Permit Application Status

PRRES20220450


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20220450
Building Permit - Residential
Certificate of Occupancy
TRUMARK HOMES LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED PATIO
02/07/2022
03/06/2022
02/17/2023
Locations
Contacts
TRUMARK HOMES, LLC, Address:424 SE MAXWELL DR, Phone:(816) 564-5613  
TRUMARK HOMES LLC, Address:508 NW MANOR DR  
MARK A YANCIK, Address:508 nw manor dr  
C.M. MOSE & SON, Address:6603 ROYAL ST BLDG E, Phone:(816) 781-4707  
IMPACT ELECTRICAL SOLUTIONS LLC, Address:14 ANCHOR DRIVE, Phone:(816) 674-9345  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Right of Way Permit Fee $85.00 $85.00 Paid 03/06/2022
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 03/06/2022
8331507-Sewer Connection Fee $390.00 $390.00 Paid 03/06/2022
Water Tap Fee $3,655.00 $3,655.00 Paid 03/06/2022
Water Meter Fee $479.24 $479.24 Paid 03/06/2022
Valuation Fee New Single Family $1,072.19 $1,072.19 Paid 03/06/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Passed 3/29/2022 3/29/2022 03/29/2022
Footing Inspection - Residential Passed 03/29/2022
Informational
03/29/2022
FOOTING APPROVED BY ENGINEER
Sewer Service Inspection - R Passed 5/5/2022 (2:00) 5/5/2022 05/05/2022
Erosion Control Inspection Residential Failed 5/10/2022 05/10/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/10/2022
DEFICIENT EROSION CONTROL INSTALLATION. PROVIDE MIN 3/4" GRAVEL AT LOT ENTRANCE. RESTORE EROSION CONTROL ALONG THE STREET NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Water Service Inspection - R Passed 5/10/2022 (1:00) 5/10/2022 05/10/2022
Erosion Control Inspection Residential Failed 6/30/2022 06/30/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/10/2022
DEFICIENT EROSION CONTROL INSTALLATION. RESTORE EROSION CONTROL ALONG THE STREET **NO FURTHER INSPECTION IF EROSION CONTROL IS NOT IN COMPLIANCE
Electrical Service Inspection Failed 6/30/2022 06/30/2022
Misc
Corrective Action Required
06/30/2022
-Install covers at SE connections to main breaker
Gas Service Inspection - Residential Failed 6/30/2022 06/30/2022
Misc
Corrective Action Required
06/30/2022
-Provide min ten psi test pressure
All Rough Inspection - Residential Failed 6/30/2022 06/30/2022
Misc
Corrective Action Required
06/30/2022
-Nail the CSPF wall siding to stud/header/rim joist per code; strap the inner side of portal opening -Provide full bearing under triple stud at garage/stoop wall -Nail strap at garage/entry wall intersection -Double up the attic access trimmer joists. (Access is more than 3ft from bearing support) -Strap master bedroom exterior wall to the great room wall -Seal the return air at master closet wall from roof; do the same for return air at foyer/closet wall -Fb floor penetration at trap; Fb wall plate penetrations by ducting -Strap top plate of hallway wall outside front bedroom to the entry wall -Provide min 1.5” of bearing for triple lvl beam at stair wall -Fb basement wall from soffit; Fb basement hallway and bedroom wall from fur down ceiling space (Fb top gap); Fb wall from joist at bedroom 5 closet and bathroom **OK TO INSULATE
Electrical Service Inspection Passed 7/11/2022 7/11/2022 07/11/2022
Misc
Resolved
07/11/2022
-Install covers at SE connections to main breaker
Gas Service Inspection - Residential Passed 7/11/2022 7/11/2022 07/11/2022
Misc
Resolved
07/11/2022
-Provide min ten psi test pressure
All Rough Inspection - Residential Failed 7/11/2022 7/11/2022 07/11/2022
Misc
Corrective Action Required
06/30/2022
