Permit Application Status

PRRES20220013


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20220013
Building Permit - Residential
Certificate of Occupancy
JCM DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK - UNCOVERED DECK - ROOF TRUSSES
01/03/2022
01/07/2022
07/03/2022
10/11/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
JCM DEVELOPMENT LLC, Address:1314 SW MARKET ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $360.00 $360.00 Paid 01/07/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 01/07/2022
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 01/07/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 01/07/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 01/07/2022
9110078-Valuation Fee New Single Family $994.39 $994.39 Paid 01/07/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 07/25/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 07/26/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 10/10/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Not Ready 2/10/2022 2/10/2022 02/10/2022
Misc
Corrective Action Required
02/10/2022
INSPECTION DENIED FOOTING POURED WITHOUT INSPECTION, THIRD PARTY INSPECTION REPORT REQUIRED TO BE UPLOADED TO PERMIT WITHIN 48 HOURS OF INSPECTION
Footing Inspection - Residential Failed 2/10/2022 2/10/2022 02/10/2022
Misc
Corrective Action Required
02/10/2022
FOOTING POURED WITHOUT INSPECTION, THIRD PARTY INSPECTION REPORT REQUIRED TO BE UPLOADED TO PERMIT WITHIN 48 HOURS OF INSPECTION
Footing Inspection - Residential Passed 2/14/2022 2/14/2022 02/14/2022
Misc
Informational
02/14/2022
APPROVED PER DAVID P AINSWORTH 1/24/22
Underslab Plumbing Inspection - Residential Failed 2/16/2022 2/16/2022 02/16/2022
Misc
Corrective Action Required
02/10/2022
WHERE BUILDING SEWER HAS CHANGE OF DIRECTION GREATER THAN 45 DEGREES A CLEANOUT SHALL BE INSTALLED AT THE CHANGE OF DIRECTION P3005.2.4
Erosion Control Inspection Residential Partial 2/16/2022 2/16/2022 02/16/2022
Misc
Corrective Action Required
02/16/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Underslab Plumbing Inspection - Residential Failed 2/23/2022 2/23/2022 02/23/2022
Misc
Corrective Action Required
02/16/2022
WHERE BUILDING SEWER HAS CHANGE OF DIRECTION GREATER THAN 45 DEGREES A CLEANOUT SHALL BE INSTALLED AT THE CHANGE OF DIRECTION P3005.2.4
Sewer Service Inspection - R Passed 2/28/2022 (11:15) 2/28/2022 02/28/2022
Underslab Plumbing Inspection - Residential Passed 3/1/2022 3/1/2022 03/01/2022
Misc
Resolved
03/01/2022
Water Service Inspection - R Passed 3/8/2022 (9:45) 3/8/2022 03/08/2022
Erosion Control Inspection Residential Failed 3/8/2022 3/8/2022 03/08/2022
Misc
Resolved
03/08/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/08/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Gas Service Inspection - Residential Passed 4/26/2022 4/26/2022 04/26/2022
Electrical Service Inspection Failed 4/26/2022 4/26/2022 04/26/2022
Misc
Corrective Action Required
04/26/2022
-Provide jumper from ground bar to neutral bar, or land CEE conductor at neutral bar
All Rough Inspection - Residential Failed 4/26/2022 4/26/2022 04/26/2022
Misc
Corrective Action Required
04/26/2022
-Anchor bolts within 12” of plate break -Stud shoe at service cable bore in load bearing wall -Provide truss screws at both plies of double trusses, hip truss at SW corner, at GT -Seal top plate penetrations single car bay -(2) anchor bolts at return panel single car bay -Anchor bolts at north garage wall -Seal top plate penetration at NE garage -Fur out 1.5” for R13 at dryer -Seal top plate penetration at laundry -Provide proper slope at vent in attic space at laundry, master bath etc. -Fireblock ceiling line at master bath/ laundry -Seal top plate penetrations master bath -Insulate behind shower master bath -Complete DWV master shower -Protect NM at SW corner master bed and under window multiple areas -Strap top plate at bed 3 -Secure pex at bath 2 shower -Complete dwv bath 2 shower -(4) studs at GT bearing at stairwell -Anchor column base at stairwell -Strap top plates at stairwell -Complete solid blocking at island joists -Provide missing jack and king studs at missing basement windows -Install windows in basement -Provide joist hangers at north wall below master -Provide jumper from ground bar to neutral bar or land CEE conductor at neutral bar -No deck inspection performed
