Permit Application Status

PRRES20216205


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20216205
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - UNFINISHED BASEMENT - COVERED PATIO
12/02/2021
12/06/2021
09/07/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331504-EFHB Middle Big Creek, Full $703.08 $703.08 Paid 12/06/2021
8331507-Sewer Connection Fee $630.00 $630.00 Paid 12/06/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 12/06/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 12/06/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 12/06/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 12/06/2021
9110078-Valuation Fee New Single Family $1,456.54 $1,456.54 Paid 12/06/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 1/3/2022 1/3/2022 01/03/2022
Misc
Informational
01/03/2022
APPROVED PER BRADLEY HUXOL 12/29/21
Underslab Plumbing Inspection - Residential Passed 1/25/2022 1/25/2022 01/25/2022
Sewer Service Inspection - R Passed 2/22/2022 (8:15) 2/22/2022 02/22/2022
Water Service Inspection - R Partial 2/22/2022 2/22/2022 02/22/2022
Water Service Inspection - R Passed 2/22/2022 (11:30) 2/22/2022 02/22/2022
Electrical Service Inspection Passed 5/23/2022 5/23/2022 05/23/2022
All Rough Inspection - Residential Failed 5/23/2022 5/23/2022 05/23/2022
Misc
Corrective Action Required
05/23/2022
-nail 3” oc garage PFH sheathing to blocking at sheathing splice portal leg -fireblock radon rim joist penetration garage -provide anchor bolts sgl car garage door wall -seal all top plate penetrations garage -fireblock vertical to horizontal at furred down soffit line garage wall -provide (2) nails each stud/plate LIB straps -Fireblock all tub traps -protect NM within 6’ of attic entry -fireblock HVAC chase pantry -provide protection plate bottom plate pex kitchen for fridge -install back door -seal gas line floor penetration at fireplace -complete all bath exhaust fan ducts -unable to inspect truss hangers at covered porch with lid installed -provide all truss hangers per plans -fireblock HVAC chase master bath -nail joist hanger above furnace -anchor all SCH 40 steel columns to floor at basement -gas pressure 0 psi must maintain 10 psi for test
Gas Service Inspection - Residential Failed 5/23/2022 5/23/2022 05/23/2022
Misc
Corrective Action Required
05/23/2022
-gas pressure 0 psi must maintain 10 psi for test
Erosion Control Inspection Residential Partial 5/23/2022 05/23/2022
Erosion Control Inspection Residential Failed 5/26/2022 05/26/2022
Misc
Corrective Action Required
05/26/2022
-Maintain gravel filter with min 6" lift of min 3/4" gravel -Clean debris from streets -Clean trash from lot
Gas Service Inspection - Residential Passed 5/26/2022 5/26/2022 05/26/2022
Misc
Resolved
05/26/2022
-gas pressure 0 psi must maintain 10 psi for test
All Rough Inspection - Residential Passed 5/26/2022 5/26/2022 05/26/2022
Misc
Resolved
05/26/2022
-nail 3” oc garage PFH sheathing to blocking at sheathing splice portal leg -fireblock radon rim joist penetration garage -provide anchor bolts sgl car garage door wall -seal all top plate penetrations garage -fireblock vertical to horizontal at furred down soffit line garage wall -provide (2) nails each stud/plate LIB straps -Fireblock all tub traps -protect NM within 6’ of attic entry -fireblock HVAC chase pantry -provide protection plate bottom plate pex kitchen for fridge -install back door -seal gas line floor penetration at fireplace -complete all bath exhaust fan ducts -unable to inspect truss hangers at covered porch with lid installed -provide all truss hangers per plans -fireblock HVAC chase master bath -nail joist hanger above furnace -anchor all SCH 40 steel columns to floor at basement -gas pressure 0 psi must maintain 10 psi for test
Driveway Inspection Partial 6/21/2022 6/21/2022 06/21/2022
Misc
Informational
06/21/2022
On 6/21/2022 I performed a driveway inspection and pass the sub grade to pour concrete.
Sidewalk Inspection Partial 6/21/2022 6/21/2022 06/21/2022
Misc
Informational
06/21/2022
On 6/21/2022 I performed a sidewalk inspection and pass the sub grade to pour concrete with dowels into the existing concrete to reduce expansion.
Piers/Caissons Inspection - Residential Passed 9/2/2022 09/02/2022
Misc
Informational
09/02/2022
addressed in third party footing inspection
Erosion Control Inspection Residential Passed 9/2/2022 09/02/2022
Misc
Resolved
09/02/2022
-Maintain gravel filter with min 6" lift of min 3/4" gravel -Clean debris from streets -Clean trash from lot
Plot Plan Inspection Passed 9/2/2022 09/02/2022
Driveway Inspection Passed 9/2/2022 09/02/2022
Misc
Informational
06/21/2022
On 6/21/2022 I performed a driveway inspection and pass the sub grade to pour concrete.
Sidewalk Inspection Passed 9/2/2022 09/02/2022
Misc
Informational
06/21/2022
On 6/21/2022 I performed a sidewalk inspection and pass the sub grade to pour concrete with dowels into the existing concrete to reduce expansion.
Occupancy Inspection - Codes Residential Failed 9/2/2022 9/2/2022 09/02/2022
Misc
Corrective Action Required
09/02/2022
-hardware at rear slider to be installed With 2 locking devices
Occupancy Inspection - Codes Residential Full C of O 9/7/2022 9/7/2022 09/07/2022
Misc
Resolved
09/07/2022
-hardware at rear slider to be installed With 2 locking devices
Documents & Images
Date Uploaded File Type Document Name
12/02/2021 RR #109 - PERMIT APP
12/02/2021 Approved Plans APPROVED PLANS
12/02/2021 Approved Plans APPROVED TRUSS LAYOUT
12/02/2021 Approved Plans APPROVED TRUSS PACKAGE 2
12/02/2021 Plot Plan APPROVED PLOT PLAN
12/03/2021 Permit Codes Residential Plan Review
12/06/2021 Permit DS Building Permit
12/06/2021 Receipt Receipt for transaction:2021-009105
12/30/2021 109 Reserve at Stoney Creek-FTNG
01/03/2022 Letter INSPECTION SUMMARY
01/25/2022 Letter INSPECTION SUMMARY
02/22/2022 Letter INSPECTION SUMMARY
02/22/2022 Letter INSPECTION SUMMARY
02/22/2022 Letter INSPECTION SUMMARY
04/28/2022 109 RESERVE AT STONEY CREEK LETTER
05/23/2022 Letter INSPECTION SUMMARY
05/23/2022 Letter INSPECTION SUMMARY
05/23/2022 Letter INSPECTION SUMMARY
05/23/2022 Letter INSPECTION SUMMARY
05/26/2022 Letter INSPECTION SUMMARY
05/26/2022 Letter INSPECTION SUMMARY
05/26/2022 Letter INSPECTION SUMMARY
06/21/2022 Letter INSPECTION SUMMARY
06/21/2022 Letter INSPECTION SUMMARY
09/02/2022 Letter INSPECTION SUMMARY
09/02/2022 Letter INSPECTION SUMMARY
09/02/2022 Letter INSPECTION SUMMARY
09/02/2022 Letter INSPECTION SUMMARY
09/02/2022 Letter INSPECTION SUMMARY
09/02/2022 Letter INSPECTION SUMMARY
09/07/2022 Letter Field Certificate of Occupancy
09/07/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home