-Seal the return air at master closet wall from roof **I can see gap around the duct attachment to the sheathing and gap between the sheathing and 2x6. Seal these gaps so that air is not drawn from the attic **OK TO INSULATE
All Rough Inspection - Residential Passed 7/13/2022 7/13/2022 07/13/2022
Misc
Resolved
07/13/2022
-Seal the return air at master closet wall from roof **I can see gap around the duct attachment to the sheathing and gap between the sheathing and 2x6. Seal these gaps so that air is not drawn from the attic **OK TO INSULATE
Piers/Caissons Inspection - Residential Passed 7/14/2022 (8:00) 7/14/2022 07/14/2022
Driveway Inspection Partial 8/29/2022 8/29/2022 08/29/2022
Misc
Informational
08/29/2022
8-29-22 AN forms are in place and aggregate is present and compacted
Sidewalk Inspection Partial 08/29/2022
Misc
Informational
08/29/2022
8-29-22 AN forms are in place and aggregate is present and compacted
Driveway Inspection Passed 8/31/2022 8/31/2022 09/06/2022
Misc
Informational
08/29/2022
8-29-22 AN forms are in place and aggregate is present and compacted 9-6-22 AN. Driveway looks good and meets Ada spec
Sidewalk Inspection Passed 8/31/2022 8/31/2022 09/06/2022
Misc
Informational
08/29/2022
8-29-22 AN forms are in place and aggregate is present and compacted 9-6-22 AN sidewalk looks good and meets Ada spec
Erosion Control Inspection Residential Passed 02/10/2023
DCM2 ESC DEFICIENT INSTALLATION
Resolved
02/10/2023
DEFICIENT EROSION CONTROL INSTALLATION. RESTORE EROSION CONTROL ALONG THE STREET **NO FURTHER INSPECTION IF EROSION CONTROL IS NOT IN COMPLIANCE
Occupancy Inspection - Codes Residential Failed 2/10/2023 2/10/2023 02/10/2023
Misc
Corrective Action Required
02/10/2023
-Approved as-graded plot plan is required -Raise AC min 3" off the ground -Fix grading at driveway and rear patio -Provide AFCI protection for all outlets required per NEC 210.12. (Dishwasher &disposal) -Receptacle at furnace switch shall be gfci-protected
Plot Plan Inspection Passed 2/14/2023 02/14/2023
Occupancy Inspection - Codes Residential Full C of O 2/17/2023 2/17/2023 02/17/2023
Misc
Resolved
02/17/2023
-Raise AC min 3" off the ground -Fix grading at driveway and rear patio -Provide AFCI protection for all outlets required per NEC 210.12. (Dishwasher &disposal) -Receptacle at furnace switch shall be gfci-protected
Documents & Images
Date Uploaded File Type Document Name
02/07/2022 SKM_C36822020708010
02/07/2022 SKM_C36822020708000
02/07/2022 Approved Plans Approved Drawings
02/07/2022 Plot Plan Approved Plot Plan
02/07/2022 Permit Codes Residential Plan Review
03/02/2022 M L Crose 4704 NE Pocono Cir LSMO Monticello Lot 34 Trumark P 2022-0450 3rd Party Footing Inspection Report 3-1-22
03/06/2022 Permit DS Building Permit
03/06/2022 Receipt Receipt for transaction:2022-001170
03/29/2022 Letter INSPECTION SUMMARY
03/29/2022 Letter INSPECTION SUMMARY
05/05/2022 Letter INSPECTION SUMMARY
05/10/2022 Letter INSPECTION SUMMARY
05/10/2022 Letter INSPECTION SUMMARY
06/30/2022 Letter INSPECTION SUMMARY
06/30/2022 Letter INSPECTION SUMMARY
06/30/2022 Letter INSPECTION SUMMARY
06/30/2022 Letter INSPECTION SUMMARY
07/11/2022 Letter INSPECTION SUMMARY
07/11/2022 Letter INSPECTION SUMMARY
07/11/2022 Letter INSPECTION SUMMARY
07/13/2022 Letter INSPECTION SUMMARY
07/14/2022 Letter INSPECTION SUMMARY
08/29/2022 Letter INSPECTION SUMMARY
08/29/2022 Letter INSPECTION SUMMARY
09/06/2022 Letter INSPECTION SUMMARY
09/06/2022 Letter INSPECTION SUMMARY
02/10/2023 Letter INSPECTION SUMMARY
02/10/2023 Letter INSPECTION SUMMARY
02/13/2023 Plot Plan APPROVED AS BUILT PLOT PLAN
02/14/2023 Letter INSPECTION SUMMARY
02/17/2023 Letter Field Certificate of Occupancy
02/17/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home