Summary
PRRES20220195
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - UNFINISHED BASMENT - COVERED PATIO
01/17/2022
01/19/2022
01/20/2023
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
CMH PARKS INC, Address:5000 CLAYTON RD  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $570.00 $570.00 Paid 01/19/2022
Right of Way Permit Fee $85.00 $85.00 Paid 01/19/2022
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 01/19/2022
Water Tap Fee $3,655.00 $3,655.00 Paid 01/19/2022
Water Meter Fee $479.24 $479.24 Paid 01/19/2022
Valuation Fee New Single Family $1,352.40 $1,352.40 Paid 01/19/2022
Not Ready Inspection Fee $50.00 $50.00 Paid 12/19/2022
Not Ready Inspection Fee $50.00 $50.00 Paid 12/19/2022
Outstanding Fees Amount Paid Owing Date Paid


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/9/2022 02/09/2022
Misc
Informational
02/09/2022
Ufer located as third party inspection report and plans indicate.
Water Service Inspection - R Partial 2/16/2022 02/16/2022
Sewer Service Inspection - R Passed 2/16/2022 (1:30) 2/16/2022 02/16/2022
Underslab Plumbing Inspection - Residential Not Ready 2/18/2022 2/18/2022 02/18/2022
Misc
Corrective Action Required
02/18/2022
inspection denied no address posted
Erosion Control Inspection Residential Failed 2/18/2022 02/18/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
02/22/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. REPAIR DOWNED SILT FENCE
Misc
Informational
02/22/2022
EROSION CONTROL BACK IN COMPLIANCE Mitchell Schwarz 02/22/2022 11:24 AM
Underslab Plumbing Inspection - Residential Not Ready 2/22/2022 2/22/2022 02/22/2022
Misc
Corrective Action Required
02/18/2022
inspection denied no address posted -still not posted Mitchell Schwarz 02/22/2022 11:23 AM
Water Service Inspection - R Passed 2/22/2022 (11:00) 2/22/2022 02/22/2022
Erosion Control Inspection Residential Partial 2/22/2022 02/22/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
02/22/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. REPAIR DOWNED SILT FENCE
Misc
Corrective Action Required
02/22/2022
EROSION CONTROL BACK IN COMPLIANCE Mitchell Schwarz 02/22/2022 11:25 AM
Underslab Plumbing Inspection - Residential Passed 3/24/2022 3/24/2022 03/24/2022
Misc
Resolved
03/24/2022
inspection denied no address posted -still not posted Mitchell Schwarz 02/22/2022 11:23 AM
Gas Service Inspection - Residential Passed 7/12/2022 7/12/2022 07/12/2022
Electrical Service Inspection Passed 7/12/2022 7/12/2022 07/12/2022
All Rough Inspection - Residential Failed 7/12/2022 7/12/2022 07/12/2022
Misc
Corrective Action Required
07/12/2022
-fireblock furr out into furr down in garage seal all penetrations into furr down and in top plate in this area -fire block hvac chase into furr down -furr down joist space with hvac for insulation -protect nm above service panel at top plate and thought as required by code -address over drilled stud for SE cable at panel -address over notched stud near service panel -all anchor bolts to be tight -seal top plate penetrations each side of garage portal frame -missing truss hold downs above single car garage -miss stud packs at gt bearing points in garage -stud packs at gt bearing points bath 1 N wall -address over board studs in bearing wall for bath 1 for dwv -seal penetrations from bath one into bed 1 furr down -seal penetrations from laundry and walk in closet to bed 1 furr down -gt stud packs bed 1 -cs-of bed 1 -uncover covered patio for inspection -complete cspf at great room windows -missing hold downs at gt truss above great room windows -missing hold downs at double truss near slider -uncover covered front porch for inspection -support ridge beam above front stoop -gt bearing stud pack at fridge -check all gt bearing points 2nd floor -top plate penetrations foyer/ powder room -address holes drilled closer than 2” to each other in floor joist above home office -missing lib bed 2 -seal top plate penetrations bed 2 and bath 2 -missing stud at hvac chase 2nd floor -provide attic access above bed 2 -seal top plate penetration bed 3 -strap top plate lapped less than 24” stairwell wall -address holes drilled closer than 2” to bottom of floor joist under kitchen island -address over bored floor joist for dwv near basement window -
All Rough Inspection - Residential Failed 8/1/2022 8/1/2022 08/01/2022
Misc
Corrective Action Required
07/12/2022
-address over notched stud near service panel -miss stud packs at gt bearing points in garage -cs-of bed 1 -uncover covered patio for inspection (secure all trussed per manufacture specs) -missing hold down at gt truss above great room windows -missing hold downs at double truss near slider -provide attic access above bed 2 -address holes drilled closer than 2” to bottom of floor joist under kitchen island -address over bored floor joist for dwv near basement window -
All Rough Inspection - Residential Failed 8/3/2022 8/3/2022 08/03/2022
Misc
Corrective Action Required
08/01/2022
-cs-pf bed 1 missing straps -uncover covered patio for inspection (secure all trussed per manufacture specs) hold downs not installed properly -provide attic access above bed 2(protect NM WIth in 6’ of this access)
All Rough Inspection - Residential Passed 8/8/2022 8/8/2022 08/08/2022
Misc
Resolved
08/08/2022
-cs-pf bed 1 missing straps -uncover covered patio for inspection (secure all trussed per manufacture specs) hold downs not installed properly -provide attic access above bed 2(protect NM WIth in 6’ of this access)
Driveway Inspection Partial 8/25/2022 8/25/2022 08/25/2022
Misc
Informational
08/25/2022
8-25-22 RH. Driveway was formed up and aggregate was placed and compacted.
