Permit Application Status

PRRES20216495


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20216495
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE. FINISHED BASEMENT. COVERED DECK. STOP WORK ORDER generated on 03/04/2022 12:00 AM by username 'Michael Harkins'. STOP WORK ORDER removed on 03/09/2022 12:00 AM by username 'Michael Harkins'.
12/27/2021
02/14/2022
06/27/2022
06/23/2023
Locations
Contacts
TRUMARK HOMES, LLC, Address:PO BOX 728, Phone:(816) 564-5613  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
MARK A YANCIK, Address:508 nw manor dr  
C.M. MOSE & SON, Address:6603 ROYAL ST BLDG E, Phone:(816) 781-4707  
IMPACT ELECTRICAL SOLUTIONS LLC, Address:14 ANCHOR DRIVE, Phone:(816) 674-9345  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
TRUMARKHOMES.MARK@GMAIL.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $510.00 $510.00 Paid 01/15/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 01/15/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 01/15/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 01/15/2022
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 01/15/2022
9110078-Valuation Fee New Single Family $1,124.97 $1,124.97 Paid 01/15/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 03/06/2022
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 04/04/2022
Outstanding Fees Amount Paid Owing Date Paid


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Failed 2/16/2022 2/16/2022 02/16/2022
Misc
Corrective Action Required
02/16/2022
inspection denied -erosion control not in compliance -footing poured without inspection
Erosion Control Inspection Residential Failed 2/16/2022 02/16/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/16/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
02/16/2022
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Erosion Control Inspection Residential Failed 3/4/2022 03/04/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/16/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
02/16/2022
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/04/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN GRAVEL FILTER WITH AGGREGATE SHALL BE MINIMUM OF 6" OF 3/4 INCH DIAMETER OR LARGER
Underslab Plumbing Inspection - Residential Not Ready 3/4/2022 3/4/2022 03/04/2022
Misc
Corrective Action Required
02/16/2022
inspection denied -erosion control not in compliance -footing poured without inspection
Misc
Corrective Action Required
03/04/2022
INSPECTION DENIED NO FOOTING INSPECTION ON RECORD
Footing Inspection - Residential Failed - Stop Work 3/4/2022 03/04/2022
Miscellaneous Correction
Corrective Action Required
03/04/2022
NO FOOTING INSPECTION ON RECORD SUBMIT 3RD PARTY INSPECTIONS WITHIN 48 HOURS OF POUR
Footing Inspection - Residential Passed 3/9/2022 03/09/2022
Miscellaneous Correction
Resolved
03/09/2022
3RD PARTY FOOTING BY DEREK PEREZ @ EVERSTEAD SIGNED & SEALED BY BRADLEY HUXOL UFER LOCATED UNDER FRONT STOOP
Underslab Plumbing Inspection - Residential Failed 3/11/2022 3/11/2022 03/11/2022
Misc
Resolved
03/11/2022
inspection denied -erosion control not in compliance -footing poured without inspection
Misc
Resolved
03/11/2022
INSPECTION DENIED NO FOOTING INSPECTION ON RECORD
Misc
Corrective Action Required
03/11/2022
DWV cover with snow
Underslab Plumbing Inspection - Residential Passed 3/16/2022 3/16/2022 03/16/2022
Misc
Resolved
03/16/2022
Sewer Service Inspection - R Passed 3/17/2022 (1:00) 3/17/2022 03/17/2022
Water Service Inspection - R Failed 4/1/2022 (1:15) 4/1/2022 04/01/2022
Miscellaneous Correction
Corrective Action Required
04/01/2022
PROVIDE MIN 10' COPPER LINE FROM METER TO HOUSE
Water Service Inspection - R Passed 4/4/2022 (11:15) 4/4/2022 04/04/2022
Miscellaneous Correction
Resolved
04/04/2022
Piers/Caissons Inspection - Residential Failed 5/17/2022 (8:00) 5/17/2022 05/17/2022
Misc
Corrective Action Required
05/17/2022
Inspected one 18” pier. Revise plans to show covered patio instead of deck. Okay to pour
Erosion Control Inspection Residential Failed 05/19/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/04/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
03/04/2022
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/04/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN GRAVEL FILTER WITH AGGREGATE SHALL BE MINIMUM OF 6" OF 3/4 INCH DIAMETER OR LARGER
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
05/19/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. PROVIDE SILT FENCE MAINTAIN GRAVEL FILTER CLEAN STREET
All Rough Inspection - Residential Failed 5/19/2022 5/19/2022 05/19/2022
Miscellaneous Correction
Corrective Action Required
05/19/2022
INSPECTION DENIED NO EROSION CONTROL ( SILT FENCE )
Gas Service Inspection - Residential Passed 5/24/2022 5/24/2022 05/24/2022
Electrical Service Inspection Failed 5/24/2022 5/24/2022 05/24/2022
Miscellaneous Correction
Corrective Action Required
05/24/2022
