee New Single Family $1,164.79 $1,164.79 Paid 03/04/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 4/25/2022 04/25/2022
Misc
Informational
04/25/2022
Third party inspection performed.
Underslab Plumbing Inspection - Residential Passed 5/12/2022 5/12/2022 05/12/2022
Sewer Service Inspection - R Passed 5/31/2022 (8:15) 5/31/2022 05/31/2022
Water Service Inspection - R Partial 5/31/2022 05/31/2022
Misc
Informational
05/31/2022
pex ran from foundation
Water Service Inspection - R Passed 6/1/2022 06/01/2022
Misc
Resolved
06/01/2022
pex ran from foundation
Miscellaneous Inspection Passed 10/20/2022 10/20/2022
Misc
Informational
10/20/2022
E-mail in request for permit extension. Mitchell Schwarz 10/20/2022 3:02 PM
Gas Service Inspection - Residential Passed 1/20/2023 1/20/2023 01/20/2023
Electrical Service Inspection Passed 1/20/2023 1/20/2023 01/20/2023
All Rough Inspection - Residential Failed 1/20/2023 1/20/2023 01/20/2023
Misc
Corrective Action Required
01/20/2023
-address studs for n garage over notched for anchor bolts -missing nails in hanger above laundry -fire block master bath walls to ceiling space where ceiling line is below top plates -address over notched hip rafter above master bedroom SW corner -strap top plate NW master bedroom corner where lapped less than 24” -seal penetrations in RA master/fireplace -address all studs over notched for anchor bolts in basement -anchor bolts to be within 12” of plate ends, not closer than 7x the diameter of the bolt -anchor bolts to be within the middle 1/3 of sill plate
All Rough Inspection - Residential Passed 1/26/2023 1/26/2023 01/26/2023
Misc
Resolved
01/26/2023
-address studs for n garage over notched for anchor bolts -missing nails in hanger above laundry -fire block master bath walls to ceiling space where ceiling line is below top plates -address over notched hip rafter above master bedroom SW corner -strap top plate NW master bedroom corner where lapped less than 24” -seal penetrations in RA master/fireplace -address all studs over notched for anchor bolts in basement -anchor bolts to be within 12” of plate ends, not closer than 7x the diameter of the bolt -anchor bolts to be within the middle 1/3 of sill plate
Driveway Inspection Partial 3/8/2023 3/8/2023 03/08/2023
Misc
Informational
03/08/2023
3-8-23 RH. Driveway is formed up and aggregate is placed and compacted. Approved to pour.
Driveway Inspection Passed 3/15/2023 3/15/2023 03/15/2023
Misc
Informational
03/08/2023
3-8-23 RH. Driveway is formed up and aggregate is placed and compacted. Approved to pour. 3-15-23 RH. Driveway meets LS and ADA specification.
Piers/Caissons Inspection - Residential Passed 7/10/2023 07/10/2023
Erosion Control Inspection Residential Passed 7/10/2023 07/10/2023
Plot Plan Inspection Passed 7/10/2023 07/10/2023
Occupancy Inspection - Codes Residential Failed 7/10/2023 7/10/2023 07/10/2023
Misc
Corrective Action Required
07/10/2023
-Counter top Outlet spacing at basement wet bar to be code compliant see figure E 3901.4.1 of the 2018 irc
Occupancy Inspection - Codes Residential Full C of O 7/18/2023 7/18/2023 07/18/2023
Misc
Resolved
07/18/2023
-Counter top Outlet spacing at basement wet bar to be code compliant see figure E 3901.4.1 of the 2018 irc
Documents & Images
Date Uploaded File Type Document Name
03/01/2022 HF51 - Permit App
03/01/2022 HF51 - Tax App
03/03/2022 Drawing APPROVED DRAWINGS
03/03/2022 Permit Codes Residential Plan Review
03/03/2022 Plot Plan APPROVED PLOT PLAN
03/04/2022 Permit DS Building Permit
03/04/2022 Receipt Receipt for transaction:2022-001157
04/24/2022 2822 SW Hearthstone Pl LSMO Retreat @ Hook Farms Lot 51 JFE P 2022-0755 3rd Party Footing Inspection Report 4-22-22
04/25/2022 Letter INSPECTION SUMMARY
05/12/2022 Letter INSPECTION SUMMARY
05/31/2022 Letter INSPECTION SUMMARY
05/31/2022 Letter INSPECTION SUMMARY
06/01/2022 Letter INSPECTION SUMMARY
06/09/2022 2822 SW Hearthstone Pl_ALL SLAB & DECK PIER INSP_2022-06-08
10/19/2022 Letter Codes 140 Day Letter
01/19/2023 Approved Plans APPROVED JOIST DRAWINGS
01/20/2023 Letter INSPECTION SUMMARY
01/20/2023 Letter INSPECTION SUMMARY
01/20/2023 Letter INSPECTION SUMMARY
01/20/2023 Letter INSPECTION SUMMARY
01/25/2023 Jan 25, Doc 1
01/25/2023 2822 SW Heatherstone Place_Framing Evaluation Report_1-25-23
01/26/2023 Letter INSPECTION SUMMARY
03/08/2023 Letter INSPECTION SUMMARY
03/15/2023 Letter INSPECTION SUMMARY
07/10/2023 Letter INSPECTION SUMMARY
07/10/2023 Letter INSPECTION SUMMARY
07/10/2023 Letter INSPECTION SUMMARY
07/10/2023 Letter INSPECTION SUMMARY
07/18/2023 Letter Field Certificate of Occupancy
07/18/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home