Sidewalk Inspection Partial 8/26/2022 8/26/2022 08/26/2022
Misc
Informational
08/26/2022
8-26-22 RH. Sidewalk was formed up and aggregate was placed and compacted.
Driveway Inspection Passed 9/1/2022 9/1/2022 08/29/2022
Misc
Informational
08/25/2022
8-25-22 RH. Driveway was formed up and aggregate was placed and compacted.
Misc
Informational
08/29/2022
On Monday, 8-29-2022. I performed a visual inspection on a driveway and found it to pass city standards.
Sidewalk Inspection Passed 8/29/2022 08/29/2022
Misc
Informational
08/26/2022
8-26-22 RH. Sidewalk was formed up and aggregate was placed and compacted.
Misc
Informational
08/29/2022
On Monday, 8-29-2022. I performed a visual inspection of the existing sidewalk and found it to meet city standards.
Piers/Caissons Inspection - Residential Passed 12/19/2022 12/19/2022
Plot Plan Inspection Passed 12/19/2022 12/19/2022
Occupancy Inspection - Codes Residential Failed 12/19/2022 12/19/2022 12/19/2022
Misc
Corrective Action Required
12/19/2022
-pay all fees -sod -uncover covered manhole -provide correct permit address -splash blocks and sump pump discharge to extend 36” from foundation -Provide hardware for rear slider -spark ring for outlet above fireplace -provide ladder for egress window well to code -provide lockout for all hardwired appliances
Erosion Control Inspection Residential Passed 1/17/2023 01/17/2023
Misc
Corrective Action Required
02/22/2022
EROSION CONTROL BACK IN COMPLIANCE Mitchell Schwarz 02/22/2022 11:25 AM
Occupancy Inspection - Codes Residential Failed 1/17/2023 1/17/2023 01/17/2023
Misc
Corrective Action Required
12/19/2022
-uncover covered manhole
Occupancy Inspection - Codes Residential Full C of O 1/20/2023 1/20/2023 01/20/2023
Misc
Resolved
01/20/2023
-uncover covered manhole
Documents & Images
Date Uploaded File Type Document Name
01/17/2022 HT #123 - PERMIT APP
01/18/2022 Approved Plans APPROVED TRUSS LAYOUT
01/18/2022 Approved Plans APPROVED TRUSS PACKAGE
01/19/2022 Permit Codes Residential Plan Review
01/19/2022 Receipt Receipt for transaction:2022-000321
02/09/2022 123 Hawthorne Ridge FTNG
02/09/2022 Letter INSPECTION SUMMARY
02/16/2022 Letter INSPECTION SUMMARY
02/18/2022 Letter INSPECTION SUMMARY
02/18/2022 Letter INSPECTION SUMMARY
02/22/2022 Letter INSPECTION SUMMARY
02/22/2022 Letter INSPECTION SUMMARY
02/22/2022 Letter INSPECTION SUMMARY
02/23/2022 Letter INSPECTION SUMMARY
03/24/2022 Letter INSPECTION SUMMARY
04/12/2022 Application Form APPLICATION
04/12/2022 Approved Plans APPROVED PLANS
04/12/2022 Plot Plan APPROVED PLOT PLAN
04/12/2022 Letter DS Building Permit
07/12/2022 Letter INSPECTION SUMMARY
07/12/2022 Letter INSPECTION SUMMARY
07/12/2022 Letter INSPECTION SUMMARY
07/15/2022 123 Hawthorn Ridge Letter
08/02/2022 Letter INSPECTION SUMMARY
08/08/2022 Letter INSPECTION SUMMARY
08/08/2022 Letter INSPECTION SUMMARY
08/25/2022 Letter INSPECTION SUMMARY
08/26/2022 Letter INSPECTION SUMMARY
08/29/2022 Letter INSPECTION SUMMARY
08/29/2022 Letter INSPECTION SUMMARY
12/16/2022 LOT 123 ASBUILT
12/16/2022 Plot Plan APPROVED AS GRADED PLOT PLAN
12/19/2022 Letter INSPECTION SUMMARY
12/19/2022 Letter INSPECTION SUMMARY
12/19/2022 Letter INSPECTION SUMMARY
12/19/2022 Receipt Receipt for transaction:2022-009572
01/17/2023 Letter INSPECTION SUMMARY
01/17/2023 Letter INSPECTION SUMMARY
01/20/2023 Letter Codes Final Certificate of Occupancy
01/20/2023 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home