Not bonded to UFER Provide #4 jumper from grounding bus to neutral bus
Erosion Control Inspection Residential Failed 5/24/2022 5/24/2022 05/24/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
05/24/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
05/24/2022
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
DCM2 ESC DEFICIENT INSTALLATION
Resolved
05/24/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN GRAVEL FILTER WITH AGGREGATE SHALL BE MINIMUM OF 6" OF 3/4 INCH DIAMETER OR LARGER
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
05/19/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. 5/24/22 PROVIDE SILT FENCE installed on low side of lot MAINTAIN GRAVEL FILTER CLEAN STREET
All Rough Inspection - Residential Failed 5/24/2022 5/24/2022 05/24/2022
Miscellaneous Correction
Resolved
05/24/2022
INSPECTION DENIED NO EROSION CONTROL ( SILT FENCE )
Miscellaneous Correction
Corrective Action Required
05/24/2022
- Install all windows (sitting in garage) - Install all doors - Provide joist hangers at attic access - Address cut studs in back corner of double garage - Purlin strut to be 4’ OC - Fire block entry hall to master bedroom from great room - Security blocking at sliding door - Address single 2x6 upright supporting a triple 24” LVL with a gap offset in kitchen wall - Provide ladder to see porch roof framing - Address gap at top of all 2x6 studs at fire place wall not Bering on rafter - Strap corners at top plate entry to return wall - Provide stud under ridge front porch - Solid block sheeting breaks below window at stairs landing - Fire block penetration at top of electrical panel - Anchor bolts to be in middle 1/3 of plate basement around I beam and furnace - Fire block top plate bedroom 2 and bathroom in basement - Fire block top plate bedroom 3 exterior wall gaps - Fire block RA bedroom 4 basement - Nail all exterior sheeting to code
Electrical Service Inspection Passed 5/26/2022 05/26/2022
Miscellaneous Correction
Resolved
05/26/2022
All Rough Inspection - Residential Passed 5/26/2022 5/26/2022 05/31/2022
Miscellaneous Correction
Resolved
05/31/2022
Driveway Inspection Partial 7/21/2022 07/21/2022
Misc
Informational
07/21/2022
Driveway was framed up with aggregate in and compacted. 7/21/22 ES
Driveway Inspection Passed 7/29/2022 7/29/2022 08/02/2022
Misc
Informational
07/21/2022
Driveway was framed up with aggregate in and compacted. 7/21/22 ES Driveway meets LS spec. 8/2/22 ES
Plot Plan Inspection Passed 1/23/2023 01/23/2023
Erosion Control Inspection Residential Passed 2/8/2023 02/08/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
02/08/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. 5/24/22 PROVIDE SILT FENCE installed on low side of lot MAINTAIN GRAVEL FILTER CLEAN STREET
Occupancy Inspection - Codes Residential Failed 2/8/2023 2/8/2023 02/08/2023
Misc
Corrective Action Required
02/08/2023
- Garage stairs guard at bottom of spindles - Provide 6” clearance from siding to grade - Secure electrical whip at water heater - No Pier inspection on covered patio
Occupancy Inspection - Codes Residential Full C of O 6/23/2023 6/23/2023 06/23/2023
Misc
Resolved
06/23/2023
Documents & Images
Date Uploaded File Type Document Name
12/27/2021 SKM_C36821122716510
12/27/2021 SKM_C36821122716500
12/27/2021 107 Woodside Ridge added Ret wall
12/28/2021 Approved Plans APPROVED DRAWINGS
12/29/2021 Permit Codes Residential Plan Review
01/01/2022 Yancik 101 Ambersham LSMO Plan 3709LA Rev Submittal 12-30-21
01/03/2022 Plot Plan APPROVED PLOT PLAN
01/06/2022 Permit Codes Residential Plan Review
01/15/2022 Receipt Receipt for transaction:2022-000283
02/16/2022 Letter INSPECTION SUMMARY
02/16/2022 Letter INSPECTION SUMMARY
03/04/2022 Letter INSPECTION SUMMARY
03/04/2022 Letter INSPECTION SUMMARY
03/04/2022 Letter Stop Work Order
03/06/2022 Receipt Receipt for transaction:2022-001172
03/08/2022 107 Woodside Ridge FTNG
03/09/2022 Letter INSPECTION SUMMARY
03/11/2022 Letter INSPECTION SUMMARY
03/16/2022 Letter INSPECTION SUMMARY
03/17/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
04/04/2022 Receipt Receipt for transaction:2022-001839
04/04/2022 Letter INSPECTION SUMMARY
05/17/2022 Letter INSPECTION SUMMARY
05/19/2022 Letter INSPECTION SUMMARY
05/19/2022 Letter INSPECTION SUMMARY
05/24/2022 Letter INSPECTION SUMMARY
05/24/2022 Letter INSPECTION SUMMARY
05/24/2022 Letter INSPECTION SUMMARY
05/24/2022 Letter INSPECTION SUMMARY
05/26/2022 Letter INSPECTION SUMMARY
05/26/2022 Letter INSPECTION SUMMARY
05/31/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
12/20/2022 Letter Codes 140 Day Letter
01/20/2023 Plot Plan APPROVED AS GRADED PLOT PLAN
01/20/2023 Approved Plans APPROVED DECK TO PATIO PLAN CHANGE
01/23/2023 Letter INSPECTION SUMMARY
02/08/2023 Letter INSPECTION SUMMARY
02/08/2023 Letter INSPECTION SUMMARY
06/23/2023 Letter Codes Final Certificate of Occupancy
06/23/2023 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home