Permit Application Status

PRRES20216421


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20216421
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE. ROOF TRUSSES. UNFINISHED BASEMENT. COVERED DECK.
12/17/2021
12/29/2021
06/20/2022
12/19/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
LOREN@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $450.00 $450.00 Paid 12/29/2021
Water Tap Fee $3,655.00 $3,655.00 Paid 12/29/2021
Water Meter Fee $479.24 $479.24 Paid 12/29/2021
Right of Way Permit Fee $85.00 $85.00 Paid 12/29/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 12/29/2021
Valuation Fee New Single Family $1,234.43 $1,234.43 Paid 12/29/2021
Not Ready Inspection Fee $50.00 $50.00 Paid 12/05/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 1/14/2022 (11:00) 1/14/2022 01/14/2022
Misc
Informational
01/14/2022
deck pads poured
Water Service Inspection - R Passed 1/26/2022 (8:30) 1/26/2022 01/26/2022
Sewer Service Inspection - R Passed 1/26/2022 (8:30) 1/26/2022 01/26/2022
Underslab Plumbing Inspection - Residential Passed 2/9/2022 2/9/2022 02/09/2022
All Rough Inspection - Residential Not Ready 6/29/2022 6/29/2022 06/29/2022
Misc
Corrective Action Required
06/29/2022
inspection denied no gravel filter
Gas Service Inspection - Residential Failed 6/29/2022 6/29/2022 06/29/2022
Misc
Corrective Action Required
06/29/2022
inspection denied no gravel filter
Electrical Service Inspection Failed 6/29/2022 6/29/2022 06/29/2022
Misc
Corrective Action Required
06/29/2022
inspection denied no gravel filter
Erosion Control Inspection Residential Failed 6/29/2022 06/29/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/29/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. provide gravel filter
All Rough Inspection - Residential Failed 7/1/2022 7/1/2022 07/01/2022
Misc
Resolved
07/01/2022
inspection denied no gravel filter
Misc
Corrective Action Required
07/01/2022
NO FURTHER INSPECTIONS UNTIL EROSION CONTROL IS IN COMPLIANCE AND ADDRESS IS LEDGIBLE -missing lib in garage -furr out and down for dwv in garage -fire block into furr down in garage -address lib in kitchen cut -seal top plate penetration pantry/kitchen -fire block hvac chases left and right of great room windows into furr down -seal top plate penetrations at fireplace -install blocking at front stairwell window per plans -missing multiple truss hangers throughout -check lateral bracing at time of re inspection -address hole drilled closer than 2” to top of lvl for NM see basement stairs -hangers for all floor joists required near service panel as required by code -connect ufer ground to middle grounded bus bar -solid block under kitchen island to plans (one joist bay past each side -address over notched studs in basement
Gas Service Inspection - Residential Passed 7/1/2022 7/1/2022 07/01/2022
Misc
Resolved
07/01/2022
inspection denied no gravel filter
Erosion Control Inspection Residential Failed 7/1/2022 07/01/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
07/01/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. provide gravel filter
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
07/01/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Electrical Service Inspection Failed 7/1/2022 7/1/2022 07/01/2022
Misc
Resolved
07/01/2022
inspection denied no gravel filter
Misc
Corrective Action Required
07/01/2022
Connect ufer ground to middle grounded bus bar
All Rough Inspection - Residential Failed 7/12/2022 7/12/2022 07/12/2022
Misc
Corrective Action Required
07/01/2022
-maintain gravel filter on drive, min 6" lift required -furr out and down for dwv in garage, (2x6's NEEDED ON CEILING FUR DOWNS FOR R-19 INSULATION) -address lib in kitchen cut, (2 NAILS EACH STUD/PLATE STRAPS) -missing multiple truss hangers throughout (NOT DONE) -All truss lateral bracing per plans -address hole drilled closer than 2” to top of lvl for NM see basement stairs (NOT ADDRESSED) -Provide jumper from ground bar to neutral bar or land CEE on neutral bar
Electrical Service Inspection Failed 7/12/2022 7/12/2022 07/12/2022
Misc
Corrective Action Required
07/01/2022
E3607.5 SYSTEM GROUNDING. An unspliced main bonding jumper shall be used to connect the equipment grounding conductor(s) and the service-disconnect enclosure to the grounded conductor of the system within the enclosure for each service disconnect. -Provide jumper from ground bar to neutral bar or land CEE on neutral bar
Erosion Control Inspection Residential Failed 7/12/2022 7/12/2022 07/12/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
07/12/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Misc
Corrective Action Required
07/12/2022
MAINTAIN GRAVEL FILTER ON DRIVE, MIN 6" LIFT REQUIRED
All Rough Inspection - Residential Passed 8/1/2022 8/1/2022 08/01/2022
Misc
Resolved
08/01/2022
-missing multiple truss hangers throughout (NOT DONE) -All truss lateral bracing per plans -address hole drilled closer than 2” to top of lvl for NM see basement stairs (NOT ADDRESSED) -Provide jumper from ground bar to neutral bar or land CEE on neutral bar
Driveway Inspection Partial 8/4/2022 08/04/2022
Misc
Informational
08/04/2022
8-4-22 RH. Driveway was formed up and aggregate was placed and compacted.
Sidewalk Inspection Partial 8/4/2022 08/04/2022
Misc
Informational
08/04/2022
8-4-22 RH. Sidewalk was formed up and aggregate was placed and compacted.