All Rough Inspection - Residential Passed 4/29/2022 4/29/2022 04/29/2022
Misc
Resolved
04/29/2022
Electrical Service Inspection Passed 4/29/2022 4/29/2022 04/29/2022
Misc
Resolved
04/29/2022
-Provide jumper from ground bar to neutral bar, or land CEE conductor at neutral bar
Erosion Control Inspection Residential Passed 4/29/2022 4/29/2022 04/29/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
04/29/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Piers/Caissons Inspection - Residential Partial 5/2/2022 (8:45) 5/2/2022 05/02/2022
Misc
Corrective Action Required
05/02/2022
PARTIAL PIERS, (1) 24" X 36" FOR NW CORNER ROOF SUPPORT INSPECTED, (3) ADDITIONAL PIERS REQUIRED PER PLANS
Erosion Control Inspection Residential Partial 5/2/2022 5/2/2022 05/02/2022
Driveway Inspection Passed 6/2/2022 6/2/2022 06/21/2022
Misc
Informational
06/02/2022
On 6.2.2022 I performed a driveway inspection and pass the subgrade to pour concrete.
Misc
Informational
06/21/2022
On Tuesday, 6-21-2022. I performed a visual inspection of a existing driveway and found it passes city standards
Piers/Caissons Inspection - Residential Failed 7/14/2022 (2:00) 7/14/2022 07/14/2022
Misc
Corrective Action Required
05/02/2022
PARTIAL PIERS, (1) 24" X 36" FOR NW CORNER ROOF SUPPORT INSPECTED, (3) ADDITIONAL PIERS REQUIRED PER PLANS 3 additional piers need to be to width and depth
Piers/Caissons Inspection - Residential Partial 7/18/2022 (8:30) 7/18/2022 07/18/2022
Misc
Corrective Action Required
07/14/2022
PARTIAL PIERS, (1) 24" X 36" FOR NW CORNER ROOF SUPPORT INSPECTED, (3) ADDITIONAL PIERS REQUIRED PER PLANS 7/18/22 (3) additional piers inspected, ok to pour, the (2) pier at front west side of deck need to be 36" below grade for frost depth
Piers/Caissons Inspection - Residential Passed 7/18/2022 (1:00) 7/18/2022 07/18/2022
Misc
Resolved
07/18/2022
PARTIAL PIERS, (1) 24" X 36" FOR NW CORNER ROOF SUPPORT INSPECTED, (3) ADDITIONAL PIERS REQUIRED PER PLANS 7/18/22 (3) additional piers inspected, ok to pour, the (2) pier at front west side of deck need to be 36" below grade for frost depth
Occupancy Inspection - Codes Residential Failed 7/22/2022 7/22/2022 07/22/2022
Misc
Corrective Action Required
07/22/2022
-resolve outstanding inspection fee -submit as graded plot plan for review and approval -final grade and sod -splash blocks -install all cover plates and outlets -install rear deck door hardware -provide landing at deck stairs
Occupancy Inspection - Codes Residential Ready for Temp CO 7/26/2022 7/26/2022 07/26/2022
Misc
Corrective Action Required
07/22/2022
-submit as graded plot plan for review and approval -final grade and sod -splash blocks -provide landing at deck stairs
Occupancy Inspection - Codes Residential Temporary C of O 07/26/2022
Misc
Corrective Action Required
07/26/2022
-submit as graded plot plan for review and approval -final grade and sod -splash blocks -provide landing at deck stairs
Plot Plan Inspection Passed 8/30/2022 08/30/2022
Erosion Control Inspection Residential Passed 09/02/2022
Occupancy Inspection - Codes Residential Ready for Temp CO 9/2/2022 9/2/2022 09/02/2022
Misc
Resolved
09/02/2022
- driveway inspection pending
Driveway Inspection Passed 6/20/2022 6/20/2022 09/02/2022
Misc
Informational
06/02/2022
On 6.2.2022 I performed a driveway inspection and pass the subgrade to pour concrete.
