Summary
PRRES20220584
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
02/16/2022
02/23/2022
08/16/2022
06/23/2023
Locations
Contacts
WALKER CUSTOM HOMES, LLC, Address:PO BOX 3194, Phone:(913) 208-2026  
Jason walker, Address:PO Box 247, Phone:(913) 208-2026  
R-MECH HEATING COOLING PLUMBING/RHODES HEATING COOLING PLUMBING AND ROOTER, Address:1425 AGNES AVE, Phone:(816) 920-5955  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,190.93 $1,190.93 Paid 02/23/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 02/23/2022
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 02/23/2022
8331507-Sewer Connection Fee $510.00 $510.00 Paid 02/23/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 02/23/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 02/23/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 4/5/2022 04/05/2022
Underslab Plumbing Inspection - Residential Passed 4/25/2022 4/25/2022 04/25/2022
Sewer Service Inspection - R Passed 5/10/2022 (3:00) 5/10/2022 05/10/2022
Water Service Inspection - R Passed 5/12/2022 (1:00) 5/12/2022 05/12/2022
Gas Service Inspection - Residential Passed 10/20/2022 10/20/2022
Electrical Service Inspection Passed 10/20/2022 10/20/2022 10/20/2022
All Rough Inspection - Residential Failed 10/20/2022 10/20/2022
Misc
Corrective Action Required
10/20/2022
-nail top plate to header to design at garage portal frame -anchor bolts to be in the middle 1/3 of sill plate see throughout -fireblock S basement wall into furr down seal gaps -seal floor penetrations for unused hvac places -Seal furr down -support bath vent in ceiling space above bed 3 -fire block S bed 3 wall into furr down -address fastening of exterior sheathing plans call for nails you have staples
All Rough Inspection - Residential Failed 10/24/2022 10/24/2022 10/24/2022
Misc
Corrective Action Required
10/20/2022
-anchor bolts to be in the middle 1/3 of sill plate see throughout (see W garage wall and throughout garage)
All Rough Inspection - Residential Passed 10/25/2022 10/25/2022 10/25/2022
Misc
Resolved
10/25/2022
-anchor bolts to be in the middle 1/3 of sill plate see throughout (see W garage wall and throughout basement)
Driveway Inspection Partial 11/7/2022 11/7/2022 11/07/2022
Misc
Corrective Action Required
11/07/2022
11-7-22 RH. Driveway is formed up and aggregate is placed and compacted. Approved to pour.
Driveway Inspection Passed 11/14/2022 11/14/2022 11/14/2022
Misc
Corrective Action Required
11/07/2022
11-7-22 RH. Driveway is formed up and aggregate is placed and compacted. Approved to pour. 11-14-22 RH. Driveway meets LS specification.
Sidewalk Inspection Partial 3/20/2023 3/20/2023 03/20/2023
Misc
Informational
03/20/2023
3-20-23 RH. Sidewalk is formed up and aggregate is placed and compacted. Approved to pour.
Sidewalk Inspection Passed 3/27/2023 3/27/2023 03/27/2023
Misc
Informational
03/20/2023
3-20-23 RH. Sidewalk is formed up and aggregate is placed and compacted. Approved to pour. 3-27-22 RH. Sidewalk meets LS and ADA specification.
Sidewalk Inspection Passed 06/08/2023
Misc
Informational
03/27/2023
3-20-23 RH. Sidewalk is formed up and aggregate is placed and compacted. Approved to pour. 3-27-22 RH. Sidewalk meets LS and ADA specification.
Piers/Caissons Inspection - Residential Passed 06/08/2023
Plot Plan Inspection Passed 06/08/2023
Erosion Control Inspection Residential Passed 06/08/2023
Occupancy Inspection - Codes Residential Failed 6/8/2023 6/8/2023 06/08/2023
Misc
Corrective Action Required
06/08/2023
-Paint exterior gas line -provide 14”-18” depth at water meter from meter top to well lid ring while maintaining meter lid flush with grade
Occupancy Inspection - Codes Residential Full C of O 6/23/2023 6/23/2023 06/23/2023
Misc
Resolved
06/23/2023
-Paint exterior gas line -provide 14”-18” depth at water meter from meter top to well lid ring while maintaining meter lid flush with grade
Documents & Images
Date Uploaded File Type Document Name
02/16/2022 Lee's Summit Building App Filled Out
02/17/2022 Approved Plans Approved Drawings
02/17/2022 Permit Codes Residential Plan Review
02/22/2022 Plot Plan Approved Plot Plan
02/22/2022 Permit Codes Residential Plan Review
02/23/2022 Permit DS Building Permit
02/23/2022 Receipt Receipt for transaction:2022-000932
04/05/2022 Letter INSPECTION SUMMARY
04/06/2022 Wilmoth 3212 SW SW Saddlebred Ter LSMO Summit View Farms Lot 118 3rd Party Footing Inspection Report 4-5-22
04/06/2022 Wilmoth 3212 SW SW Saddlebred Ter LSMO Summit View Farms Lot 118 3rd Party Footing Inspection Report 4-5-22
04/25/2022 Letter INSPECTION SUMMARY
05/10/2022 Letter INSPECTION SUMMARY
05/12/2022 Letter INSPECTION SUMMARY
10/20/2022 Letter INSPECTION SUMMARY
10/20/2022 Letter INSPECTION SUMMARY
10/20/2022 Letter INSPECTION SUMMARY
10/24/2022 Letter INSPECTION SUMMARY
10/25/2022 Letter INSPECTION SUMMARY
11/07/2022 Letter INSPECTION SUMMARY
11/14/2022 Letter INSPECTION SUMMARY
12/07/2022 3212 Saddlebred Ter_ ROW
03/20/2023 Letter INSPECTION SUMMARY
03/27/2023 Letter INSPECTION SUMMARY
03/27/2023 Letter INSPECTION SUMMARY
06/08/2023 3212 Saddlebred Pier Inspection
06/08/2023 Letter INSPECTION SUMMARY
06/08/2023 Letter INSPECTION SUMMARY
06/08/2023 Letter INSPECTION SUMMARY
06/08/2023 Letter INSPECTION SUMMARY
06/08/2023 Letter INSPECTION SUMMARY
06/08/2023 Letter INSPECTION SUMMARY
06/23/2023 Letter Field Certificate of Occupancy
06/23/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home