Electrical Service Inspection Failed 8/5/2022 8/5/2022 08/05/2022
Misc
Corrective Action Required
07/12/2022
E3607.5 SYSTEM GROUNDING. An unspliced main bonding jumper shall be used to connect the equipment grounding conductor(s) and the service-disconnect enclosure to the grounded conductor of the system within the enclosure for each service disconnect. -Provide jumper from ground bar to neutral bar or land CEE on neutral bar
Misc
Corrective Action Required
08/05/2022
inspection denied no address posted
Electrical Service Inspection Passed 8/8/2022 8/8/2022 08/08/2022
Misc
Resolved
08/08/2022
E3607.5 SYSTEM GROUNDING. An unspliced main bonding jumper shall be used to connect the equipment grounding conductor(s) and the service-disconnect enclosure to the grounded conductor of the system within the enclosure for each service disconnect. -Provide jumper from ground bar to neutral bar or land CEE on neutral bar
Misc
Resolved
08/08/2022
inspection denied no address posted
Driveway Inspection Passed 8/12/2022 8/12/2022 08/15/2022
Misc
Informational
08/04/2022
8-4-22 RH. Driveway was formed up and aggregate was placed and compacted. 8-15-22 RH. Driveway passed LS and ADA specification.
Sidewalk Inspection Passed 8/12/2022 8/12/2022 08/15/2022
Misc
Informational
08/04/2022
8-4-22 RH. Sidewalk was formed up and aggregate was placed and compacted. 8-15-22 RH. Sidewalk passes LS and ADA specification.
Piers/Caissons Inspection - Residential Passed 12/2/2022 12/02/2022
Occupancy Inspection - Codes Residential Failed 12/2/2022 12/2/2022 12/02/2022
Misc
Corrective Action Required
12/02/2022
-sod -splash blocks and sump pump discharge to extend 36” from foundation -provide as graded plot plan -pay all fees -guard rail at front stoop, where as required by code -garage door to be self closing and LATCHING -security screws at rear deck door -deck stairs greater than 3/8” difference in rise (see bottom step)
Erosion Control Inspection Residential Passed 12/19/2022 12/19/2022
Misc
Resolved
12/19/2022
MAINTAIN GRAVEL FILTER ON DRIVE, MIN 6" LIFT REQUIRED
Plot Plan Inspection Passed 12/19/2022 12/19/2022
Occupancy Inspection - Codes Residential Full C of O 12/19/2022 12/19/2022 12/19/2022
Misc
Resolved
12/19/2022
-sod -splash blocks and sump pump discharge to extend 36” from foundation -provide as graded plot plan -pay all fees -guard rail at front stoop, where as required by code -garage door to be self closing and LATCHING -security screws at rear deck door -deck stairs greater than 3/8” difference in rise (see bottom step)
Documents & Images
Date Uploaded File Type Document Name
12/17/2021 LOT 130 FINAL
12/17/2021 H4 #130 - PERMIT APPLICATION
12/22/2021 Approved Plans APPROVED DRAWINGS
12/22/2021 Approved Plans APPROVED TRUSS PACKAGE
12/22/2021 Approved Plans APPROVED TRUSS LAYOUT
12/22/2021 Permit Codes Residential Plan Review
12/29/2021 SKM_C36821122915031
12/29/2021 Permit Codes Residential Plan Review
12/29/2021 Permit DS Building Permit
12/29/2021 Receipt Receipt for transaction:2021-009557
01/14/2022 Letter INSPECTION SUMMARY
01/26/2022 Letter INSPECTION SUMMARY
01/26/2022 Letter INSPECTION SUMMARY
02/09/2022 Letter INSPECTION SUMMARY
06/29/2022 Letter INSPECTION SUMMARY
06/29/2022 Letter INSPECTION SUMMARY
06/29/2022 Letter INSPECTION SUMMARY
06/29/2022 Letter INSPECTION SUMMARY
07/01/2022 Letter INSPECTION SUMMARY
07/01/2022 Letter INSPECTION SUMMARY
07/01/2022 Letter INSPECTION SUMMARY
07/01/2022 Letter INSPECTION SUMMARY
07/12/2022 Letter INSPECTION SUMMARY
07/12/2022 Letter INSPECTION SUMMARY
07/12/2022 Letter INSPECTION SUMMARY
07/22/2022 130 hawthorne ridge letter #2
08/01/2022 Letter INSPECTION SUMMARY
08/01/2022 Letter INSPECTION SUMMARY
08/04/2022 Letter INSPECTION SUMMARY
08/04/2022 Letter INSPECTION SUMMARY
08/05/2022 Letter INSPECTION SUMMARY
08/08/2022 Letter INSPECTION SUMMARY
08/15/2022 Letter INSPECTION SUMMARY
08/15/2022 Letter INSPECTION SUMMARY
12/02/2022 Letter INSPECTION SUMMARY
12/02/2022 Letter INSPECTION SUMMARY
12/05/2022 Receipt Receipt for transaction:2022-009259
12/06/2022 Plot Plan APPROVED AS BUILT PLOT PLAN
12/19/2022 Letter INSPECTION SUMMARY
12/19/2022 Letter INSPECTION SUMMARY
12/19/2022 Letter Field Certificate of Occupancy
12/19/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home