Occupancy Inspection - Codes Residential Failed 9/6/2022 9/6/2022 09/06/2022
Misc
Corrective Action Required
09/06/2022
SPLASH BLOCKS, MIN 36" DISCHARGE FROM FOUNDATION, WITH SHORTER SPLASH BLOCKS EITHER REPLACE WITH LONGER BLOCKS OR ADD EXTENSIONS TO DOWNSPOUTS TO KICK SPLASH BLOCKS OUT FOR 36" DISCHARGE
Occupancy Inspection - Codes Residential Full C of O 10/11/2022 10/11/2022 10/11/2022
Misc
Resolved
10/11/2022
Documents & Images
Date Uploaded File Type Document Name
01/03/2022 CB #153 - PERMIT APPLICATION
01/04/2022 Approved Plans APPROVED PLANS
01/04/2022 Approved Plans APPROVED TRUSS LAYOUT
01/04/2022 Approved Plans APPROVED TRUSS PACKAGE
01/04/2022 Permit Codes Residential Plan Review
01/07/2022 Plot Plan APPROVED PLOT PLAN
01/07/2022 Permit Codes Residential Plan Review
01/07/2022 Permit DS Building Permit
01/07/2022 Receipt Receipt for transaction:2022-000121
02/10/2022 Letter INSPECTION SUMMARY
02/10/2022 Letter INSPECTION SUMMARY
02/11/2022 M L Crose 3546 SE Corbin Dr LSMO Cobey Creek Lot 153 Clayton Permit 2022-0013 Footing Inspection Report 1-24-22
02/14/2022 Letter INSPECTION SUMMARY
02/16/2022 Letter INSPECTION SUMMARY
02/16/2022 Letter INSPECTION SUMMARY
02/23/2022 Letter INSPECTION SUMMARY
02/28/2022 Letter INSPECTION SUMMARY
03/01/2022 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
03/22/2022 Letter INSPECTION SUMMARY
04/26/2022 Letter INSPECTION SUMMARY
04/26/2022 Letter INSPECTION SUMMARY
04/26/2022 Letter INSPECTION SUMMARY
04/29/2022 Letter INSPECTION SUMMARY
04/29/2022 Letter INSPECTION SUMMARY
04/29/2022 Letter INSPECTION SUMMARY
05/02/2022 Letter INSPECTION SUMMARY
05/02/2022 Letter INSPECTION SUMMARY
06/02/2022 Letter INSPECTION SUMMARY
06/21/2022 Letter INSPECTION SUMMARY
06/21/2022 Letter INSPECTION SUMMARY
07/14/2022 Letter INSPECTION SUMMARY
07/18/2022 Letter INSPECTION SUMMARY
07/18/2022 Letter INSPECTION SUMMARY
07/22/2022 Letter INSPECTION SUMMARY
07/25/2022 Receipt Receipt for transaction:2022-006042
07/26/2022 Receipt Receipt for transaction:2022-006125
07/26/2022 Letter Codes Temporary Certificate of Occupancy
08/29/2022 Plot Plan APPROVED AS GRADED PLOT PLAN
08/30/2022 Letter INSPECTION SUMMARY
09/02/2022 Letter INSPECTION SUMMARY
09/02/2022 Letter INSPECTION SUMMARY
09/06/2022 Letter INSPECTION SUMMARY
10/10/2022 Certificate/License Codes Temporary Certificate of Occupancy
10/10/2022 Receipt Receipt for transaction:2022-008132
10/11/2022 Letter Field Certificate of Occupancy
10/11/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home