Permit Application Status

PRRES20216144


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20216144
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - ROOF TRUSSES - COVERED DECK
11/29/2021
12/01/2021
08/12/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331504-EFHB Middle Big Creek, Full $468.72 $468.72 Paid 12/01/2021
8331507-Sewer Connection Fee $420.00 $420.00 Paid 12/01/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 12/01/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 12/01/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 12/01/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 12/01/2021
9110078-Valuation Fee New Single Family $1,099.36 $1,099.36 Paid 12/01/2021
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 08/03/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 1/5/2022 1/5/2022 01/05/2022
Misc
Informational
01/05/2022
APPROVED PER BRADLEY HUXOL 12/20/21
Underslab Plumbing Inspection - Residential Passed 1/12/2022 1/12/2022 01/12/2022
Erosion Control Inspection Residential Failed 1/12/2022 01/12/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
01/12/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -REPAIR SILT FENCE AT BACK OF LOT -CLEAN UP STREET
Sewer Service Inspection - R Passed 1/26/2022 01/26/2022
Water Service Inspection - R Passed 1/27/2022 (10:30) 1/27/2022 01/27/2022
Erosion Control Inspection Residential Failed 3/8/2022 3/8/2022 03/08/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
01/12/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. ADDRESS EROSION CONTROL ON LOT GRAVEL FILTER REQUIRED, MIN 6" LIFT 3/4" GRAVEL CLEAN ALL MUD FROM STREET
All Rough Inspection - Residential Failed 4/7/2022 4/7/2022 04/07/2022
Misc
Corrective Action Required
04/07/2022
-Install (2)2x10 deck header joist and connect to trimmer joists with hangers -Connect ducting to master bathroom fans -Complete master bathroom light electrical -Strap top plates lapped less than two ft above master tub -Install hangers for J9 trusses -Provide 2 stud support for B1 girder truss at refrigerator/stair wall; strap GT down to wall at this point -Tie down C5&6 trusses at mud exterior wall -Anchor rear basement wall sill plate within 12” of breaks (bedroom 3 and REC rm) -Support ducting above basement bedroom 3 -Fb basement bathroom/bedroom 3 wall from soffit; Fb floor penetration at plumbing trap -Plan calls for (3)2x10 above bedroom 3 window; plan calls for (2)2x12 above bedroom 4 window and (3)2x10 header at rear REC room wall -Over notched joist above basement bedroom 4 window **OK TO INSULATE -Install all doors and windows
Electrical Service Inspection Passed 4/7/2022 4/7/2022 04/07/2022
Gas Service Inspection - Residential Passed 4/7/2022 4/7/2022 04/07/2022
All Rough Inspection - Residential Failed 4/14/2022 4/14/2022 04/14/2022
Misc
Corrective Action Required
04/07/2022
-Install all doors and windows **OK TO INSULATE
Erosion Control Inspection Residential Partial 4/14/2022 4/14/2022 04/14/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
04/14/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. ADDRESS EROSION CONTROL ON LOT GRAVEL FILTER REQUIRED, MIN 6" LIFT 3/4" GRAVEL CLEAN ALL MUD FROM STREET
Driveway Inspection Partial 5/11/2022 5/11/2022 05/11/2022
Misc
Informational
05/11/2022
On 5.11.2022 I performed a driveway inspection and pass the sub-grade to pour concrete
Sidewalk Inspection Partial 5/11/2022 5/11/2022 05/11/2022
Misc
Informational
05/11/2022
On 5.11.2022 I performed a sidewalk inspection and pass the sub-grade to pour concrete
All Rough Inspection - Residential Passed 6/6/2022 6/6/2022 06/06/2022
Misc
Resolved
06/06/2022
Erosion Control Inspection Residential Partial 06/06/2022
Occupancy Inspection - Codes Residential Failed 7/29/2022 7/29/2022 07/29/2022
Misc
Corrective Action Required
07/29/2022
-FINAL DRIVEWAY AND SIDEWALK INSPECTIONS REQUIRED, CONTACT DEVELOPMENT SERVICES TO SCHEDULE -FINAL GRADE AND SOD -SPLASH BLOCKS -MAX 3/8" VARIANCE BETWEEN STAIRS RISES, SEE GARAGE STAIRS, IRC R311.7.5.1 -JACUZZI TUB MOTOR ACCESS REQUIRED, SEE IRC P2720.1
Sidewalk Inspection Passed 8/2/2022 8/2/2022 08/02/2022
Misc
Informational
05/11/2022
On 5.11.2022 I performed a sidewalk inspection and pass the sub-grade to pour concrete
Informational
08/02/2022
Sidewalk has been poured and appears to meet the standard ADA requirements.Steve Robbins 08/02/2022 2:25 PM
Driveway Inspection Passed 8/2/2022 8/2/2022 08/02/2022
Misc
Informational
05/11/2022
On 5.11.2022 I performed a driveway inspection and pass the sub-grade to pour concrete
Informational
08/02/2022
Driveway has been poured and appears to be ADA compiant. (SR)Steve Robbins 08/02/2022 2:31 PM
Occupancy Inspection - Codes Residential Ready for Temp CO 8/3/2022 8/3/2022 08/03/2022
Misc
Corrective Action Required
07/29/2022
-FINAL GRADE AND SOD -SPLASH BLOCKS
Occupancy Inspection - Codes Residential Temporary C of O 08/03/2022
Misc
Corrective Action Required
08/03/2022
-FINAL GRADE AND SOD -SPLASH BLOCKS
Erosion Control Inspection Residential Passed 08/12/2022
Piers/Caissons Inspection - Residential Passed 08/12/2022
Informational
08/12/2022
ON THIRD PARTY INSPECTION
Occupancy Inspection - Codes Residential Full C of O 8/12/2022 8/12/2022 08/12/2022
Misc
Resolved
08/12/2022
Documents & Images
Date Uploaded File Type Document Name
11/29/2021 RR #115 - PERMIT APP
11/30/2021 Approved Plans APPROVED PLANS
11/30/2021 Approved Plans APPROVED TRUSS LAYOUT
11/30/2021 Approved Plans APPROVED TRUSS PACKAGE
11/30/2021 Plot Plan APPROVED PLOT PLAN
12/01/2021 Permit Codes Residential Plan Review
12/01/2021 Permit DS Building Permit
12/01/2021 Receipt Receipt for transaction:2021-009029
01/04/2022 115 Reserve at Stoney Creek FTNG
01/05/2022 Letter INSPECTION SUMMARY
01/12/2022 Letter INSPECTION SUMMARY
01/12/2022 Letter INSPECTION SUMMARY
01/26/2022 Letter INSPECTION SUMMARY
01/27/2022 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
04/07/2022 Letter INSPECTION SUMMARY
04/07/2022 Letter INSPECTION SUMMARY
04/07/2022 Letter INSPECTION SUMMARY
04/11/2022 RR 115 Field Issue Letter
04/14/2022 Letter INSPECTION SUMMARY
04/14/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
05/11/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
07/29/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
08/02/2022 Letter INSPECTION SUMMARY
08/03/2022 Receipt Receipt for transaction:2022-006364
08/03/2022 Letter Codes Temporary Certificate of Occupancy
08/12/2022 Letter Codes Final Certificate of Occupancy
08/12/2022 Letter Field Certificate of Occupancy
08/12/2022 Letter INSPECTION SUMMARY
08/12/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home