Permit Application Status

PRRES20215871


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20215871
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. WALKOUT BASEMENT. COVERED DECK. ENGINEERED FLOOR SYSTEM - DEFERRED.
11/10/2021
12/03/2021
05/17/2022
11/07/2022
Locations
Contacts
JFE CONSTRUCTION INC, Address:1314 SW MARKET ST, Phone:(816) 470-0074  
Angie Mendenhall, Address:1314 SW Market Street  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
PERMITTING@JFECONSTRUCTION.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $540.00 $540.00 Paid 12/03/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 12/03/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 12/03/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 12/03/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 12/03/2021
9110078-Valuation Fee New Single Family $1,347.92 $1,347.92 Paid 12/03/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 12/22/2021 12/22/2021
Misc
Informational
12/22/2021
3rd party inspected.
Erosion Control Inspection Residential Failed 1/11/2022 01/11/2022
DCM5 ESC INSP DENIED
Corrective Action Required
01/11/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Underslab Plumbing Inspection - Residential Failed 1/11/2022 1/11/2022 01/11/2022
Misc
Corrective Action Required
01/11/2022
Inspection denied due to insufficient erosion control
Underslab Plumbing Inspection - Residential Passed 1/12/2022 1/12/2022 01/12/2022
Misc
Resolved
01/12/2022
Inspection denied due to insufficient erosion control
Sewer Service Inspection - R Passed 1/31/2022 (8:00) 1/31/2022 01/31/2022
Water Service Inspection - R Passed 2/16/2022 (8:00) 2/16/2022 02/16/2022
Water Service Inspection - R Failed 3/11/2022 03/11/2022
Misc
Corrective Action Required
03/11/2022
Water service shut off valve installed on wrong side of meter set. Back fill around meter well
Erosion Control Inspection Residential Failed 3/31/2022 03/31/2022
DCM5 ESC INSP DENIED
Resolved
03/31/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/31/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 03/31/2022 3:37 PM
Gas Service Inspection - Residential Failed 5/23/2022 5/23/2022 05/23/2022
Misc
Corrective Action Required
05/23/2022
Provide min. 10psi at pressure gauge for inspection.
Electrical Service Inspection Passed 5/23/2022 5/23/2022 05/23/2022
All Rough Inspection - Residential Failed 5/23/2022 5/23/2022 05/23/2022
Misc
Corrective Action Required
05/23/2022
-address rafters landing on blocks though out -fire block top of furr out wall in dining -address l bracket used for hanger above kitchen next to lvl -fireblock furr out under beam next to great room windows -address roof supports landing on non load bearing walls(office/bedroom) -missing joist hanger above basement stairs -seal/fireblock bed 4 E wall into furr down -seal/fireblock bed 4 to bath wall into furr down -fireblock dead space to furr down in great room basement -fireblock dead space at wet bar - 2x4’s furr down in wet bar requires joist hangers -fire block furred out wall to furr down in bath near wet bar -seal penetrations In joist space used for RA near above area -provide minimum 10psi at gas gauge for inspection -upload I-joist plans for inspection -cs-pf per plans
All Rough Inspection - Residential Failed 5/27/2022 5/27/2022 05/27/2022
Misc
Corrective Action Required
05/23/2022
-address rafters landing on blocks though out -address l bracket used for hanger above kitchen next to lvl -seal/fireblock bed 4 to bath wall into furr down(when using Unfaced insulation must be packed tight and secured) -fireblock dead space at wet bar (when using Unfaced insulation must be packed tight and secured) -fire block furred out wall to furr down in bath near wet bar(when using Unfaced insulation must be packed tight and secured)
Gas Service Inspection - Residential Passed 5/27/2022 5/27/2022 05/27/2022
Misc
Resolved
05/27/2022
Provide min. 10psi at pressure gauge for inspection.
All Rough Inspection - Residential Failed 6/1/2022 6/1/2022 06/01/2022
Misc
Corrective Action Required
05/27/2022
-address rafters landing on blocks though out -address l bracket used for hanger above kitchen next to lvl
Driveway Inspection Partial 7/7/2022 7/7/2022 07/07/2022
Misc
Informational
07/07/2022
On 7.7.2022 I performed a driveway inspection and pass the sub-grade to pour concrete.
Sidewalk Inspection Partial 7/7/2022 7/7/2022 07/07/2022
Misc
Informational
07/07/2022
On 7.7.2022 I performed a sidewalk inspection and pass the sub-grade to pour concrete.
