Permit Application Status

PRRES20220521


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20220521
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. COVERED PATIO. ROOF TRUSSES.
02/10/2022
02/16/2022
08/14/2022
03/24/2023
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
LOREN@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Right of Way Permit Fee $85.00 $85.00 Paid 02/16/2022
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 02/16/2022
8331507-Sewer Connection Fee $600.00 $600.00 Paid 02/16/2022
Water Tap Fee $3,655.00 $3,655.00 Paid 02/16/2022
Valuation Fee New Single Family $1,362.02 $1,362.02 Paid 02/16/2022
Water Meter Fee $479.24 $479.24 Paid 02/16/2022
Not Ready Inspection Fee $50.00 $50.00 Paid 08/05/2022
3rd and Subsequent Inspection Fee (Per Hour) $75.00 $75.00 Paid 08/29/2022
Not Ready Inspection Fee $75.00 $75.00 Paid 08/30/2022
Temporary Occupancy Fee $50.00 $50.00 Paid 03/23/2023
Temporary Occupancy Fee $50.00 $50.00 Paid 03/23/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 3/31/2022 03/31/2022
DCM5 ESC INSP DENIED
Corrective Action Required
03/31/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/31/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Underslab Plumbing Inspection - Residential Not Ready 3/31/2022 3/31/2022 03/31/2022
Misc
Corrective Action Required
03/31/2022
Inspection denied -no address posted -no erosion control -backfill required to view underslab plumbing
Sewer Service Inspection - R Passed 4/7/2022 (9:30) 4/7/2022 04/07/2022
Water Service Inspection - R Passed 4/8/2022 (10:15) 4/8/2022 04/08/2022
Underslab Plumbing Inspection - Residential Passed 4/18/2022 4/18/2022 04/18/2022
Misc
Resolved
04/18/2022
Inspection denied -no address posted -no erosion control -backfill required to view underslab plumbing
All Rough Inspection - Residential Failed 8/5/2022 8/5/2022 08/05/2022
Misc
Corrective Action Required
08/05/2022
inspection denied no address posted
Electrical Service Inspection Passed 8/10/2022 8/10/2022 08/10/2022
Footing Inspection - Residential Passed 8/10/2022 08/10/2022
All Rough Inspection - Residential Failed 8/10/2022 8/10/2022 08/10/2022
Misc
Corrective Action Required
08/05/2022
inspection denied no address posted
Misc
Corrective Action Required
08/10/2022
-seal top plate penetrations at pfh -nail top plate to header per design at pfh -anchor bolts to be per design at pfh -seal furr out walls into furr down in garage -missing stud packs at GT bearing points in garage W wall -fireblock hvac chase into furr down in garage -fireblock dead space to ceiling space at garage entry -smoke combo outside bath 4 to be minimum 3’ from bathroom while remaining within immediate facility of bed 5 -fireblock W garage wall into furr down -complete duct above kitchen area near rear door -address over notched joist near plumbing chase above great room -fire block great room wall into furr down in great room -fireblock chases right and left of great room windows into furr down(seal gaps) -smokes in bed 3 and 4 to close to bath 3 -missing truss hanger above bed 2 -protect NM with 6’ of attic access -ufer ground rod connection to remain accessible -water shut off valve to remain accessible at time of water heater install -fire block basement stairwell walls vertically horizontally every 10’ -install gas in home -missing truss hangers at rear patio -missing truss hanger at front patio
All Rough Inspection - Residential Failed 8/22/2022 8/22/2022 08/22/2022
Misc
Resolved
08/22/2022
inspection denied no address posted
Misc
Corrective Action Required
08/10/2022
-seal top plate penetrations at pfh -seal furr out walls into furr down in garage (seal gaps) -missing stud packs at GT bearing points in garage W wall -fireblock dead space to ceiling space at garage entry -protect NM with 6’ of attic access -ufer ground rod connection to remain accessible -fire block basement stairwell walls vertically horizontally every 10’ seal gaps -missing truss hanger at front patio
All Rough Inspection - Residential Failed 8/25/2022 8/25/2022 08/25/2022
Misc
Resolved
08/25/2022
inspection denied no address posted
Misc
Corrective Action Required
08/22/2022
-missing stud pack garage w wall see bath 4 (3) 2x4 -fireblock dead space to ceiling space at garage entry seal gaps -ufer ground rod connection to remain accessible Okay to insulate do not cover any items in need of inspection
All Rough Inspection - Residential Not Ready 8/29/2022 8/29/2022 08/29/2022
Misc
Corrective Action Required
08/25/2022
-missing stud pack garage w wall see bath 4 (3) 2x4 under triple 2x10 -fireblock dead space to ceiling space at garage entry seal penetrations for wires -ufer ground rod connection to remain accessible Okay to insulate do not cover any items in need of inspection
Gas Service Inspection - Residential Passed 8/30/2022 8/30/2022 08/30/2022
All Rough Inspection - Residential Passed 8/30/2022 8/30/2022 08/30/2022
Misc
Resolved
08/30/2022
-missing stud pack garage w wall see bath 4 (3) 2x4 under triple 2x10 -fireblock dead space to ceiling space at garage entry seal penetrations for wires -ufer ground rod connection to remain accessible Okay to insulate do not cover any items in need of inspection
Driveway Inspection Passed 9/2/2022 9/2/2022 09/02/2022
Misc
Informational
09/02/2022
On Friday, 9-02-2022. I performed and passed a driveway for placement of concrete.