Driveway Inspection Passed 7/18/2022 7/18/2022 07/18/2022
Misc
Informational
07/07/2022
On 7.7.2022 I performed a driveway inspection and pass the sub-grade to pour concrete. 7-18-22 RH. Driveway met LS and ADA specification.
Sidewalk Inspection Passed 7/18/2022 7/18/2022 07/18/2022
Misc
Informational
07/07/2022
On 7.7.2022 I performed a sidewalk inspection and pass the sub-grade to pour concrete. 7-18-22 RH. Sidewalk met LS and ADA Specification.
All Rough Inspection - Residential Failed 10/21/2022 10/21/2022
Misc
Resolved
10/21/2022
-address rafters landing on blocks though out -address l bracket used for hanger above kitchen next to lvl
All Rough Inspection - Residential Passed 10/21/2022 10/21/2022
Piers/Caissons Inspection - Residential Passed 10/21/2022 10/21/2022
Water Service Inspection - R Passed 10/21/2022 10/21/2022
Misc
Resolved
10/21/2022
Water service shut off valve installed on wrong side of meter set. Back fill around meter well
Occupancy Inspection - Codes Residential Failed 10/21/2022 10/21/2022 10/21/2022
Misc
Corrective Action Required
10/21/2022
-obtain lawn irrigation permit -final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -check water meter at time of final grade and sod -address to be properly illuminated -hardware at rear sliders -fire blocking for engineered I joist in unfinished spaces -security screws at rear basement door
Erosion Control Inspection Residential Passed 11/7/2022 11/07/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
11/07/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 03/31/2022 3:37 PM
Plot Plan Inspection Passed 11/7/2022 11/07/2022
Occupancy Inspection - Codes Residential Full C of O 11/7/2022 11/7/2022 11/07/2022
Misc
Resolved
11/07/2022
-obtain lawn irrigation permit -final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -check water meter at time of final grade and sod -address to be properly illuminated -hardware at rear sliders -fire blocking for engineered I joist in unfinished spaces -security screws at rear basement door
Documents & Images
Date Uploaded File Type Document Name
11/10/2021 HF 66 - Permit App
11/10/2021 HF 66 - Tax App
11/18/2021 Permit Codes Residential Plan Review
11/19/2021 Plot Plan APPROVED PLOT PLAN
11/19/2021 Approved Plans APPROVED DRAWINGS
11/19/2021 Permit Codes Residential Plan Review
12/03/2021 Permit DS Building Permit
12/03/2021 Receipt Receipt for transaction:2021-009082
12/21/2021 2034 SW Red Barn Ln LSMO Hook Farm Lot 66 JFE P 2021-5871 Footing Inspection Report
12/22/2021 Letter INSPECTION SUMMARY
01/11/2022 Letter INSPECTION SUMMARY
01/11/2022 Letter INSPECTION SUMMARY
01/12/2022 Letter INSPECTION SUMMARY
01/31/2022 Letter INSPECTION SUMMARY
02/09/2022 2034 Red Barn Rd_ALL SLAB INSP_2022-02-08
02/16/2022 Letter INSPECTION SUMMARY
03/11/2022 Letter INSPECTION SUMMARY
03/31/2022 Letter INSPECTION SUMMARY
05/23/2022 Letter INSPECTION SUMMARY
05/23/2022 Letter INSPECTION SUMMARY
05/23/2022 Letter INSPECTION SUMMARY
05/23/2022 Approved Plans APPROVED JOIST DRAWINGS
05/27/2022 Letter INSPECTION SUMMARY
05/27/2022 Letter INSPECTION SUMMARY
06/01/2022 Letter INSPECTION SUMMARY
07/18/2022 Letter INSPECTION SUMMARY
07/18/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
10/03/2022 2034 Red Barn Lane_Framing Evaluation Report_10-3-22
10/21/2022 Letter INSPECTION SUMMARY
10/21/2022 Letter INSPECTION SUMMARY
10/21/2022 Letter INSPECTION SUMMARY
10/21/2022 Letter INSPECTION SUMMARY
10/21/2022 Letter INSPECTION SUMMARY
11/07/2022 Letter INSPECTION SUMMARY
11/07/2022 Letter Field Certificate of Occupancy
11/07/2022 Letter Codes Final Certificate of Occupancy
11/07/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home