Sidewalk Inspection Passed 9/2/2022 9/2/2022 09/02/2022
Misc
Informational
09/02/2022
On Friday, 9-02-2022. I performed and passed sidewalk inspection for placement of concrete.
Plot Plan Inspection Passed 12/27/2022 12/27/2022
Occupancy Inspection - Codes Residential Ready for Temp CO 2/3/2023 2/3/2023 02/03/2023
Misc
Informational
12/27/2022
Ensure manhole remains uncovered from passed plot plan
Misc
Corrective Action Required
02/03/2023
-sod -splash blocks to extend 36” from foundation
Piers/Caissons Inspection - Residential Passed 03/02/2023
Occupancy Inspection - Codes Residential Ready for Temp CO 3/2/2023 3/2/2023 03/02/2023
Misc
Informational
02/03/2023
Ensure manhole remains uncovered from passed plot plan
Misc
Corrective Action Required
02/03/2023
-sod -splash blocks to extend 36” from foundation
Erosion Control Inspection Residential Passed 03/24/2023
DCM5 ESC INSP DENIED
Corrective Action Required
03/31/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
DCM3 ESC REQUIRED 2 DAY
Resolved
03/24/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Full C of O 3/24/2023 3/24/2023 03/24/2023
Misc
Resolved
03/24/2023
Ensure manhole remains uncovered from passed plot plan
Misc
Resolved
03/24/2023
-sod -splash blocks to extend 36” from foundation
Documents & Images
Date Uploaded File Type Document Name
02/10/2022 HT #150 - PERMIT APP
02/15/2022 Permit Codes Residential Plan Review
02/15/2022 Approved Plans APPROVED DRAWINGS
02/15/2022 Approved Plans APPROVED TRUSS PACKAGE
02/16/2022 Approved Plans APPROVED TRUSS LAYOUT
02/16/2022 Plot Plan APPROVED PLOT PLAN
02/16/2022 Permit Codes Residential Plan Review
02/16/2022 Permit DS Building Permit
02/16/2022 Receipt Receipt for transaction:2022-000856
03/21/2022 Approved Plans APPROVED UPDATED DRAWING
03/30/2022 150 Hawthorne Ridge FTNG
03/31/2022 Letter INSPECTION SUMMARY
03/31/2022 Letter INSPECTION SUMMARY
04/07/2022 Letter INSPECTION SUMMARY
04/08/2022 Letter INSPECTION SUMMARY
04/18/2022 Letter INSPECTION SUMMARY
08/05/2022 Letter INSPECTION SUMMARY
08/05/2022 Receipt Receipt for transaction:2022-006418
08/10/2022 Letter INSPECTION SUMMARY
08/10/2022 Letter INSPECTION SUMMARY
08/10/2022 Letter INSPECTION SUMMARY
08/11/2022 150 Hawthorne Ridge Field Letter
08/22/2022 Letter INSPECTION SUMMARY
08/22/2022 Letter INSPECTION SUMMARY
08/25/2022 Letter INSPECTION SUMMARY
08/29/2022 Receipt Receipt for transaction:2022-007049
08/29/2022 Letter INSPECTION SUMMARY
08/30/2022 Receipt Receipt for transaction:2022-007088
09/02/2022 Letter INSPECTION SUMMARY
09/02/2022 Letter INSPECTION SUMMARY
12/22/2022 Plot Plan APPROVED AS BUILT PLOT PLAN
12/27/2022 Letter INSPECTION SUMMARY
12/27/2022 Letter INSPECTION SUMMARY
12/27/2022 Letter INSPECTION SUMMARY
03/02/2023 Letter INSPECTION SUMMARY
03/23/2023 Certificate/License Codes Temporary Certificate of Occupancy
03/23/2023 Certificate/License Codes Temporary Certificate of Occupancy
03/23/2023 Receipt Receipt for transaction:2023-001644
03/24/2023 Letter INSPECTION SUMMARY
03/24/2023 Letter INSPECTION SUMMARY
03/24/2023 Letter Field Certificate of Occupancy
03/24/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home